Radiation exposure of staff during endovascular brachytherapy with Re-188 after PTA in the peripheral blood stream

被引:3
作者
Barth, Ilona [1 ]
Rimpler, Arndt [1 ]
Nikula, Tuomo [2 ]
Schilp, Michael [2 ]
Buck, Oliver [2 ]
Wengenmair, Hermann [3 ]
Leissner, Giesbert [3 ]
Kopp, Juergen [3 ]
Sciuk, Joachim [3 ]
机构
[1] Bundesamt Strahlenschutz, D-10318 Berlin, Germany
[2] Isotope Technol Munich AG Itm FlowMed GmbH, D-85748 Garching, Germany
[3] Klinikum Augsburg, D-86156 Augsburg, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2009年 / 19卷 / 03期
关键词
Radiation protection; staff; skin dose; endovascular brachytherapy; Re-188;
D O I
10.1016/j.zemedi.2009.01.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Endovascular brachytherapy using a balloon catheter filled with Re-188 solution is a promising method for the prophylaxis of restenosis in peripheral blood circulation after percutaneous transluminal angioplasty (PTA) treatments. Thereby about 20 GBq Re-188 with a specific activity of about 5 GBq/ml are used. The high ionisation density of the beta radiation with high energy leads to selective irradiation of the blood vessel wall near the catheter, whereas the surrounding tissue remains almost unaffected However the hospital staff has to carry out some work steps within close range to the high activity during preparation and therapy, causing a high risk of skin exposure, in particular at the hands. Estimations and measurements of the maximal local skin close were made with thin-la layered thermoluminescence dosimeters. It was assessed that the annual dose limit for skin of 500 mSv may be exceeded considerably when using conventional procedures and considering the expected number of 75 treatments per annum. By using the newly developed rhenium-188 application device "Flow Medical Application System" the exposure risk for the staff could be reduced drastically. The maximum skin dose of 76 mSv for the radiologist and of 50 mSv for the physicist was decreased to 2 mSv per treatment for both of them. Consequently, from the radiation protection point of view, the itm Rhenium-PTA (R) is a safe method Any exceeding of the (lose limit can be prevented.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 11 条
  • [1] Andreeff M, 2005, NUKLEARMED-NUCL MED, V44, P94
  • [2] BARTH I, 2006, MTA DIALOG, V7, P14
  • [3] BARTH I, 2004, 11 INT C INT RAD PRO, V517
  • [4] Radiation protection in radionuclide therapies with 90Y-conjugates:: risks and safety
    Cremonesi, Marta
    Ferrari, Mahila
    Paganelli, Giovanni
    Rossi, Annalisa
    Chinol, Marco
    Bartolomei, Mirco
    Prisco, Gennaro
    Tosi, Giampiero
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (11) : 1321 - 1327
  • [5] Pharmacokinetics of 99Tcm-pertechnetate and 188Re-perrhenate after oral administration of perchlorate:: Option for subsequent care after the use of liquid 188Re in a balloon catheter
    Kotzerke, J
    Fenchel, S
    Guhlmann, A
    Stabin, M
    Rentschler, M
    Knapp, FF
    Reske, SN
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (08) : 795 - 801
  • [6] Dosimetry in leakage of 188Re-DTPA during intracoronary balloon brachytherapy
    Paeng, JC
    Lee, DS
    Kang, WJ
    Yang, HM
    Chung, JK
    Jeong, JM
    Chae, IH
    Lee, MM
    Lee, MC
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (09) : 1263 - 1265
  • [7] Beta radiation exposure of staff during and after therapies with 90Y-labelled substances
    Rimpler, A.
    Barth, I.
    Baum, R. B.
    Senftleben, S.
    Geworski, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 73 - 79
  • [8] RIMPLER A, 2005, NUKLEARMEDIZINER, V28, P1
  • [9] Monte Carlo modeling of radiation dose distributions in intravascular radiation therapy
    Stabin, MG
    Konijnenberg, M
    Knapp, FF
    Spencer, RH
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 1086 - 1092
  • [10] WACHSMANN R, 2002, LANCET, V359, P551