Feasibility and value of fully 3D Monte Carlo reconstruction in single-photon emission computed tomography

被引:12
|
作者
Lazaro, D
Breton, V
Buvat, I
机构
[1] Univ Clermont Ferrand, CNRS, IN2P3, Phys Corpusculaire Lab, F-63177 Aubiere, France
[2] CHU Pitie Salpetriere, INSERM, U494, F-75634 Paris, France
关键词
single photon emission computed tomography; Monte Carlo simulation; image reconstruction; 3D imaging;
D O I
10.1016/j.nima.2004.03.119
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accuracy of Single-Photon Emission Computed Tomography images is degraded by physical effects, namely photon attenuation, Compton scatter and spatially varying collimator response. The 3D nature of these effects is usually neglected by the methods used to correct for these effects. To deal with the 3D nature of the problem, a 3D projector modeling the spread of photons in 3D can be used in iterative tomographic reconstruction. The 3D projector can be estimated analytically with some approximations, or using precise Monte Carlo simulations. This latter approach has not been applied to fully 3D reconstruction yet due to impractical storage and computation time. The goal of this paper was to determine the gain to be expected from fully 3D Monte Carlo (F3DMC) modeling of the projector in iterative reconstruction, compared to conventional 2D and 3D reconstruction methods. As a proof-of-concept, two small datasets were considered. The projections of the two phantoms were simulated using the Monte Carlo simulation code GATE, as well as the corresponding projector, by taking into account all physical effects (attenuation, scatter, camera point spread function) affecting the imaging process. F3DMC was implemented by using this 3D projector in a maximum likelihood expectation maximization (MLEM) iterative reconstruction. To assess the value of F3DMC, data were reconstructed using four methods: filtered backprojection, MLEM without attenuation correction (MLEM), MLEM with attenuation correction, Jaszczak scatter correction and 3D correction for depth-dependent spatial resolution using an analytical model (MLEMC) and F3DMC. Our results suggest that F3DMC improves mainly imaging sensitivity and signal-to-noise ratio (SNR): sensitivity is multiplied by about 10(3) and SNR is increased by 20-70% compared to MLEMC. Computation of a more robust projector and application of the method on more realistic datasets are currently under investigation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [41] Scintigraphic demonstration of myocardial sarcoidosis: The added value of single-photon emission computed tomography
    Barneveld, PC
    vanLeeuwen, C
    vanIsselt, JW
    JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (03) : 256 - 257
  • [42] VALUE OF SINGLE-PHOTON EMISSION-COMPUTED TOMOGRAPHY IN ACUTE STROKE THERAPEUTIC TRIALS
    HANSON, SK
    GROTTA, JC
    RHOADES, H
    TRAN, HD
    LAMKI, LM
    BARRON, BJ
    TAYLOR, WJ
    STROKE, 1993, 24 (09) : 1322 - 1329
  • [43] Scintigraphic demonstration of myocardial sarcoidosis: The added value of single-photon emission computed tomography
    Peter C. Barneveld
    Carlos van Leeuwen
    Johannes W. van Isselt
    Journal of Nuclear Cardiology, 1997, 4 : 256 - 257
  • [44] Single-photon Emission Tomography/Computed Tomography Delineation of Freiberg Infraction
    Currie, Geoffrey M.
    O'Loughlin, Samantha
    Mahmood, Ume Rubabb
    Haase, Matthew
    Hashmi, Rashid
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2014, 45 (02) : 137 - 140
  • [45] Monitoring jaw osteomyelitis therapy with single-photon emission computed tomography/computed tomography
    Heimann, Ilsedore
    Kuttenberger, Johannes
    della Chiesa, Andrea
    Bhure, Ujwal
    del Sol Perez-Lago, Maria
    Roos, Justus E.
    Lima, Thiago V. M.
    Strobel, Klaus
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (01) : 51 - 57
  • [46] The Role of Single-Photon Emission Computed Tomography and SPECT/Computed Tomography in Oncologic Imaging
    Brandon, David
    Alazraki, Adina
    Halkar, Raghuveer K.
    Alazraki, Naomi P.
    SEMINARS IN ONCOLOGY, 2011, 38 (01) : 87 - 108
  • [47] Depiction of ventriculoperitoneal shunt obstruction with single-photon emission computed tomography/computed tomography
    Aksoy, Sabire Yilmaz
    Vatankulu, Betul
    Uslu, Lebriz
    Halac, Metin
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2016, 31 (03): : 246 - +
  • [48] Diagnosis of a Lymphoenteric Fistula by Single-Photon Emission Computed Tomography/Computed Tomography Lymphoscintigraphy
    Anantharachagan, Ariharan
    ACG CASE REPORTS JOURNAL, 2020, 7 (06)
  • [49] Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma
    Schillaci, Orazio
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 275 - 285
  • [50] Utility of single-photon emission computed tomography and computed tomography imaging in bone infarction
    Russo, Barbara
    Jose Martin-Marcuartu, Juan
    de Bonilla-Damia, Alvaro
    Garcia-Jimenez, Rosario
    REUMATOLOGIA CLINICA, 2019, 15 (06): : E136 - E137