Feasibility and value of fully 3D Monte Carlo reconstruction in single-photon emission computed tomography

被引:12
|
作者
Lazaro, D
Breton, V
Buvat, I
机构
[1] Univ Clermont Ferrand, CNRS, IN2P3, Phys Corpusculaire Lab, F-63177 Aubiere, France
[2] CHU Pitie Salpetriere, INSERM, U494, F-75634 Paris, France
关键词
single photon emission computed tomography; Monte Carlo simulation; image reconstruction; 3D imaging;
D O I
10.1016/j.nima.2004.03.119
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accuracy of Single-Photon Emission Computed Tomography images is degraded by physical effects, namely photon attenuation, Compton scatter and spatially varying collimator response. The 3D nature of these effects is usually neglected by the methods used to correct for these effects. To deal with the 3D nature of the problem, a 3D projector modeling the spread of photons in 3D can be used in iterative tomographic reconstruction. The 3D projector can be estimated analytically with some approximations, or using precise Monte Carlo simulations. This latter approach has not been applied to fully 3D reconstruction yet due to impractical storage and computation time. The goal of this paper was to determine the gain to be expected from fully 3D Monte Carlo (F3DMC) modeling of the projector in iterative reconstruction, compared to conventional 2D and 3D reconstruction methods. As a proof-of-concept, two small datasets were considered. The projections of the two phantoms were simulated using the Monte Carlo simulation code GATE, as well as the corresponding projector, by taking into account all physical effects (attenuation, scatter, camera point spread function) affecting the imaging process. F3DMC was implemented by using this 3D projector in a maximum likelihood expectation maximization (MLEM) iterative reconstruction. To assess the value of F3DMC, data were reconstructed using four methods: filtered backprojection, MLEM without attenuation correction (MLEM), MLEM with attenuation correction, Jaszczak scatter correction and 3D correction for depth-dependent spatial resolution using an analytical model (MLEMC) and F3DMC. Our results suggest that F3DMC improves mainly imaging sensitivity and signal-to-noise ratio (SNR): sensitivity is multiplied by about 10(3) and SNR is increased by 20-70% compared to MLEMC. Computation of a more robust projector and application of the method on more realistic datasets are currently under investigation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [1] Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study
    Lazaro, D
    El Bitar, Z
    Breton, V
    Hill, D
    Buvat, I
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3739 - 3754
  • [2] The Value of Single-photon Emission Computed Tomography/Computed Tomography in the Evaluation of Herniation Pits
    Graham-Thompson, Jessica
    Brayshaw, Grace
    Currie, Geoffrey M.
    Greene, Lacey
    Haase, Matthew
    Hashmi, Rashid
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (01) : 108 - 112
  • [3] Is Single-Photon Emission Computed Tomography/Computed Tomography Superior to Single-Photon Emission Computed Tomography in Assessing Unilateral Condylar Hyperplasia?
    Liu, Pingan
    Shi, Jun
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (06) : 1279.e1 - 1279.e7
  • [4] Single-photon emission computed tomography/computed tomography in endocrinology
    Krausz, Yodphat
    Israel, Ora
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 267 - 274
  • [5] SINGLE-PHOTON TRACERS FOR SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    KUNG, HF
    ACADEMIC RADIOLOGY, 1995, 2 : S94 - S95
  • [6] Feasibility study on image reconstruction for single-photon emission computed tomography with limited projections by neural networks
    Yamauchi, Ryota
    Tamaki, Shingo
    Morizane, Yuri
    Kusaka, Sachie
    Manabe, Yuichiro
    Akiyama, Yoko
    Sato, Fuminobu
    Murata, Isao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 986
  • [8] Fully Bayesian reconstructions from single-photon emission computed tomography data
    Weir, IS
    JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1997, 92 (437) : 49 - 60
  • [9] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    KNOLL, GF
    PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 320 - 329
  • [10] Single-photon emission computed tomography in neurotherapeutics
    Devous Sr. M.D.
    NeuroRX, 2005, 2 (2): : 237 - 249