Influence on imaging qualities of photoacoustic tomography caused by mismatch of ultrasonic velocities

被引:1
作者
Yang, Sihua [1 ]
Gu, Huaimin [1 ]
机构
[1] South China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
来源
FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2 | 2006年 / 6047卷
基金
中国国家自然科学基金;
关键词
acoustic path difference (APD); photoacoustic tomography; photoacoustic signals;
D O I
10.1117/12.710945
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, Influences of the acoustic path difference on photoacoustic(PA) images caused by mismatch of ultrasonic velocities were studied. We first proposed using the concentration-adjustable glycerite as an ultrasonic transmitting medium. By switching a appropriate concentration of the glycerite.. it can make the velocities of the PA signals keep constant between transmitting medium and biological tissues, and avoid the acoustic path difference (APD) in image reconstruction. The experiments demonstrate that the acoustic path difference influences the imaging qualities badly: especially. the spatial resolution of PA image is extremely reduced. After matching ultrasonic velocity by glycerite the contrast of the reconstructed image is improved greatly and the background artifacts are reduced obviously The spatial resolution of the reconstructed image is improved from 0.5mm to 0.15mm. It has great practical significance for applying photoacoustic tomography to noninvasive clinic diagnosis of cancer.
引用
收藏
页数:6
相关论文
共 12 条
[1]   Image reconstruction for photoacoustic scanning of tissue structures [J].
Hoelen, CGA ;
de Mul, FFM .
APPLIED OPTICS, 2000, 39 (31) :5872-5883
[2]   In vivo photoacoustic imaging of blood vessels using an extreme-narrow aperture sensor [J].
Kolkman, RGM ;
Hondebrink, E ;
Steenbergen, W ;
de Mul, FFM .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (02) :343-346
[3]   AVERAGE VELOCITY OF ULTRASOUND IN HUMAN FEMALE BREAST [J].
KOSSOFF, G ;
FRY, EK ;
JELLINS, J .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (06) :1730-1736
[4]   Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response [J].
Köstli, KP ;
Beard, PC .
APPLIED OPTICS, 2003, 42 (10) :1899-1908
[5]  
Tan Yi, 2005, Acta Optica Sinica, V25, P40
[6]   Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain [J].
Wang, XD ;
Pang, YJ ;
Ku, G ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
NATURE BIOTECHNOLOGY, 2003, 21 (07) :803-806
[7]   Photoacoustic imaging with deconvolution algorithm [J].
Wang, Y ;
Xing, D ;
Zeng, YG ;
Chen, Q .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) :3117-3124
[8]   Time-domain reconstruction-algorithms and numerical simulations for thermoacoustic tomography in various geometries [J].
Xu, MH ;
Xu, Y ;
Wang, LHV .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (09) :1086-1099
[9]  
Yin Bangzheng, 2005, Acta Optica Sinica, V25, P331
[10]  
Yin CY, 2004, ACTA PALAEONTOL POL, V49, P1