The impact of erythrocyte lysing procedures on the recovery of hematopoietic progenitor cells in flow cytometric analysis

被引:16
作者
Greve, Burkhard
Beller, Constanze
Cassens, Uwe
Sibrowski, Walter
Goehde, Wolfgang
机构
[1] Univ Hosp Munster, Dept Radiobiol, D-48149 Munster, Germany
[2] Univ Hosp Munster, Dept Transfus Med, D-48149 Munster, Germany
[3] St Franziskus, Dept Cardiol, D-48149 Munster, Germany
关键词
hematopoietic cell transplants; leukapheresis; flow cytometry; erythrocyte lysing;
D O I
10.1634/stemcells.2005-0269
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Since preanalytic lysing of erythrocytes remains critical in flow cytometry, we investigated the influence of four lysing procedures on the quantification of leukocyte and CD34(+) cells in hematopoietic cell transplants (HCTs). Samples were derived from stem cell-enriched mobilized whole blood collected by apheresis (unselected) and immunologically purified stem cell products (selected) and were measured using the dual-platform (2-PF) method with two flow cytometric systems. Additionally, cells were measured by a volume-based technique (single platform [1-PF]). Results were identical in the 2-PF mode (unselected HCTs, r = 0.998; selected HCTs, r = 0.999). In comparison with the 2-PF results, the single-platform (1-PF) measurements revealed a mean decrease of 59.5% for CD34(+) cells (50.8% for CD45(+) cells) in unselected HCTs and a mean decrease of 52% for CD34(+) cells (49.8% for CD45(+) cells) in selected HCTs. In order to check the accuracy of cell quantification using the 1-PF method, leukocyte reference values from hematology counter results were compared with flow cytometric (1-PF)counted nucleated cells. That analysis revealed good congruency, with r = 0.998 for unselected HCTs and r = 0.999 for selected HCTs. In conclusion, all lysing procedures that we used induced substantial loss of leukocytes and CD34(+) cells. As demonstrated by the high accuracy of the 1-PF technique, all erythrocyte lysing procedures caused significant cell loss, which led to inconsistent counting of CD34(+) cells in nonvolumetric flow cytometric (2-PF) protocols.
引用
收藏
页码:793 / 799
页数:7
相关论文
共 34 条
[1]   A multicolor, no-lyse, no-wash assay for the absolute counting of CD34+ cells by flow cytometry [J].
Alvarez-Larran, A ;
Jover, L ;
Marin, P ;
Petriz, J .
CYTOMETRY, 2002, 50 (05) :249-253
[2]   Technical aspects and clinical impact of hematopoietic progenitor subset quantification [J].
Baech, J ;
Johnsen, HE .
STEM CELLS, 2000, 18 (02) :76-86
[3]  
Barnett D, 1999, BRIT J HAEMATOL, V106, P1059
[4]   Guideline for the flow cytometric enumeration of CD34+ haematopoietic stem cells [J].
Barnett, D ;
Janossy, G ;
Lubenko, A ;
Matutes, E ;
Newland, A ;
Reilly, JT .
CLINICAL AND LABORATORY HAEMATOLOGY, 1999, 21 (05) :301-308
[5]  
Brando B, 2000, CYTOMETRY, V42, P327, DOI 10.1002/1097-0320(20001215)42:6<327::AID-CYTO1000>3.0.CO
[6]  
2-F
[7]   Comparison of volumetric capillary cytometry with standard flow cytometry for routine enumeration of CD34+cells [J].
Cabezudo, E ;
Querol, S ;
Cancelas, JA ;
García, J .
TRANSFUSION, 1999, 39 (08) :864-872
[8]  
Cassens U, 2004, ANTIVIR THER, V9, P395
[9]   A novel true volumetric method for the determination of residual leucocytes in blood components [J].
Cassens, U ;
Greve, B ;
Tapernon, K ;
Nave, B ;
Severin, E ;
Sibrowski, W ;
Göhde, W .
VOX SANGUINIS, 2002, 82 (04) :198-206
[10]  
Cassens U, 1998, TRANSFUSION MED, V8, P111