Use of peptide retention time prediction for protein identification by off-line reversed-phase HPLC-MALDI MS/MS

被引:62
作者
Krokhin, Oleg V. [1 ]
Ying, Stephen
Cortens, John P.
Ghosh, Dhiman
Spicer, Victor
Ens, Werner
Standing, Kenneth G.
Beavis, Ronald C.
Wilkins, John A.
机构
[1] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T 2N2, Canada
[2] Univ Manitoba, Manitoba Ctr Proteom & Syst Biol, Winnipeg, MB R3E 3P4, Canada
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; FLIGHT MASS-SPECTROMETRY; TANDEM; MODEL;
D O I
10.1021/ac060251b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new algorithm, sequence-specific retention calculator, was developed to predict retention time of tryptic peptides during RP HPLC fractionation on C18, 300-angstrom pore size columns. Correlations of up to similar to 0.98 R-2 value were obtained for a test library of (similar to) 2000 peptides and similar to 0.95-0.97 for a variety of real samples. The algorithm was applied in conjunction with an exclusion protocol based on mass ( 15 ppm tolerance) and retention time (2-min tolerance for 0.66% acetonitrile/min gradient), MART criteria to significantly reduce the instrument time required for complete MS/MS analysis of a digest separated by RP HPLC. This was confirmed by reanalyzing the set of HPLC-MALDI MS/MS data with no loss in protein identifications, despite the number of virtually executed MS/MS analyses being decreased by 57%.
引用
收藏
页码:6265 / 6269
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 52 ASMS C MASS SPECT
[2]   THE ISOLATION OF PEPTIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PREDICTED ELUTION POSITIONS [J].
BROWNE, CA ;
BENNETT, HPJ ;
SOLOMON, S .
ANALYTICAL BIOCHEMISTRY, 1982, 124 (01) :201-208
[3]  
CHEN HS, 2001, ANAL CHEM, V7, P2323
[4]   TANDEM: matching proteins with tandem mass spectra [J].
Craig, R ;
Beavis, RC .
BIOINFORMATICS, 2004, 20 (09) :1466-1467
[5]   Lectin affinity as an approach to the proteomic analysis of membrane glycoproteins [J].
Ghosh, D ;
Krokhin, O ;
Antonovici, M ;
Ens, W ;
Standing, KG ;
Beavis, RC ;
Wilkins, JA .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (04) :841-850
[6]   PREDICTION OF PEPTIDE RETENTION TIMES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DETERMINATION OF RETENTION COEFFICIENTS OF AMINO-ACID-RESIDUES OF MODEL SYNTHETIC PEPTIDES [J].
GUO, DC ;
MANT, CT ;
TANEJA, AK ;
PARKER, JMR ;
HODGES, RS .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :499-517
[7]   Separation and identification of peptides in single neurons by microcolumn liquid chromatography -: Matrix-assisted laser desorption/ionization time-of flight mass spectrometry and postsource decay analysis [J].
Hsieh, S ;
Dreisewerd, K ;
van der Schors, RC ;
Jiménez, CR ;
Stahl-Zeng, JR ;
Hillenkamp, F ;
Jorgenson, JW ;
Geraerts, WPM ;
Li, KW .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1847-1852
[8]   Mass spectrometric characterization of proteins from the SARS virus - A preliminary report [J].
Krokhin, O ;
Li, Y ;
Andonov, A ;
Feldmann, H ;
Flick, R ;
Jones, S ;
Stroeher, U ;
Bastien, N ;
Dasuri, KVN ;
Cheng, KD ;
Simonsen, JN ;
Perreault, H ;
Wilkins, J ;
Ens, W ;
Plummer, F ;
Standing, KG .
MOLECULAR & CELLULAR PROTEOMICS, 2003, 2 (05) :346-356
[9]  
KROKHIN O, UNPUB ANAL CHEM
[10]   An improved model for prediction of retention times of tryptic peptides in ion pair reversed-phase HPLC - Its application to protein peptide mapping by off-line HPLC-MALDI MS [J].
Krokhin, OV ;
Craig, R ;
Spicer, V ;
Ens, W ;
Standing, KG ;
Beavis, RC ;
Wilkins, JA .
MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (09) :908-919