Sleep disturbance in patients with an implantable cardioverter defibrillator: Prevalence, predictors and impact on health status

被引:13
作者
Habibovic, M. [1 ,2 ]
Mudde, L. [1 ]
Pedersen, S. S. [3 ,4 ]
Schoormans, D. [1 ]
Widdershoven, J. [1 ,2 ]
Denollet, J. [1 ]
机构
[1] Tilburg Univ, Dept Med & Clin Psychol, Tilburg, Netherlands
[2] Elisabeth TweeSteden Hosp, Dept Cardiol, Tilburg, Netherlands
[3] Univ Southern Denmark, Dept Psychol, Odense, Denmark
[4] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
关键词
Sleep disturbance; implantable cardioverter defibrillator; health status; negative affectivity; QUALITY-OF-LIFE; AMERICAN-HEART-ASSOCIATION; D PERSONALITY; NEGATIVE AFFECTIVITY; SCIENTIFIC STATEMENT; DISTRESS; VALIDITY; ANXIETY; OUTCOMES; DISEASE;
D O I
10.1177/1474515117748931
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sleep disturbances are highly prevalent in patients with cardiac diseases and associated with poor health outcomes. However, little is known about sleep disturbance in patients with an implantable cardioverter defibrillator. Aims: We examined the prevalence and predictors of sleep disturbance and the impact on perceived health status in a Dutch cohort of implantable cardioverter defibrillator patients. Methods: Patients (n=195) enrolled in the Web-based distress program for implantable cardioverter defibrillator patients (WEBCARE) trial completed questionnaires at the time of implantable cardioverter defibrillator implantation, three, six and 12 months afterwards. Sleep disturbance was assessed with the corresponding item #3 of the Patient Health Questionnaire 9. Results: At baseline, 67% (n=130) reported sleep disturbance (cut off 1). One year later, the prevalence was 57% (n=112). Younger age (odds ratio=0.96, 95% confidence interval 0.92-0.99; p=0.012) and high negative affectivity/low social inhibition (odds ratio=4.47, 95% confidence interval 1.52-13.17; p=0.007) were associated with sleep disturbance at 12 months in adjusted analyses. Sleep disturbance was not associated with health status at 12 months. Charlson Comorbidity Index, anxiety, Type D personality and high negative affectivity/low social inhibition were associated with impaired health status at follow-up. Conclusions: Sleep disturbance was highly prevalent in patients with an implantable cardioverter defibrillator. Younger age and high negative affectivity predicted sleep disturbance 12 months post-implantation independent of other demographic, clinical, intervention and psychological covariates. Sleep disturbance was not associated with impaired health status at the 12-month follow-up.
引用
收藏
页码:390 / 398
页数:9
相关论文
共 34 条
[1]   The association of sleep-disordered breathing and sleep symptoms with quality of life in the sleep heart health study [J].
Baldwin, CM ;
Griffith, KA ;
Nieto, FJ ;
O'Connor, GT ;
Walsleben, JA ;
Redline, S .
SLEEP, 2001, 24 (01) :96-105
[2]   Sleep Quality and Sleepiness in Persons with Implantable Cardioverter Defibrillators: Outcome from a Clinical Randomized Longitudinal Trial [J].
Berg, Selina Kikkenborg ;
Higgins, Melinda ;
Reilly, Carolyn M. ;
Langberg, Jonathan J. ;
Dunbar, Sandra B. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (04) :431-443
[3]   A comparative study of uncertainty, optimism and anxiety in patients receiving their first implantable defibrillator for primary or secondary prevention of sudden cardiac death [J].
Carroll, Sandra L. ;
Arthur, Heather M. .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (07) :836-845
[4]   Type D personality is associated with sleep problems in adolescents. Results from a population-based cohort study of Swedish adolescents [J].
Conden, Emelie ;
Ekselius, Lisa ;
Aslund, Cecilia .
JOURNAL OF PSYCHOSOMATIC RESEARCH, 2013, 74 (04) :290-295
[5]   Comparison of Actigraphic and Subjective Measures of Sleep in Implantable Cardioverter Defibrillator and Coronary Artery Disease Patients [J].
Cross, Natalie J. ;
McCrae, Christina S. ;
Smith, Karen M. ;
Conti, Jamie B. ;
Sears, Samuel F. .
CLINICAL CARDIOLOGY, 2010, 33 (12) :753-759
[6]   DS14: Standard assessment of negative affectivity, social inhibition, and Type D personality [J].
Denollet, J .
PSYCHOSOMATIC MEDICINE, 2005, 67 (01) :89-97
[7]   Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator [J].
Denollet, Johan ;
Tekle, Fetene B. ;
Pedersen, Susanne S. ;
van der Voort, Pepijn H. ;
Alings, Marco ;
van den Broek, Krista C. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (06) :2705-2709
[8]   Comparison of patient and partner quality of life and health outcomes in the first year after an implantable cardioverter defibrillator (ICD) [J].
Dougherty, Cynthia M. ;
Fairbanks, Allison M. ;
Eaton, Linda H. ;
Morrison, Megan L. ;
Kim, Mi Sun ;
Thompson, Elaine A. .
JOURNAL OF BEHAVIORAL MEDICINE, 2016, 39 (01) :94-106
[9]  
European Heart Rhythm Association, 2006, J Am Coll Cardiol, V48, pe247, DOI 10.1016/j.jacc.2006.07.010
[10]  
Fortunato VJ, 2006, PERS INDIV DIFFER, V41, P11