Experimental enhancement of a CO2 transcritical refrigerating plant including thermoelectric subcooling

被引:35
作者
Sanchez, D. [1 ]
Aranguren, P. [2 ]
Casi, A. [2 ]
Llopis, R. [1 ]
Cabello, R. [1 ]
Astrain, D. [2 ]
机构
[1] Jaume I Univ, Dept Mech Engn & Construct, Campus Riu Sec S-N, E-12071 Castellon de La Plana, Spain
[2] Univ Publ Navarra, Dept Engn, Campus Arrosadia S-N, E-31006 Pamplona, Spain
关键词
CO2; R744; Subcooling; Thermoelectric subcooling; Transcritical cycle; IHX; INTERNAL HEAT-EXCHANGER; PERFORMANCE OPTIMIZATION; ENERGETIC EVALUATION; WORKING; CYCLE; SYSTEM; IMPROVEMENTS; DESIGN; COOLER; PIPES;
D O I
10.1016/j.ijrefrig.2020.08.031
中图分类号
O414.1 [热力学];
学科分类号
摘要
CO2 is an excellent natural refrigerant that can be used in almost any commercial cooling application thanks to its useful range of evaporative temperatures and excellent environmental properties. However, due to its low critical temperature, CO2 has an important issue related to the low performance of the simplest transcritical refrigeration cycle. To overcome it, the subcooling technique is a well-known method to improve the energy performance of any refrigeration cycle especially the CO2 transcritical one. The IHX is a widely used example of this method that is implemented in almost all standalone systems that use CO2 as a refrigerant. As an alternative of this element, in this work, a thermoelectric subcooling system is presented and tested in a CO2 transcritical refrigerating plant. The experimental tests have been performed at two ambient temperatures: 25 and 30 degrees C, maintaining a constant evaporating level at-10 degrees C and varying the voltage supply to thermoelectric modules and the heat rejection pressure. The results from these experimental tests revealed that the COP and the cooling capacity of the refrigerating plant can be enhanced up to 9.9% and 16.0%, respectively, operating at the optimum operating conditions. Moreover, the experimental tests corroborate the existence of an optimum voltage which maximizes the COP, and the almost linear capacity regulation easily adjustable by varying the voltage supply. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 1995, HDB THERMOELECTRICS, DOI DOI 10.1016/S0960-1481(98)00512-6.
[2]  
Araiz M., 2018, IMPORTANCE ASSEMBLY, V7, DOI [10.5772/intechopen.75697., DOI 10.5772/INTECHOPEN.75697]
[3]   Heat pipes thermal performance for a reversible thermoelectric cooler-heat pump for a nZEB [J].
Aranguren, P. ;
DiazDeGarayo, S. ;
Martinez, A. ;
Araiz, M. ;
Astrain, D. .
ENERGY AND BUILDINGS, 2019, 187 :163-172
[4]   Auxiliary consumption: A necessary energy that affects thermoelectric generation [J].
Aranguren, P. ;
Araiz, M. ;
Astrain, D. .
APPLIED THERMAL ENGINEERING, 2018, 141 :990-999
[5]   Improvements in the cooling capacity and the COP of a transcritical CO2 refrigeration plant operating with a thermoelectric subcooling system [J].
Astrain, D. ;
Merino, A. ;
Catalan, L. ;
Aranguren, P. ;
Araiz, M. ;
Sanchez, D. ;
Cabello, R. ;
Llopis, R. .
APPLIED THERMAL ENGINEERING, 2019, 155 :110-122
[6]   Study of the influence of heat exchangers' thermal resistances on a thermoelectric generation system [J].
Astrain, D. ;
Vian, J. G. ;
Martinez, A. ;
Rodriguez, A. .
ENERGY, 2010, 35 (02) :602-610
[7]   Experimental evaluation of the energy efficiency of a CO2 refrigerating plant working in transcritical conditions [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Torrella, E. .
APPLIED THERMAL ENGINEERING, 2008, 28 (13) :1596-1604
[8]   Optimization of thermoelectric cooling system for application in CPU cooler [J].
Cai, Yang ;
Liu, Di ;
Yang, Jing-Jing ;
Wang, Yu ;
Zhao, Fu-Yun .
8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 :1644-1650
[9]   Improvements in CO2 Booster Architectures with Different Economizer Arrangements [J].
Catalan-Gil, J. ;
Nebot-Andres, L. ;
Sanchez, D. ;
Llopis, R. ;
Cabello, R. ;
Calleja-Anta, D. .
ENERGIES, 2020, 13 (05)
[10]   Experimental evaluation of the desuperheater influence in a CO2 booster refrigeration facility [J].
Catalan-Gil, Jesus ;
Sanchez, Daniel ;
Cabello, Ramon ;
Llopis, Rodrigo ;
Nebot-Andres, Laura ;
Calleja-Anta, Daniel .
APPLIED THERMAL ENGINEERING, 2020, 168