A reversible fluorescence "off-on-off" sensor for sequential detection of aluminum and acetate/fluoride ions

被引:361
作者
Gupta, Vinod Kumar [1 ,2 ,3 ]
Mergu, Naveen [1 ]
Kumawat, Lokesh Kumar [1 ]
Singh, Ashok Kumar [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[3] Univ Johannesburg, Dept Appl Chem, Johannesburg, South Africa
关键词
Chemosensor; Fluorescence; Reversibility; Sequential detection; Metal ion; Anion; NAKED-EYE DETECTION; VOLTAMMETRIC DETERMINATION; COLORIMETRIC SENSOR; AQUEOUS-MEDIA; TRACE AMOUNTS; FLUORIDE; CHEMOSENSOR; RECOGNITION; ANIONS; MERCURY;
D O I
10.1016/j.talanta.2015.05.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new rhodamine functionalized fluorogenic Schiff base CS was synthesized and its colorimetric and fluorescence responses toward various metal ions were explored. The sensor exhibited highly selective and sensitive colorimetric and "off-on" fluorescence response towards Al3+ in the presence of other competing metal ions. These spectral changes are large enough in the visible region of the spectrum and thus enable naked-eye detection. Studies proved that the formation of CS-Al3+ complex is fully reversible and can sense to AcO-/F- via dissociation. The results revealed that the sensor provides fluorescence "off-on-off' strategy for the sequential detection of Al3+ and AcO-/F-. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 67 条
[1]   An integrated system of pyrene and rhodamine-6G for selective colorimetric and fluorometric sensing of mercury(II) [J].
Ahamed, B. Nisar ;
Ghosh, Pradyut .
INORGANICA CHIMICA ACTA, 2011, 372 (01) :100-107
[2]  
Alamgir ANM, 2009, BANGL J BOT, V38, P1
[3]   Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection on-line derivatization and preconcentration [J].
Ali, A ;
Shen, H ;
Yin, XF .
ANALYTICA CHIMICA ACTA, 1998, 369 (03) :215-223
[4]   The significance of water ionic strength on aluminium toxicity in brown trout (Salmo trutta L.) [J].
Alstad, NEW ;
Kjelsberg, BM ;
Vollestad, LA ;
Lydersen, E ;
Poléo, ABS .
ENVIRONMENTAL POLLUTION, 2005, 133 (02) :333-342
[5]   Aluminium localization and toxicity symptoms related to root growth inhibition in rice (Oryza sativa L.) seedlings [J].
Alvim, M. N. ;
Ramos, F. T. ;
Oliveira, D. C. ;
Isaias, R. M. S. ;
Franca, M. G. C. .
JOURNAL OF BIOSCIENCES, 2012, 37 (06) :1079-1088
[6]   What anions do to N-H-containing receptors [J].
Amendola, Valeria ;
Esteban-Gomez, David ;
Fabbrizzi, Luigi ;
Licchelli, Maurizio .
ACCOUNTS OF CHEMICAL RESEARCH, 2006, 39 (05) :343-353
[7]   A simple structural hydrazide-based gelator as a fluoride ion colorimetric sensor [J].
Bai, Binglian ;
Ma, Jie ;
Wei, Jue ;
Song, Jianxi ;
Wang, Haitao ;
Li, Min .
ORGANIC & BIOMOLECULAR CHEMISTRY, 2014, 12 (21) :3478-3483
[8]   ALUMINUM-INDUCED NEUROTOXICITY - ALTERATIONS IN MEMBRANE-FUNCTION AT THE BLOOD-BRAIN-BARRIER [J].
BANKS, WA ;
KASTIN, AJ .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 1989, 13 (01) :47-53
[9]  
Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.3.CO
[10]  
2-G