The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis

被引:21
作者
Pecoraro, Valentina [1 ]
Petri, Davide [2 ]
Costantino, Giorgio [3 ]
Squizzato, Alessandro [4 ]
Moja, Lorenzo [5 ]
Virgili, Gianni [6 ]
Lucenteforte, Ersilia [2 ]
机构
[1] AUSL Modena, Dept Lab Med & Pathol, Osped Civile St Agostino Estense, Modena, Italy
[2] Univ Pisa, Dept Clin & Expt Med, Via Roma 10, I-56126 Pisa, Italy
[3] Univ Milan, Osped Maggiore Policlin, IRCCS Fdn Ca Granda, UOC Pronto Soccorso & Med DUrgenza, Milan, Italy
[4] Univ Insubria, Dept Med & Surg, Como, Italy
[5] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
[6] AOU Careggi, Dept Neurosci Psychol Drug Res & Child Hlth NEURO, Florence, Italy
关键词
Body temperature; Diagnostic tests; Fever; Systematic review; Thermometers; TEMPORAL ARTERY THERMOMETRY; RECTAL THERMOMETRY; TYMPANIC MEMBRANE; EAR THERMOMETRY; CLINICAL ACCURACY; SKIN THERMOMETER; CHILDREN YOUNGER; AXILLARY; FEVER; RELIABILITY;
D O I
10.1007/s11739-020-02556-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Not much is known about how accurate and reproducible different thermometers are at diagnosing patients with suspected fever. The study aims at evaluating which peripheral thermometers are more accurate and reproducible. We searched Medline, Embase, Scopus, WOS, CENTRAL, and Cinahl to perform: (1) diagnostic accuracy meta-analysis (MA) using rectal mercury-in-glass or digital thermometry as reference, and bivariate models for pooling; (2) network MA to estimate differences in mean temperature between devices; (3) Bland-Altman method to estimate 95% coefficient of reproducibility. PROSPERO registration: CRD42020174996. We included 46 studies enrolling more than 12,000 patients. Using 38 degrees C (100.4 degrees F) as cut-off temperature, temporal infrared thermometry had a sensitivity of 0.76 (95% confidence interval, 0.65, 0.84; low certainty) and specificity of 0.96 (0.92, 0.98; moderate certainty); tympanic infrared thermometry had a sensitivity of 0.77 (0.60, 0.88; low certainty) and specificity of 0.98 (0.95, 0.99; moderate certainty). For all the other index devices, it was not possible to pool the estimates. Compared to the rectal mercury-in-glass thermometer, mean temperature differences were not statistically different from zero for temporal or tympanic infrared thermometry; the median coefficient of reproducibility ranged between 0.53 degrees C [0.95 degrees F] for infrared temporal and 1.2 degrees C [2.16 degrees F] for axillary digital thermometry. Several peripheral thermometers proved specific, but not sensitive for diagnosing fever with rectal thermometry as a reference standard, meaning that finding a temperature below 38 degrees C does not rule out fever. Fixed differences between temperatures together with random error means facing differences between measurements in the order of 2 degrees C [4.5 degrees F]. This study informs practitioners of the limitations associated with different thermometers; peripheral ones are specific but not sensitive.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [21] The clock drawing test: A systematic review and meta-analysis of diagnostic accuracy
    Park, JinKyung
    Jeong, EunHye
    Seomun, GyeongAe
    JOURNAL OF ADVANCED NURSING, 2018, 74 (12) : 2742 - 2754
  • [22] Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis
    Alabousi, Mostafa
    Zha, Nanxi
    Salameh, Jean-Paul
    Samoilov, Lucy
    Sharifabadi, Anahita Dehmoobad
    Pozdnyakov, Alex
    Sadeghirad, Behnam
    Freitas, Vivianne
    McInnes, Matthew D. F.
    Alabousi, Abdullah
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2058 - 2071
  • [23] Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis
    Mostafa Alabousi
    Nanxi Zha
    Jean-Paul Salameh
    Lucy Samoilov
    Anahita Dehmoobad Sharifabadi
    Alex Pozdnyakov
    Behnam Sadeghirad
    Vivianne Freitas
    Matthew D. F. McInnes
    Abdullah Alabousi
    European Radiology, 2020, 30 : 2058 - 2071
  • [24] A systematic review, meta-analysis, and network analysis of diagnostic microRNAs in glaucoma
    Rezaei, Masoud
    Faramarzpour, Mahsa
    Shobeiri, Parnian
    Seyedmirzaei, Homa
    Sarasyabi, Mohammad Sharifi
    Dabiri, Shahriar
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [25] A systematic review, meta-analysis, and network analysis of diagnostic microRNAs in glaucoma
    Masoud Rezaei
    Mahsa Faramarzpour
    Parnian Shobeiri
    Homa Seyedmirzaei
    Mohammad Sharifi Sarasyabi
    Shahriar Dabiri
    European Journal of Medical Research, 28
  • [26] Diagnostic accuracy of lamellar body count as a predictor of fetal lung maturity: A systematic review and meta-analysis
    Abdou, Ahmed Mahmoud
    Badr, Mohammad S.
    Helal, Khaled F.
    Rafeek, Mohamed E.
    Abdelrhman, Amr A.
    Kotb, Mahmoud
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY-X, 2020, 5
  • [27] A Systematic Review and Meta-Analysis Comparing the Diagnostic Accuracy Tests of COVID-19
    Vilca-Alosilla, Juan Jeferson
    Candia-Puma, Mayron Antonio
    Coronel-Monje, Katiusca
    Goyzueta-Mamani, Luis Daniel
    Galdino, Alexsandro Sobreira
    Machado-de-Avila, Ricardo Andrez
    Giunchetti, Rodolfo Cordeiro
    Coelho, Eduardo Antonio Ferraz
    Chavez-Fumagalli, Miguel Angel
    DIAGNOSTICS, 2023, 13 (09)
  • [28] Accuracy of diagnostic tests for feline sporotrichosis: A systematic review and meta-analysis
    Domingos, Eric L.
    Souza, Dalton A.
    Alves, Fernando M. S.
    Gorski, Daniela
    Tonin, Fernanda S.
    Ferreira, Luana M.
    Pontarolo, Roberto
    ACTA TROPICA, 2025, 263
  • [29] Diagnostic accuracy of oral thermometry for fever detection in adult patients: literature review and meta-analysis
    Kiekkas, Panagiotis
    Aretha, Diamanto
    Tzenalis, Anastasios
    Stefanopoulos, Nikolaos
    JOURNAL OF CLINICAL NURSING, 2022, 31 (5-6) : 520 - 531
  • [30] A Systematic Review and Meta-Analysis of Dengue Risk with Temperature Change
    Fan, Jingchun
    Wei, Wanxia
    Bai, Zhenggang
    Fan, Chunling
    Li, Shulan
    Liu, Qiyong
    Yang, Kehu
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2015, 12 (01): : 1 - 15