A New Indirect Electroanalytical Method to Monitor the Contamination of Natural Waters with 4-Nitrophenol Using Multiwall Carbon Nanotubes

被引:52
作者
Moraes, Fernando Cruz [2 ]
Tanimoto, Sonia Tomie [1 ]
Salazar-Banda, Giancarlo Richard [1 ]
Spinola Machado, Sergio Antonio [1 ]
Mascaro, Lucia Helena [2 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbon nanotubes; Boron-doped diamond; Square-wave voltammetry; Electroanalysis; Environmental monitoring; PERFORMANCE LIQUID-CHROMATOGRAPHY; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; SQUARE-WAVE VOLTAMMETRY; P-NITROPHENOL; ELECTROCATALYTIC BEHAVIOR; ELECTROCHEMICAL OXIDATION; DIAMOND ELECTRODES; FLOW-INJECTION; 2-NITROPHENOL; PHENOLS;
D O I
10.1002/elan.200804522
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical detection of the hazardous pollutant 4-nitrophenol (4-NP) at low potentials, in order to avoid matrix interferences, is an important research challenge. This study describes the development, electrochemical characterization and utilization of a multiwall carbon nanotube (MWCNT) film electrode for the quantitative determination of 4-NP in natural water. Electrochemical impedence spectroscopy measurements showed that the modified surface exhibits a decrease of ca. 13 times in the charge transfer resistance when compared with a bare glassy carbon (GC) surface. Voltammetric experiments showed the possibility to oxidize a hydroxylamine layer (produced by the electrochemical reduction of 4-NP on the GC/MWNCT surface) in a potential region which is approximately 700 mV less positive than that needed to oxidize 4-NP, thus minimizing the interference of matrix components. The limit of detection for 4-NP obtained using square-wave voltammetry (0.12 mu mol L-1) was lower than the value advised by EPA. A natural water sample from a dam located in Sao Carlos (Brazil) was spiked with 4-NP and analyzed by the standard addition method using thee GC/MWCNT electrode, without any further purification step. the recovery procedure yielded a value of 96.5% for such sample, thus confirming the suitability of the developed method to determine 4-NP in natural water samples. The electrochemical determination was compared with that obtained by HPLC with UV-vis detection.
引用
收藏
页码:1091 / 1098
页数:8
相关论文
共 40 条
[1]   DETERMINATION OF 2-NITROPHENOL, 4-NITROPHENOL, 2-METHOXY-5-NITROPHENOL, AND 2,4-DINITROPHENOL BY DIFFERENTIAL-PULSE VOLTAMMETRY AND ADSORPTIVE STRIPPING VOLTAMMETRY [J].
BAREK, J ;
EBERTOVA, H ;
MEJSTRIK, V ;
ZIMA, J .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1994, 59 (08) :1761-1771
[2]   Competitive electrochemical oxidation of p-chlorophenol and p-nitrophenol on Bi-doped PbO2 [J].
Borras, C ;
Laredo, T ;
Scharifker, BR .
ELECTROCHIMICA ACTA, 2003, 48 (19) :2775-2780
[3]  
BRDICKA R, 1944, CHEM LISTY, V38, P252
[4]   DETERMINATION OF PHENOL, M-CRESOL, O-CRESOL AND P-CRESOL, P-AMINOPHENOL AND P-NITROPHENOL IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BREGA, A ;
PRANDINI, P ;
AMAGLIO, C ;
PAFUMI, E .
JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2) :311-316
[5]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[6]   Determination of total phenols in waters and wastewaters using flow injection with electrochemical detection; An alternative to the standard colorimetric procedure [J].
Christophersen, MJ ;
Cardwell, TJ .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :39-46
[7]  
Cordero-Rando MD, 1999, MIKROCHIM ACTA, V132, P7
[8]   Protein electrochemistry at carbon nanotube electrodes [J].
Davis, Jason J. ;
Coles, Richard J. ;
Hill, H.Allen O. .
1997, Elsevier Science S.A., Lausanne, Switzerland (440) :1-2
[9]  
FARRANT TJ, 1997, PRACTICAL STAT ANAL, P27
[10]   SPECTROPHOTOMETRIC DETERMINATION OF PHENOLIC-COMPOUNDS BY FLOW-INJECTION ANALYSIS [J].
FRENZEL, W ;
OLEKSYFRENZEL, J ;
MOLLER, J .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :253-259