Cyclic loading of Achilles tendon repairs: A comparison of polyester and polyblend suture

被引:32
作者
Benthien, Ross A.
Aronow, Michael S.
Doran-Diaz, Vilmaris
Sullivan, Raymond J.
Naujoks, Ryan
Adams, Douglas J.
机构
[1] Orthoped Associates Hartford, Hartford, CT 06106 USA
[2] Univ Connecticut, Ctr Hlth, Dept Orthopaed Surg, Farmington, CT USA
[3] Univ Connecticut, Sch Med, Farmington, CT USA
关键词
Achilles; cyclic loading; suture repair;
D O I
10.1177/107110070602700706
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Early functional rehabilitation is widely used after open suture repair of the Achilles tendon. To our knowledge, no previous studies have assessed gap formation from cyclic loading and subsequent failure loads of simulated Achilles tendon repairs. A synthetic (polyblend) suture has been introduced for tendon repairs with reportedly greater strength than polyester suture. This stronger, stiffer suture material may provide stronger repairs with less elongation of the tendon repair. Methods: Simulated Achilles tendon ruptures in bovine Achilles tendon were repaired with a four-strand Krackow suture technique using No. 2 polyester suture. Specimens were loaded for 3000 cycles at maximal loads of 50, 75, 100, or 125 N, and gap formation at the repair site was continuously measured. After cyclic loading, each specimen was loaded to failure. Identical repairs were performed with number 2 polyblend suture and cyclically loaded to 75 N for 3000 cycles. All specimens were loaded to failure. Results: Cyclically loading polyester suture repairs to 50, 75, 100, or 125 N for 3000 cycles resulted in mean gapping at the repair site of 3.0 +/- 0.8,4.9 +/- 1.0,7.2 +/- 0.9, and 7.9 +/- 0.8 rum, respectively. Cyclically loading the polyblend suture repairs for 3000 cycles at 75 N, resulted in 3.3 +/- 0.3 mm of gap formation at the repair site, significantly less than polyester suture repairs (p < 0.001). The mean load to failure for polyester suture repair was 222 +/- 19 N and for polyblend suture repair was 582 +/- 49 N, a statistically significant difference (p < 0.001). Gap formation at 100, 1000, and 2000 cycles, as a percentage of total gap formation at 3000 cycles, was 64.3%, 87.5%, and 95.4% for polyester suture and 45.8%, 78.5%, and 90.1% for polyblend repairs. All specimens in all groups failed at the knots during load-to-failure testing. Conclusions: Cyclic loading of simulated Achilles tendon repairs using a Krackow, four-core polyester suture technique showed progressive gap formation with increasing load. All repairs failed at the knot, and suture pull-out from tendon was not observed. Polyblend suture repair, when compared to identical repairs with braided polyester suture, resulted in a 260% higher load to failure and 33% less gap formation at the repair site after 3000 cycles. Clinical Relevance: The use of polyblend suture in a four-stranded Krackow configuration provides stronger repairs with less gap formation, which may provide increased security during early functional rehabilitation.
引用
收藏
页码:512 / 518
页数:7
相关论文
共 31 条
[1]   Early active motion and weightbearing after cross-stitch Achilles tendon repair [J].
Aoki, M ;
Ogiwara, N ;
Ohta, T ;
Nabeta, Y .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (06) :794-800
[2]  
ARTHREX, 2001, COLL SUMM STRENGTH B
[3]   Limited open repair of Achilles tendon ruptures - A technique with a new instrument and findings of a prospective multicenter study [J].
Assal, M ;
Jung, M ;
Stern, R ;
Rippstein, P ;
Delmi, M ;
Hoffmeyer, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :161-170
[4]  
Bhandari M, 2002, CLIN ORTHOP RELAT R, P190
[5]   FUNCTIONAL POSTOPERATIVE TREATMENT OF ACHILLES-TENDON REPAIR [J].
CARTER, TR ;
FOWLER, PJ ;
BLOKKER, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (04) :459-462
[6]   OPERATIVE VERSUS NONOPERATIVE TREATMENT OF ACHILLES-TENDON RUPTURE - A PROSPECTIVE RANDOMIZED STUDY AND REVIEW OF THE LITERATURE [J].
CETTI, R ;
CHRISTENSEN, SE ;
EJSTED, R ;
JENSEN, NM ;
JORGENSEN, U .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :791-799
[7]   Achilles tendon rupture repair: Biomechanical comparison of the triple bundle technique versus the Krakow locking loop technique [J].
Jaakkola, JI ;
Hutton, WC ;
Beskin, JL ;
Lee, GP .
FOOT & ANKLE INTERNATIONAL, 2000, 21 (01) :14-17
[8]   Functional treatment versus early immobilization in tension of the musculotendinous unit after Achilles rupture repair:: A prospective, randomized, clinical study [J].
Kangas, J ;
Pajala, A ;
Siira, P ;
Hämäläinen, M ;
Leppilahti, J .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (06) :1171-1181
[9]   A NEW STITCH FOR LIGAMENT-TENDON FIXATION - BRIEF NOTE [J].
KRACKOW, KA ;
THOMAS, SC ;
JONES, LC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :764-766
[10]   Strength analysis and comparison of the Teno Fix® Tendon Repair System with the two-strand modified Kessler repair in the Achilles tendon [J].
Lewis, N ;
Quitkin, HM .
FOOT & ANKLE INTERNATIONAL, 2003, 24 (11) :857-860