Cone-Beam CT-Guided Lung Biopsies: Results in 94 Patients

被引:8
作者
Gulias-Soidan, Daniel [1 ]
Crus-Sanchez, Nilfa Milena [1 ]
Fraga-Manteiga, Daniel [1 ]
Cao-Gonzalez, Juan Ignacio [1 ]
Balboa-Barreiro, Vanesa [2 ]
Gonzalez-Martin, Cristina [3 ]
机构
[1] Complejo Hosp Univ A Coruna CHUAC, Dept Intervent Radiol, As Xubias 84, La Coruna 15006, Spain
[2] Univ A Coruna UDC, Complejo Hosp Univ A Coruna CHUAC, Biomed Res Inst A Coruna INIBIC, Clin Epidemiol & Biostat Unit,SERGAS, As Xubias 84, La Coruna 15006, Spain
[3] Univ Coruna UDC, Complejo Hosp Univ A Coruna CHUAC, Biomed Res Inst A Coruna INIBIC,SERGAS, Rheumatol & Publ Hlth Res Grp,Nursing Res & Hlth, As Xubias 84, La Coruna 15006, Spain
关键词
lung; transthoracic biopsy; radiation; TRANSTHORACIC NEEDLE-BIOPSY; SYSTEM DIAGNOSTIC-ACCURACY; ASPIRATION BIOPSY; RISK-FACTORS; ARTIFICIAL-INTELLIGENCE; PNEUMOTHORAX; NODULES; COMPLICATION; EXPERIENCE; FUTURE;
D O I
10.3390/diagnostics10121068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to evaluate the diagnostic capacity of Cone-Beam computed tomography (CT)-guided transthoracic percutaneous biopsies on lung lesions in our setting and to detect risk factors for possible complications. Methods: Retrospective study of 98 biopsies in 94 patients, performed between May 2017 and January 2020. To obtain them, a 17G coaxial puncture system and a Siemens Artis Zee Floor vc21 archwire were used. Descriptive data of the patients, their position at the time of puncture, location and size of the lesions, number of cylinders extracted, and complications were recorded. Additionally, the fluoroscopy time used in each case, the doses/area and the estimated total doses received by the patients were recorded. Results: Technical success was 96.8%. A total of 87 (92.5%) malignant lesions and 3 (3.1%) benign lesions were diagnosed. The sensitivity was 91.5% and the specificity was 100%. We registered three technical failures and three false negatives initially. Complications included 38 (38.8%) pneumothorax and 2 (2%) hemoptysis cases. Fluoroscopy time used in each case was 4.99 min and the product of the dose area is 11,722.4 microGy/m(2). Conclusion: The transthoracic biopsy performed with Cone-Beam CT is accurate and safe in expert hands for the diagnosis of lung lesions. Complications are rare and the radiation dose used was not excessive.
引用
收藏
页数:13
相关论文
共 31 条
  • [1] Prospective Randomized Trial for Image Guided Biopsy Using Cone-Beam CT Navigation Compared with Conventional CT
    Abi-Jaoudeh, Nadine
    Fisher, Teresa
    Jacobus, John
    Skopec, Marlene
    Radaelli, Alessandro
    Van der Born, Imramsjah Martijn
    Wesley, Robert
    Wood, Bradford J.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (09) : 1342 - 1349
  • [2] Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
    Braak, Sicco J.
    Herder, Gerarda J. M.
    van Heesewijk, Johannes P. M.
    van Strijen, Marco J. L.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (06) : 1414 - 1421
  • [3] Does biopsy needle traversing through central portion of lesion increase the risk of hemoptysis during percutaneous transthoracic needle biopsy?
    Chen, Chia-Hung
    Huang, Wei-Ming
    Liang, Shih-Hsuan
    Jhou, Zong-Yi
    Chen, Chien-Wen
    Chien, Yu-Chan
    Lin, Hui-Chen
    Wang, Chih-Hsin
    Huang, Chun-Chao
    Liao, Wei-Ni
    Huang, Chung-Yao
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (03) : 231 - 237
  • [4] C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Needle Biopsy of Small (≤ 20 mm) Lung Nodules: Diagnostic Accuracy and Complications in 161 Patients
    Choi, Jin Woo
    Park, Chang Min
    Goo, Jin Mo
    Park, Yang-Kyun
    Sung, Wonmo
    Lee, Hyun-Ju
    Lee, Sang Min
    Ko, Ji Young
    Shim, Mi-Suk
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : W322 - W330
  • [5] Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety
    Choi, M. J.
    Kim, Y.
    Hong, Y. S.
    Shim, S. S.
    Lim, S. M.
    Lee, J. K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014) : E182 - E187
  • [6] Percutaneous transthoracic needle biopsy of small (aparts per thousandcurrency sign1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance
    Choo, Ji Yung
    Park, Chang Min
    Lee, Nyoung Keun
    Lee, Sang Min
    Lee, Hyun-Ju
    Goo, Jin Mo
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (03) : 712 - 719
  • [7] Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax
    Cox, JE
    Chiles, C
    McManus, CM
    Aquino, SL
    Choplin, RH
    [J]. RADIOLOGY, 1999, 212 (01) : 165 - 168
  • [8] Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose
    Fior, Davide
    Vacirca, Francesco
    Leni, Davide
    Pagni, Fabio
    Ippolito, Davide
    Riva, Luca
    Sironi, Sandro
    Corso, Rocco
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (05) : 712 - 719
  • [9] CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate
    Geraghty, PR
    Kee, ST
    McFarlane, G
    Razavi, MK
    Sze, DY
    Dake, MD
    [J]. RADIOLOGY, 2003, 229 (02) : 475 - 481
  • [10] Flat-Panel Volume CT: Fundamental Principles, Technology, and Applications
    Gupta, Rajiv
    Cheung, Arnold C.
    Bartling, Soenke H.
    Lisauskas, Jennifer
    Grasruck, Michael
    Leidecker, Christianne
    Schmidt, Bernhard
    Flohr, Thomas
    Brady, Thomas J.
    [J]. RADIOGRAPHICS, 2008, 28 (07) : 2009 - 2022