An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

被引:43
|
作者
Paniagua Gonzalez, Gema [1 ]
Fernandez Hernando, Pilar [1 ]
Durand Alegria, J. S. [1 ]
机构
[1] Univ Nacl Educ Distancia, Fac Ciencias, Dept Ciencias Analit, E-28040 Madrid, Spain
关键词
Molecularly imprinted polymer; Affinity membrane; Digoxin; Organic sample analysis; ADSORPTION; EXTRACTION;
D O I
10.1016/j.aca.2009.02.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10(-3) mg L-1. The detection limit was 3.17 x 10(-5) mg L-1. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10(-3) mg L-1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [21] Designing of molecularly imprinted polymer-based potentiometric sensor for the determination of heparin
    Li, Lifeng
    Liang, Yizeng
    Liu, Youcai
    ANALYTICAL BIOCHEMISTRY, 2013, 434 (02) : 242 - 246
  • [22] A novel electrochemical sensor based on a molecularly imprinted polymer for the determination of epigallocatechin gallate
    Liu, Yanrui
    Zhu, Lili
    Hu, Yue
    Peng, Xinsheng
    Du, Jiangyan
    FOOD CHEMISTRY, 2017, 221 : 1128 - 1134
  • [23] A novel electrochemical sensor based on electropolymerized molecularly imprinted polymer for determination of luteolin
    Wei, Meiting
    Geng, Xue
    Liu, Yanrui
    Long, Hongyan
    Du, Jiangyan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 842 : 184 - 192
  • [24] Molecularly imprinted polymer based electrochemical sensor for the determination of the anthelmintic drug oxfendazole
    Radi, Abd-Elgawad
    El-Naggar, Abd-Elrahman
    Nassef, Hossam M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 729 : 135 - 141
  • [25] A biomimetic potentiometric sensor based on molecularly imprinted polymer for the determination of memantine in tablets
    Arvand, Majid
    Samie, Hedyeh Asadi
    DRUG TESTING AND ANALYSIS, 2013, 5 (06) : 461 - 467
  • [26] Determination of Diuron by Using Electrochemical Sensor Based on Molecularly Imprinted Polymer Film
    Ondes, Baha
    Soysal, Mert
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B395 - B401
  • [27] An electrochemical sensor based on a molecularly imprinted polymer for determination of anticancer drug Mitoxantrone
    Liu, Yanrui
    Wei, Meiting
    Hu, Yue
    Zhu, Lili
    Du, Jiangyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 544 - 551
  • [28] Electrochemical sensor for dodecyl gallate determination based on electropolymerized molecularly imprinted polymer
    Pedroso, Mariele Mucio
    Foguel, Marcos Vinicius
    Siqueira Silva, Dulce Helena
    Taboada Sotomayor, Maria del Pilar
    Yamanaka, Hideko
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 : 180 - 186
  • [29] Preparation of a Molecularly Imprinted Polymer Nanotubes Membrane and Its Application in the Determination of Catecholamines in Urine Samples
    Qiu Xiuzhen
    Hua Yongbiao
    Guo Huishi
    Lu Wenguan
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2018, 39 (04): : 653 - 659
  • [30] SELECTIVE CHEMICAL SENSOR BASED ON MOLECULARLY IMPRINTED POLYMER TO DETECT ISOBORNEOL IN AQUEOUS SAMPLES
    Braga, Guilherme S.
    Lieberzeit, Peter A.
    Fonseca, Fernando J.
    2017 ICOCS/IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2017), 2017,