Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes

被引:44
作者
Chen, Xu [1 ]
Yuan, Fei [1 ]
Wu, Lianqun [2 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Ophthalmol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Ophthalmol, Shanghai, Peoples R China
关键词
IN-SITU KERATOMILEUSIS; AMERICAN SOCIETY; CATARACT-SURGERY; ADJUSTMENT; BIOMETRY; FORMULA;
D O I
10.1016/j.jcrs.2015.12.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the accuracy of intraocular lens (IOL) power calculation methods after laser refractive surgery in myopic eyes, a comprehensive literature search was carried out for retrospective case series studies with data on post-myopic laser surgery IOL power calculations published from January 2000 to May 2014. A metaanalysis of the 9 identified studies was performed using odds ratios in percentage of prediction error within +/- 0.5 or 1.0 diopter (D) of the target refraction. Compared with the Haigis-L method, the clinical history method, corneal bypass method, and Feiz-Mannis method were associated with lower odds of predication; the Masket method showed higher odds. The subgroup data showed significantly better performance of the Shammas no-history method with the Shammas post-LASIK formula than the Haigis-L method in predication error. The Masket method and the Shammas no-history method with the Shammas post-LASIK formula without historical data had more prediction accuracy than the Haigis-L method. The clinical history method, Feiz-Mannis method, and corneal bypass method, which required historical data, were less accurate in their predictions.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 38 条
[1]  
[Anonymous], REVMAN
[2]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[3]   Comparison of IOL Power Calculation Methods and Intraoperative Wavefront Aberrometer in Eyes After Refractive Surgery [J].
Canto, Ana Paula ;
Chhadva, Priyanka ;
Cabot, Florence ;
Galor, Anat ;
Yoo, Sonia H. ;
Vaddavalli, Pravin K. ;
Culbertson, William W. .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (07) :484-489
[4]  
Chen Xu, 2010, Zhonghua Yan Ke Za Zhi, V46, P518
[5]   A Comparison of the American Society of Cataract and Refractive Surgery post-myopic LASIK/PRK Intraocular Lens (IOL) calculator and the Ocular MD IOL calculator [J].
DeMill, David L. ;
Moshirfar, Majid ;
Neuffer, Marcus C. ;
Hsu, Maylon ;
Sikder, Shameema .
CLINICAL OPHTHALMOLOGY, 2011, 5 :1409-1414
[6]   Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia - A standardized approach [J].
Feiz, V ;
Mannis, MJ ;
Garcia-Ferrer, F ;
Kandavel, G ;
Darlington, JK ;
Kim, E ;
Caspar, J ;
Wang, JL ;
Wang, W .
CORNEA, 2001, 20 (08) :792-797
[7]   Intraocular Lens Power Adjustment After Myopic Excimer Laser Surgery: Validation Studies for Geggel Ratio and Consensus Group [J].
Geggel, Harry S. .
CORNEA, 2013, 32 (07) :1009-1014
[8]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[9]  
Haigis W., 2004, Intraocular Lens Power Calculations, P41
[10]   Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula [J].
Haigis, Wolfgang .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1658-1663