Malpositioning of the Lag Screws by 1- or 2-screw Nailing Systems for Pertrochanteric Femoral Fractures: A Biomechanical Comparison of Gamma 3 and Intertan

被引:7
|
作者
Nuechtern, Jakob V. [1 ]
Ruecker, Andreas H. [1 ]
Sellenschloh, Kay [2 ]
Rupprecht, Martin [1 ]
Pueschel, Klaus [3 ]
Rueger, Johannes M. [1 ]
Morlock, Michael M. [2 ]
Lehmann, Wolfgang [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[2] Hamburg Univ Technol, Biomech Sect, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
关键词
osteoporosis; intramedullary nail; intertrochanteric fracture; biomechanics; lag screw; INTERNAL-FIXATION; NECK FRACTURES; HIP SCREW; FAILURE; OSTEOPOROSIS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The aim of this investigation was to perform a biomechanical comparison between 1- and 2-screw systems used for the treatment of intertrochanteric fractures for centralized and decentralized placement of femoral neck screws of failure loads, stiffness, survival rates, tip apex distance (TAD), and failure mode. Methods: As fracture model, an AO 31A2.3 fracture was used. Twelve pairs of human cadaver femora were tested. Femoral neck screws were implanted in the femoral head in center/center, posterior/central, and anterior/superior position in axial/frontal plane. A single-screw system (Gamma 3 Locking Nail; Stryker GmbH & Co. KG) and a 2-screw system (Trigen-Intertan; Smith & Nephew GmbH) were used. To simulate the load in situ, a cyclic load was carried for 10,000 cycles in a material testing machine. If no cyclic failure occurred, femora were loaded until the failure. The systems were compared according to the stiffness, survivability through 10 k cycles, TAD, and load to failure. Results: None of the tested bones failed at center/center location in the decentralized positions 3 Gamma Nail and 2 Intertan specimens failed during cyclic testing. The 2-screw system resisted higher forces in all positions (Gamma: 5370N +/- 1924, Intertan: 7650N +/- 2043; P = 0.014). Conclusions: Based on these data, it is clear that both the nail systems showed a higher biomechanical stability with a lower TAD. The 2 specimens that failed with the Intertan in the cyclic tests had a TAD >= 49 mm. The cutout failures that we detected during cyclic testing in the Gamma system had a TAD >= 30 mm. Thus, it is clear that the TAD affects failure independent of the implant used. With a less than ideal lag screw placement, however, the Intertan system with 2 integrated screws was able to withstand higher loads in this study.
引用
收藏
页码:276 / 282
页数:7
相关论文
共 5 条
  • [1] Biomechanical Comparison of a Novel 3-Screw Fixation vs Conventional 2-Screw Fixation of Calcaneal Tuberosity Avulsion Fractures
    Hong, Choon Chiet
    Tan, Jun-Hao
    Ramruttun, Amit Kumarsing
    Pearce, Christopher Jon
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (12) : 1562 - 1568
  • [2] Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation
    Riedl, Markus
    Glisson, Richard R.
    Matsumoto, Takumi
    Hofstaetter, Stefan G.
    Easley, Mark E.
    CLINICAL BIOMECHANICS, 2017, 45 : 32 - 37
  • [3] Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail
    Zhu, Yi
    Meili, Severin
    Zhang, Changqing
    Luo, Congfeng
    Zeng, Bing-fang
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2012, 20
  • [4] Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail
    Yi Zhu
    Severin Meili
    Changqing Zhang
    Congfeng Luo
    Bing-fang Zeng
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 20
  • [5] Migration of the Lag Screw after Intramedullary Treatment of AO/OTA 31.A2.1-3 Pertrochanteric Fractures Does Not Result in Higher Incidence of Cut-Outs, Regardless of Which Implant Was Used: A Comparison of Gamma Nail with and without U-Blade (RC) Lag Screw and Proximal Femur Nail Antirotation (PFNA)
    Lang, Nikolaus Wilhelm
    Breuer, Robert
    Beiglboeck, Hannes
    Munteanu, Alexandru
    Hajdu, Stefan
    Windhager, Reinhard
    Widhalm, Harald Kurt
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (05)