Moderate sea states do not influence the application of an AED in rigid inflatable boats

被引:17
作者
de Vries, Wiebe
Bierens, Joost J. L. M.
Maas, Martijn W. M.
机构
[1] Doczero, Dept Educ & Dev, NL-5406 NK Uden, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Anaesthesiol, NL-1007 MB Amsterdam, Netherlands
[3] Orange Cross, Dept Res & Dev, NL-2500 BL The Hague, Netherlands
关键词
automated external defibrillator; defibrillation; drowning; transport;
D O I
10.1016/j.resuscitation.2006.01.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: This study was to determine if the AED can be operated correctly on board rigid inflatable rescue boats (RIBs), and if downloading of data later for quality control is possible. Methods: Six AEDs were tested for their reliability, robustness and stability. Data were collected on three different types of RIBs, in a harbour and at sea. Each AED was connected to a volunteer and a manikin simulating VF. Data from the AED were continuously collected. Results: At one of the RIBs each AED became wet; no AED had a technical problem. When connected to the volunteer, the ECGs delivered by the AEDs showed a regular sinus rhythm. When connected to a manikin in VF, each AED was able to recognise VF and to provide a shock. There were differences in the time between first analysis and the shock. The voice prompt of the Zoll AED Plus was 'understandable', while the other AEDs were 'difficult to understand'. We had a problem with the infrared connection, which means that evaluation and quality control afterwards may be difficult. Conclusion: The use of AEDs on RIBs during patient transport over calm water is possible and effective. The AED should have a screen and better features to download data. However, AEDs are only worthwhile when they fit well in the Chain of Survival (fast arrival, immediately availability of an AED, trained provider and advanced life support). (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 15 条
[1]  
*CARD, 2004, REC NOT AED ACC AUT
[2]   IMPROVING SURVIVAL FROM SUDDEN CARDIAC-ARREST - THE CHAIN OF SURVIVAL CONCEPT - A STATEMENT FOR HEALTH-PROFESSIONALS FROM THE ADVANCED CARDIAC LIFE-SUPPORT SUBCOMMITTEE AND THE EMERGENCY CARDIAC CARE COMMITTEE, AMERICAN-HEART-ASSOCIATION [J].
CUMMINS, RO ;
ORNATO, JP ;
THIES, WH ;
PEPE, PE ;
BILLI, JE ;
SEIDEL, J ;
JAFFE, AS ;
FLINT, LS ;
GOLDSTEIN, S ;
ABRAMSON, NS ;
BROWN, C ;
CHANDRA, NC ;
GONZALEZ, ER ;
NEWELL, L ;
STULTS, KR ;
MEMBRINO, GE .
CIRCULATION, 1991, 83 (05) :1832-1847
[3]  
DOKTER P, 1992, REDDINGWEZEN, V81, P220
[4]   Comparison of ease of use of three automated external defibrillators by untrained lay people [J].
Eames, P ;
Larsen, PD ;
Galletly, DC .
RESUSCITATION, 2003, 58 (01) :25-30
[5]   Differing operational outcomes with six commercially available automated external defibrillators [J].
Fleischhackl, R ;
Losert, H ;
Haugk, M ;
Eisenburger, P ;
Sterz, F ;
Laggner, AN ;
Herkner, H .
RESUSCITATION, 2004, 62 (02) :167-174
[6]  
Kyle J M, 1999, W V Med J, V95, P258
[7]  
Lyster Tom, 2003, Prehosp Emerg Care, V7, P307, DOI 10.1080/10903120390936473
[8]   The Public Access Defibrillation (PAD) Trial - Study design and rationale [J].
Ornato, JP ;
McBurnie, MA ;
Nichol, G ;
Salive, M ;
Weisfeldt, M ;
Riegel, B ;
Christenson, J ;
Terndrup, T ;
Daya, M ;
Mann, NC ;
Shaum, B ;
Brown, K ;
Jacobsen, K ;
Zalenski, R ;
Compton, S ;
Dunne, R ;
Swor, R ;
Welch, R ;
Mango, L ;
Bilicki, K ;
Daya, M ;
Gunnels, MD ;
Hedges, JR ;
Jui, J ;
Schmidt, T ;
Wittwer, L ;
Brooks, H ;
Burke, C ;
Griffiths, D ;
Becker, LB ;
Barry, A ;
Demertsidies, E ;
Sayre, MR ;
Christenson, J ;
Pennington, S ;
Holmes, A ;
Payne, H ;
Webb, R ;
Douglas, N ;
Lawson, P ;
Henry, MC ;
Johnson, S ;
Stapleton, ER ;
VanZile, J ;
Ottaway, M ;
O'Connor, RE ;
McGraw, P ;
Bollinger, M ;
Megargel, RE ;
Ehrlich, S .
RESUSCITATION, 2003, 56 (02) :135-147
[9]   Use of automated external defibrillators by a US airline. [J].
Page, RL ;
Joglar, JA ;
Kowal, RC ;
Zagrodzky, JD ;
Nelson, LL ;
Ramaswamy, K ;
Barbera, SJ ;
Hamdan, MH ;
McKenas, DK .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (17) :1210-1216
[10]   In-water resuscitation: a pilot evaluation [J].
Perkins, GD .
RESUSCITATION, 2005, 65 (03) :321-324