PurposeDirect 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. MethodsThe proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. ResultsReal-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P<0.0005), and significantly improved vessel sharpness, myocardial suppression, and image quality (P<0.05). ConclusionThis demonstrates the feasibility of a 3D SSFP coronary magnetic resonance angiography sequence using a 2D epicardial fat image as a navigator for real-time prospective motion tracking. Magn Reson Med 71:599-607, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 31 条
  • [1] 3D Radial Sampling and 3D Affine Transform-based Respiratory Motion Correction Technique for Free-breathing Whole-Heart Coronary MRA with 100% Imaging Efficiency
    Bhat, Himanshu
    Ge, Lan
    Nielles-Vallespin, Sonia
    Zuehlsdorff, Sven
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1269 - 1277
  • [2] Prospective navigator correction of image position for coronary MR angiography
    Danias, PG
    McConnell, MV
    Khasgiwala, VC
    Chuang, ML
    Edelman, RR
    Manning, WJ
    [J]. RADIOLOGY, 1997, 203 (03) : 733 - 736
  • [3] Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography
    Dewan, Maneesh
    Hager, Gregory D.
    Lorenz, Christine H.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 604 - 615
  • [4] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Du, YPP
    McVeigh, ER
    Bluemke, DA
    Silber, HA
    Foo, TKF
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 287 - 294
  • [5] Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms
    Etienne, A
    Botnar, RM
    van Muiswinkel, AMC
    Boesiger, P
    Manning, WJ
    Stuber, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 658 - 666
  • [6] Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    Henningsson, Markus
    Smink, Jouke
    Razavi, Reza
    Botnar, Rene M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 486 - 494
  • [7] Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    Henningsson, Markus
    Koken, Peter
    Stehning, Christian
    Razavi, Reza
    Prieto, Claudia
    Botnar, Rene M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 437 - 445
  • [8] Jhooti P, 2000, MAGN RESON MED, V43, P470, DOI 10.1002/(SICI)1522-2594(200003)43:3<470::AID-MRM20>3.0.CO
  • [9] 2-U
  • [10] Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging
    Keegan, J
    Gatehouse, P
    Yang, GZ
    Firmin, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 476 - 481