Feasibility and value of fully 3D Monte Carlo reconstruction in single-photon emission computed tomography

被引:12
|
作者
Lazaro, D
Breton, V
Buvat, I
机构
[1] Univ Clermont Ferrand, CNRS, IN2P3, Phys Corpusculaire Lab, F-63177 Aubiere, France
[2] CHU Pitie Salpetriere, INSERM, U494, F-75634 Paris, France
关键词
single photon emission computed tomography; Monte Carlo simulation; image reconstruction; 3D imaging;
D O I
10.1016/j.nima.2004.03.119
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accuracy of Single-Photon Emission Computed Tomography images is degraded by physical effects, namely photon attenuation, Compton scatter and spatially varying collimator response. The 3D nature of these effects is usually neglected by the methods used to correct for these effects. To deal with the 3D nature of the problem, a 3D projector modeling the spread of photons in 3D can be used in iterative tomographic reconstruction. The 3D projector can be estimated analytically with some approximations, or using precise Monte Carlo simulations. This latter approach has not been applied to fully 3D reconstruction yet due to impractical storage and computation time. The goal of this paper was to determine the gain to be expected from fully 3D Monte Carlo (F3DMC) modeling of the projector in iterative reconstruction, compared to conventional 2D and 3D reconstruction methods. As a proof-of-concept, two small datasets were considered. The projections of the two phantoms were simulated using the Monte Carlo simulation code GATE, as well as the corresponding projector, by taking into account all physical effects (attenuation, scatter, camera point spread function) affecting the imaging process. F3DMC was implemented by using this 3D projector in a maximum likelihood expectation maximization (MLEM) iterative reconstruction. To assess the value of F3DMC, data were reconstructed using four methods: filtered backprojection, MLEM without attenuation correction (MLEM), MLEM with attenuation correction, Jaszczak scatter correction and 3D correction for depth-dependent spatial resolution using an analytical model (MLEMC) and F3DMC. Our results suggest that F3DMC improves mainly imaging sensitivity and signal-to-noise ratio (SNR): sensitivity is multiplied by about 10(3) and SNR is increased by 20-70% compared to MLEMC. Computation of a more robust projector and application of the method on more realistic datasets are currently under investigation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [31] Single-photon emission computed tomography-computed tomography in imaging infection
    Navalkissoor, Shaunak
    Nowosinska, Ewa
    Gnanasegaran, Gopinath
    Buscombe, John R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (04) : 283 - 290
  • [32] Targeted Fully 3D Monte Carlo Reconstruction in SPECT
    El Bitar, Ziad
    Petegnief, Yolande
    Hill, David
    Breton, Vincent
    Buvat, Irene
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3410 - 3413
  • [33] Technological development and advances in single-photon emission computed tomography/computed tomography
    Seo, Youngho
    Mari, Carina
    Hasegawa, Bruce H.
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 177 - 198
  • [34] Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography
    Kamphuis C.
    Beekman F.J.
    Van Rijk P.P.
    Viergever M.A.
    European Journal of Nuclear Medicine, 1998, 25 (1) : 8 - 18
  • [35] Synergistic value of single-photon emission computed tomography/computed tomography fusion to radioimmunoscintigraphic imaging of prostate cancer
    Sodee, D. Bruce
    Sodee, Adriane E.
    Bakale, George
    SEMINARS IN NUCLEAR MEDICINE, 2007, 37 (01) : 17 - 28
  • [36] The Economic Value of Hybrid Single-photon Emission Computed Tomography With Computed Tomography Imaging in Pulmonary Embolism Diagnosis
    Toney, Lauren K.
    Kim, Richard D.
    Palli, Swetha R.
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1110 - 1123
  • [37] Imaging gliomas with positron emission tomography and single-photon emission computed tomography
    Bénard, F
    Romsa, J
    Hustinx, R
    SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (02) : 148 - 162
  • [38] RAPIDLY CONVERGING ITERATIVE RECONSTRUCTION ALGORITHMS IN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    WALLIS, JW
    MILLER, TR
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (10) : 1793 - 1800
  • [39] NEURAL-NETWORK RECONSTRUCTION OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGES
    KERR, JP
    BARTLETT, EB
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (03) : 116 - 126
  • [40] Evaluation of reconstruction techniques for lung single photon emission tomography: A Monte Carlo study
    Norberg, Pernilla
    Bakeb, Bjorn
    Jacobsson, Lars
    Carlsson, Gudrun Alm
    Gustafsson, Agnetha
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (12) : 929 - 936