Comparison of speech perception benefits with SPEAK and ACE coding strategies in pediatric Nucleus CI24M cochlear implant recipients

被引:16
|
作者
Pasanisi, E
Bacciu, A
Vincenti, V
Guida, M
Berghenti, MT
Barbot, A
Panu, F
Bacciu, S
机构
[1] Univ Parma, Dept Otolaryngol, I-43100 Parma, Italy
[2] SS Trinita Hosp, Dept Otolaryngol, Cagliari, Italy
关键词
cochlear implant; children; speech coding strategy;
D O I
10.1016/S0165-5876(02)00075-7
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Nine congenitally deaf children who received a Nucleus CI24M cochlear implant and who were fitted with the SPrint speech processor participated in this study. All subjects were initially programmed with the SPEAK coding strategy and then converted to the ACE strategy. Speech perception was evaluated before and after conversion to the now coding strategy using word and Common Phrase speech recognition tests in both the presence and absence of noise. In quiet conditions, the mean percent correct scores for words were 68.8% with SPEAK and 91% with ACE; for phrases the percentage was 66.6% with SPEAK and 85.5% with ACE. In the presence of noise (at + 10 dB signal-to-noise ratio), the mean percent correct scores for words were 43.3% with SPEAK compared to 84.4% with ACE; for phrases the percentage was 41.1% with SPEAK and 82.2% with ACE. Statistical analysis revealed significant improvement in open-set speech recognition with ACE compared to SPEAK. Preliminary data suggest that converting children from SPEAK to the ACE strategy improves their performance. Subjects showed significant improvements for open-set word and sentence recognition in quiet as well as in noise when ACE was used in comparison with SPEAK. The greatest improvements were obtained when tests were presented in the presence of noise. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 23 条
  • [1] Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the nucleus CI 24M cochlear implant system
    Kiefer, J
    Hohl, S
    Stürzebecher, E
    Pfennigdorff, T
    Gstöettner, W
    AUDIOLOGY, 2001, 40 (01): : 32 - 42
  • [2] Neural response telemetry with the nucleus CI24M cochlear implant
    Shallop, JK
    Facer, GW
    Peterson, A
    LARYNGOSCOPE, 1999, 109 (11): : 1755 - 1759
  • [3] Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, M
    Forli, F
    Berrettini, S
    Bacciu, S
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) : 1155 - 1158
  • [4] Electrical impedance measurements with the CI24M cochlear implant for a child with Mondini dysplasia
    French, ML
    BRITISH JOURNAL OF AUDIOLOGY, 1999, 33 (01): : 61 - 66
  • [5] Results from a pilot study using the Nucleus CI24M/SP5 cochlear implant system
    Lai, WK
    Dillier, N
    Laszig, R
    Fisch, U
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (06): : S35 - S36
  • [6] Speech Perception and Audiometry Thresholds in Nucleus Cochlear 22 and Nucleus 24 Implant Users
    Samuel, Paola Angelica
    Schmidt Goffi Gomez, Maria Valeria
    Befi Lopes, Debora Maria
    Matas, Carla Gentile
    Tsuji, Robinson Koji
    de Brito Neto, Rubens Vuono
    Bento, Ricardo Ferreira
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2010, 14 (03) : 331 - 337
  • [7] Effects of Segmental and Suprasegmental Speech Perception on Reading in Pediatric Cochlear Implant Recipients
    Grantham, Heather
    Davidson, Lisa S.
    Geers, Ann E.
    Uchanski, Rosalie M.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2022, 65 (09): : 3583 - 3594
  • [8] Normative findings of electrically evoked compound action potential measurements uing the neural response telemetry of the nucleus CI24M cochlear implant system
    Dees, DC
    Dillier, N
    Lai, WK
    von Wallenberg, E
    van Dijk, B
    Akdas, F
    Aksit, M
    Batman, C
    Beynon, A
    Burdo, S
    Chanal, JM
    Collet, L
    Conway, M
    Coudert, C
    Craddock, L
    Cullington, H
    Deggouj, N
    Fraysse, B
    Grabel, S
    Kiefer, J
    Kiss, JG
    Lenarz, T
    Mair, A
    Maune, S
    Müller-Deile, J
    Piron, JP
    Razza, S
    Tasche, C
    Thai-Van, H
    Toth, F
    Truy, E
    Uziel, A
    Smoorenburg, GF
    AUDIOLOGY AND NEURO-OTOLOGY, 2005, 10 (02) : 105 - 116
  • [9] Spectral Modulation Detection Performance and Speech Perception in Pediatric Cochlear Implant Recipients
    Davidson, Lisa S.
    Geers, Ann E.
    Uchanski, Rosalie M.
    AMERICAN JOURNAL OF AUDIOLOGY, 2021, 30 (04) : 1076 - 1087
  • [10] The Effect of Interdevice Interval on Speech Perception Performance Among Bilateral, Pediatric Cochlear Implant Recipients
    Kocdor, Pelin
    Iseli, Claire E.
    Teagle, Holly F.
    Woodard, Jennifer
    Park, Lisa
    Zdanski, Carlton J.
    Brown, Kevin D.
    Adunka, Oliver F.
    Buchman, Craig A.
    LARYNGOSCOPE, 2016, 126 (10): : 2389 - 2394