Tricuspid Regurgitation Related to Cardiac Implantable Electronic Devices: An Integrative Review

被引:39
作者
Gelves-Meza, Julian [1 ]
Lang, Roberto M. [2 ]
Valderrama-Achury, Maria Daniela [3 ]
Luis Zamorano, Jose [4 ]
Vargas-Acevedo, Catalina [5 ]
Manuel Medina, Hector [6 ]
Salazar, Gabriel [3 ]
机构
[1] Univ Rosario, Escuela Med & Ciencias Salud, Echocardiog Lab, Fdn Cardioinfantil,Inst Cardiol, Bogota, Colombia
[2] Univ Chicago Med, Cardiac Imaging Ctr, Dept Med, Sect Cardiol, Chicago, IL USA
[3] Inst Cardiol, Echocardiog Lab, Fdn Cardioinfantil, Calle 163a,13B-60,Bldg 1,10th Floor, Bogota, Colombia
[4] Hosp Univ Ramon y Cajal, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, Inst Salud Carlos III, Sect Cardiol, Madrid, Spain
[5] Inst Cardiol, Fdn Cardioinfantil, Inst Congenital Heart Dis, Bogota, Colombia
[6] Inst Cardiol, Fdn Cardioinfantil, Cardiac Imaging, Bogota, Colombia
关键词
Tricuspid regurgitation; Artificial cardiac pacing; 3D echocardiography; Device lead; Right ventricular dysfunction; NATIVE VALVULAR REGURGITATION; TRANSVENOUS LEAD EXTRACTION; TERM-FOLLOW-UP; CARDIOVERTER-DEFIBRILLATOR; PERMANENT PACEMAKER; VALVE REGURGITATION; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; CLINICAL UTILITY;
D O I
10.1016/j.echo.2022.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of cardiac implantable electronic devices, including permanent pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy, has dramatically increased in recent years. The interaction between the device lead and tricuspid valve leaflets is a potential cause of tricuspid regurgitation that in turn has an impact on morbidity and mortality. Echocardiography is necessary to grade tricuspid regurgitation severity. The use of three-dimensional imaging helps determine whether the device lead is interfering with normal leaflet coaptation. Early identification of lead-related tricuspid regurgitation is critical to select the optimal treatment, which may include lead extraction or even tricuspid valve repair or replacement in severe cases. The aims of this review are to provide a thorough assessment of the evidence about lead-associated tricuspid regurgitation and the benefits of using three-dimensional echocardiography with some technical considerations and to propose a treatment algorithm.
引用
收藏
页码:1107 / 1122
页数:16
相关论文
共 80 条
[1]   Effects of tricuspid valve regurgitation on clinical and echocardiographic outcome in patients with cardiac resynchronization therapy [J].
Abu Sham'a, Raed ;
Buber, Jonathan ;
Grupper, Avishay ;
Nof, Eyal ;
Kuperstein, Rafael ;
Luria, David ;
Feinberg, Micha S. ;
Eldar, Michael ;
Glikson, Michael .
EUROPACE, 2013, 15 (02) :266-272
[2]   Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation [J].
Addetia, Karima ;
Harb, Serge C. ;
Hahn, Rebecca T. ;
Kapadia, Samir ;
Lang, Roberto M. .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (04) :622-636
[3]   Impact of Implantable Transvenous Device Lead Location on Severity of Tricuspid Regurgitation [J].
Addetia, Karima ;
Maffessanti, Francesco ;
Mediratta, Anuj ;
Yamat, Megan ;
Weinert, Lynn ;
Moss, Joshua D. ;
Nayak, Hemal M. ;
Burke, Martin C. ;
Patel, Amit R. ;
Kruse, Eric ;
Jeevanandam, Valluvan ;
Mor-Avi, Victor ;
Lang, Roberto M. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (11) :1164-1175
[4]   Tricuspid Regurgitation and Implantable Devices [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Rajeswaran, Jeevanantham ;
Bhargava, Mandeep ;
Wazni, Oussama ;
Wilkoff, Bruce ;
Tuzcu, Emin Murat ;
Martin, David ;
Thomas, James ;
Blackstone, Eugene ;
Kapadia, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (02) :259-266
[5]   Tricuspid Regurgitation in Patients With Pacemakers and Implantable Cardiac Defibrillators: A Comprehensive Review [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Bhargava, Mandeep ;
Dunn, Justin ;
Wazni, Oussama ;
Tuzcu, E. Murat ;
Stewart, William ;
Kapadia, Samir R. .
CLINICAL CARDIOLOGY, 2013, 36 (05) :249-254
[6]   Lead-Specific Features Predisposing to the Development of Tricuspid Regurgitation After Endocardial Lead Implantation [J].
Anvardeen, Kalilur ;
Rao, Rajeev ;
Hazra, Samir ;
Hay, Karen ;
Dai, Hongyan ;
Stoyanov, Nik ;
Birnie, David ;
Dwivedi, Girish ;
Chan, Kwan Leung .
CJC OPEN, 2019, 1 (06) :316-323
[7]   Effects of pacemaker and implantable cardioverter defibrillator electrodes on tricuspid regurgitation and right sided heart functions [J].
Arabi, Peyman ;
Ozer, Necla ;
Ates, Ahmet Hakan ;
Yorgun, Hikmet ;
Oto, Ali ;
Aytemir, Kudret .
CARDIOLOGY JOURNAL, 2015, 22 (06) :637-644
[8]   Leadless Pacemakers and the Tricuspid Valve Can You Believe It? Can This Be True? [J].
Arkles, Jeffrey S. ;
Epstein, Andrew E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (05)
[9]   Clinical significance of increased tricuspid valve incompetence following implantation of ventricular leads [J].
Baquero, Giselle A. ;
Yadav, Pradeep ;
Skibba, Joshua B. ;
Banchs, Javier E. ;
Linton-Frazier, Latoya N. ;
Lengerich, Eugene J. ;
Samii, Soraya M. ;
Penny-Peterson, Erica ;
Wolbrette, Deborah L. ;
Luck, Jerry C. ;
Naccarelli, Gerald V. ;
Gonzalez, Mario D. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 38 (03) :197-202
[10]   Impact of Leadless Pacemaker Therapy on Cardiac and Atrioventricular Valve Function Through 12 Months of Follow-Up [J].
Beurskens, Niek E. G. ;
Tjong, Fleur V. Y. ;
de Bruin-Bon, Rianne N. A. ;
Dasselaar, Kosse J. ;
Kuijt, Wichert J. ;
Wilde, Arthur A. M. ;
Knops, Reinoud E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (05)