Tricuspid Regurgitation Related to Cardiac Implantable Electronic Devices: An Integrative Review

被引:39
作者
Gelves-Meza, Julian [1 ]
Lang, Roberto M. [2 ]
Valderrama-Achury, Maria Daniela [3 ]
Luis Zamorano, Jose [4 ]
Vargas-Acevedo, Catalina [5 ]
Manuel Medina, Hector [6 ]
Salazar, Gabriel [3 ]
机构
[1] Univ Rosario, Escuela Med & Ciencias Salud, Echocardiog Lab, Fdn Cardioinfantil,Inst Cardiol, Bogota, Colombia
[2] Univ Chicago Med, Cardiac Imaging Ctr, Dept Med, Sect Cardiol, Chicago, IL USA
[3] Inst Cardiol, Echocardiog Lab, Fdn Cardioinfantil, Calle 163a,13B-60,Bldg 1,10th Floor, Bogota, Colombia
[4] Hosp Univ Ramon y Cajal, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, Inst Salud Carlos III, Sect Cardiol, Madrid, Spain
[5] Inst Cardiol, Fdn Cardioinfantil, Inst Congenital Heart Dis, Bogota, Colombia
[6] Inst Cardiol, Fdn Cardioinfantil, Cardiac Imaging, Bogota, Colombia
关键词
Tricuspid regurgitation; Artificial cardiac pacing; 3D echocardiography; Device lead; Right ventricular dysfunction; NATIVE VALVULAR REGURGITATION; TRANSVENOUS LEAD EXTRACTION; TERM-FOLLOW-UP; CARDIOVERTER-DEFIBRILLATOR; PERMANENT PACEMAKER; VALVE REGURGITATION; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; CLINICAL UTILITY;
D O I
10.1016/j.echo.2022.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of cardiac implantable electronic devices, including permanent pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy, has dramatically increased in recent years. The interaction between the device lead and tricuspid valve leaflets is a potential cause of tricuspid regurgitation that in turn has an impact on morbidity and mortality. Echocardiography is necessary to grade tricuspid regurgitation severity. The use of three-dimensional imaging helps determine whether the device lead is interfering with normal leaflet coaptation. Early identification of lead-related tricuspid regurgitation is critical to select the optimal treatment, which may include lead extraction or even tricuspid valve repair or replacement in severe cases. The aims of this review are to provide a thorough assessment of the evidence about lead-associated tricuspid regurgitation and the benefits of using three-dimensional echocardiography with some technical considerations and to propose a treatment algorithm.
引用
收藏
页码:1107 / 1122
页数:16
相关论文
共 80 条
[51]   Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads [J].
Paniagua, D ;
Aldrich, HR ;
Lieberman, EH ;
Lamas, GA ;
Agatston, AS .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (09) :1130-+
[52]   Effect of tricuspid regurgitation and right ventricular dysfunction on long-term mortality in patients undergoing cardiac devices implantation: >10-year follow-up study [J].
Papageorgiou, Nikolaos ;
Falconer, Debbie ;
Wyeth, Nikolas ;
Lloyd, Guy ;
Pellerin, Denis ;
Speechly-Dick, Elsya ;
Segal, Oliver R. ;
Lowe, Martin ;
Rowland, Edward ;
Lambiase, Pier D. ;
Chow, Anthony W. ;
Bhattacharyya, Sanjeev .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 319 :52-56
[53]   Transvenous Extraction of Pacemaker and Defibrillator Leads and the Risk of Tricuspid Valve Regurgitation [J].
Park, Seung-Jung ;
Gentry, James L. ;
Varma, Niraj ;
Wazni, Oussama ;
Tarakji, Khaldoun G. ;
Mehta, Anand ;
Mick, Stephanie ;
Grimm, Richard ;
Wilkoff, Bruce L. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (11) :1421-1428
[54]   Tricuspid valve repair in the presence of a permanent ventricular pacemaker lead [J].
Pfannmueller, Bettina ;
Hirnle, Gregor ;
Seeburger, Joerg ;
Davierwala, Piroze ;
Schroeter, Thomas ;
Borger, Michael Andrew ;
Mohr, Friedrich Wilhelm .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (05) :657-661
[55]   Transcatheter treatment for tricuspid valve disease [J].
Praz, Fabien ;
Muraru, Denisa ;
Kreidel, Felix ;
Lurz, Philipp ;
Hahn, Rebecca T. ;
Delgado, Victoria ;
Senni, Michele ;
von Bardeleben, Ralph Stephan ;
Nickenig, Georg ;
Hausleiter, Jorg ;
Mangieri, Antonio ;
Zamorano, Jose L. ;
Prendergast, Bernard D. ;
Maisano, Francesco .
EUROINTERVENTION, 2021, 17 (10) :791-+
[56]   Morphologic Types of Tricuspid Regurgitation Characteristics and Prognostic Implications [J].
Prihadi, Edgard A. ;
Delgado, Victoria ;
Leon, Martin B. ;
Enriquez-Sarano, Maurice ;
Topilsky, Yan ;
Bax, Jeroen J. .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (03) :491-499
[57]   Permanent pacemaker implantation technique: part II [J].
Rajappan, Kim .
HEART, 2009, 95 (04) :334-342
[58]   Complex Tricuspid Valve Repair in Patients With Pacer Defibrillator-Related Tricuspid Regurgitation [J].
Raman, Jaishankar ;
Sugeng, Lissa ;
Lai, David T. M. ;
Jeevanandam, Valluvan .
ANNALS OF THORACIC SURGERY, 2016, 101 (04) :1599-1601
[59]   Institutional Variation in Quality of Cardiovascular Implantable Electronic Device Implantation A Cohort Study [J].
Ranasinghe, Isuru ;
Labrosciano, Clementine ;
Horton, Dennis ;
Ganesan, Anand ;
Curtis, Jeptha P. ;
Krumholz, Harlan M. ;
McGavigan, Andrew ;
Hossain, Sadia ;
Air, Tracy ;
Hariharaputhiran, Saranya .
ANNALS OF INTERNAL MEDICINE, 2019, 171 (05) :309-+
[60]   Pacemaker-induced tricuspid regurgitation is uncommon immediately post-implantation [J].
Rothschild, Daniel P. ;
Goldstein, James A. ;
Kerner, Nathan ;
Abbas, Amr E. ;
Patel, Meet ;
Wong, Wai Shun .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (03) :281-287