Efficacy of microbial sampling recommendations and practices in sub-Saharan Africa

被引:12
作者
Taylor, David D. J. [1 ]
Khush, Ranjiv [2 ]
Peletz, Rachel [3 ]
Kumpel, Emily [3 ,4 ]
机构
[1] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[2] Aquaya Inst, POB 5502, Santa Cruz, CA 95063 USA
[3] Riara Corp Suites, Aquaya Inst, Suite 203,Riara Rd,Kilimani Estate, Nairobi, Kenya
[4] Univ Massachusetts, Dept Civil & Environm Engn, Amherst, MA 01003 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Sampling programs; Microbial water quality; Guidelines for drinking water quality; Sub-saharan Africa; Statistical uncertainty; Water quality regulations; DRINKING-WATER QUALITY; FRAMEWORKS;
D O I
10.1016/j.watres.2018.01.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Current guidelines for testing drinking water quality recommend that the sampling rate, which is the number of samples tested for fecal indicator bacteria (FIB) per year, increases as the population served by the drinking water system increases. However, in low-resource settings, prevalence of contamination tends to be higher, potentially requiring higher sampling rates and different statistical methods not addressed by current sampling recommendations. We analyzed 27,930 tests for FIB collected from 351 piped water systems in eight countries in sub-Saharan Africa to assess current sampling rates, observed contamination prevalences, and the ability of monitoring agencies to complete two common objectives of sampling programs: determine regulatory compliance and detect a change over time. Although FIB were never detected in samples from 75% of piped water systems, only 14% were sampled often enough to conclude with 90% confidence that the true contamination prevalence met an example guideline (<= 5% chance of any sample positive for FIB). Similarly, after observing a ten percentage point increase in contaminated samples, 43% of PWS would still require more than a year before their monitoring agency could be confident that contamination had actually increased. We conclude that current sampling practices in these settings may provide insufficient information because they collect too few samples. We also conclude that current guidelines could be improved by specifying how to increase sampling after contamination has been detected. Our results suggest that future recommendations should explicitly consider the regulatory limit and desired confidence in results, and adapt when FIB is detected. (C) 2018 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 35 条
  • [1] [Anonymous], NS29 WAT RES CTR
  • [2] [Anonymous], AUSTR DRINK WAT GUID
  • [3] [Anonymous], 2008, Guidelines for drinking-water quality, V1
  • [4] [Anonymous], J AM WATER WORKS ASS
  • [5] [Anonymous], UG POP HOUS CENS POP
  • [6] [Anonymous], 2018, Guidelines for Drinking Water Quality
  • [7] [Anonymous], WASH POST 2015 PROP
  • [8] [Anonymous], 2015, PROGR SANITATION DRI
  • [9] [Anonymous], 2007, WORLD ENV WAT RES C, DOI DOI 10.1061/40927(243)481
  • [10] [Anonymous], 5 WAT SERV REG BOARD