Influence of cavity dimensions and their derivatives (volume and 'C' factor) on shrinkage stress development and microleakage of composite restorations

被引:114
|
作者
Braga, Roberto R.
Boaro, Leticia C. C.
Kuroe, Toshifumi
Azeuedo, Caio L. N.
Singer, Julio M.
机构
[1] Univ Sao Paulo, Dept Dent Mat, FOUSP, Sch Dent, BR-05508900 Sao Paulo, Brazil
[2] Hokuriku Univ, Grad Sch Dent Med, Div Oral Hlth Sci, Dept Gerodontol, Sapporo, Hokkaido, Japan
[3] Univ Sao Paulo, Inst Math & Stat, Dept Stat, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
resin composite; polymerization stress; microleakage;
D O I
10.1016/j.dental.2005.11.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. To determine, in vitro, the influence of cavity dimensions on shrinkage stress development and microleakage of composite restorations. Methods. Cylindrical cavities with 2,3,4 or 6 mm diameter and 1 or 2 mm depth were prepared in bovine incisors (with enamel margins) and reproduced in photoelastic resin. Cavities were restored in bulk (Single Bond + Filtek Z250). Stress fringes were analyzed 10 min after photoactivation. Restored teeth were stored for 24 h, coated with nail polish and immersed in 50% AgNO3 for 2 h, followed by 6 h in developing solution. Specimens were sectioned twice and microleakage was measured under 20x magnification. Photoelastic data were analyzed descriptively only, due to lack of variability in some groups. Microleakage was analyzed through (generalized linear) regression models. Pearson correlation coefficients were computed to evaluate the relationship between microleakage and 'C' factor or volume. Results. Fringe order was higher at the internal angles than at the margins of the restorations. There was a trend for higher fringe orders with increasing diameter and depths. Regression analysis revealed a significant influence of restoration depth for diameters above 2 mm. The effect of diameter on microleakage is significantly higher (p < 0.0001) for 2-mm deep restorations, compared to those 1-mm deep. Pearson correlation coefficients suggest some relationship between microleakage and volume (r = 0.724, p < 0.0001), but not between microleakage and 'C' factor (r = 0.048, p = 0.6120). Conclusions. Shrinkage stress and microleakage were higher in restorations with larger diameters and depths. Microleakage seemed to be related to a restoration's volume, but not to its 'C' factor. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 7 条
  • [1] Influence of cavity dimensions, insertion technique and adhesive system on microleakage of Class V restorations
    Pfeifer, CSC
    Braga, RR
    Cardoso, PEC
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2006, 137 (02) : 197 - 202
  • [2] Influence of filling techniques on shrinkage stress in dental composite restorations
    Costa Oliveira, Karla Mychellyne
    Rocha Acosta Lancellotti, Ailla Carla
    Ccahuana-Vasquez, Renzo Alberto
    Consani, Simonides
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (01) : 53 - 60
  • [3] Influence of specimen dimensions and their derivatives (C-factor and volume) on polymerization stress determined in a high compliance testing system
    Boaro, Leticia C. C.
    Meira, Josete B. C.
    Ballester, Rafael Y.
    Braga, Roberto R.
    DENTAL MATERIALS, 2013, 29 (10) : 1034 - 1039
  • [4] Impact of Quantity of Resin, C-factor, and Geometry on Resin Composite Polymerization Shrinkage Stress in Class V Restorations
    Borges, A. L. S.
    Borges, A. B.
    Xavier, T. A.
    Bottino, M. C.
    Platt, J. A.
    OPERATIVE DENTISTRY, 2014, 39 (02) : 144 - 151
  • [5] Axial shrinkage-stress depends upon both C-factor and composite mass
    Watts, David C.
    Satterthwaite, Julian D.
    DENTAL MATERIALS, 2008, 24 (01) : 1 - 8
  • [6] Experimental and FE displacement and polymerization stress of bonded restorations as a function of the C-Factor, volume and substrate stiffness
    Cidreira Boaro, Leticia Cristina
    Brandt, William Cunha
    Cruz Meira, Josete Barbosa
    Rodrigues, Flavia Pires
    Palin, William M.
    Braga, Roberto Ruggiero
    JOURNAL OF DENTISTRY, 2014, 42 (02) : 140 - 148
  • [7] Degree of Conversion and Contraction Stress Development of a Resin Composite Irradiated Using Halogen and LED at Two C-factor Levels
    Cunha, L. G.
    Alonso, R. C. B.
    Neves, A. C. C.
    de Goes, M. F.
    Ferracane, J. L.
    Sinhoreti, M. A. C.
    OPERATIVE DENTISTRY, 2009, 34 (01) : 24 - 31