Prospective 3D ultrasonographic evaluation of immediate postpartum urine retention volume in 100 women who delivered vaginally

被引:29
作者
Demaria, F
Amar, N
Biau, D
Fritel, X
Porcher, R
Amarenco, G
Madelenat, P
Benifla, JL
机构
[1] Hop Rothschild, Serv Gynecol Obstet, F-75571 Paris, France
[2] Hop St Louis, Dept Biostat & Med Informat, F-75010 Paris, France
[3] Hop Rothschild, Serv Reeduc Neurol & Explorat Perineales, F-75012 Paris, France
[4] Hop Bichat, Serv Gynecol Obstet, F-75018 Paris, France
关键词
3D ultrasound; delivery; immediate postpartum urine retention volume; pregnancy;
D O I
10.1007/s00192-004-1159-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Our objective was to determine the reproducibility and validity of urine retention volumes measured by 3D ultrasonography (3D-US) 2 h postpartum. This was a longitudinal prospective study of 100 women who delivered vaginally. Each woman underwent five successive urine retention measurements with the Bladder Scan 2 h after vaginal delivery, followed by transurethral catheterization to determine the real volume. The reproducibility of only the last four scan values was analyzed with an intraclass correlation coefficient, and that of determinations 4 and 5 with a Bland-Altman plot. The validity of the device was similarly evaluated using the mean four-scan and real values. Pearson's correlation coefficient was calculated and a least-trimmed squares robust linear-regression model was used. All tests were two-sided with a 5% alpha risk. Results showed that 3D-US measurements were highly reproducible, with an intraclass correlation coefficient of 0.974 (95% CI:0.964-0.981). 3D-US also accurately estimated the real urine volume (intraclass correlation coefficient 0.924; 95% CI:0.888-0.949), but tended to underestimate by about 6.8%. The between-technique Pearson correlation coefficient was 0.94 (P<0.0001) and the regression analysis gave an R-2 of 0.914. Urine retention volumes exceeded 500 ml in 55 women, and 1 l in 7. We concluded that 3D-US was reliably able to measure postpartum urine retention volume.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 24 条
[1]   Measurement of bladder volume following cesarean section using Bladderscan [J].
Barrington, JW ;
Edwards, G ;
Ashcroft, M ;
Adekanmi, O .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2001, 12 (06) :373-374
[2]   Locales: Supporting large multiuser virtual environments [J].
Barrus, JW ;
Waters, RC ;
Anderson, DB .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1996, 16 (06) :50-57
[3]   Portable ultrasound determination of urinary residual volume [J].
Bent A.E. ;
Nahhas D.E. ;
McLennan M.T. .
International Urogynecology Journal, 1997, 8 (4) :200-202
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Validation of an ultrasound scanner for determing urinary volumes in surgical patients and volunteers [J].
Brouwer, TA ;
Eindhoven, BG ;
Epema, AH ;
Henning, RH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (06) :379-385
[6]  
CASADO JS, 1996, ARCH ESPAN UROL, V49, P35
[7]  
Chan H, 1993, J Neurosci Nurs, V25, P309
[8]   THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME [J].
COOMBES, GM ;
MILLARD, RJ .
JOURNAL OF UROLOGY, 1994, 152 (06) :2083-2085
[9]  
Ding Y. Y., 1996, Singapore Medical Journal, V37, P365