Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization

被引:82
作者
Nyan, M. N. [1 ]
Tay, F. E. H. [1 ]
Tan, A. W. Y. [1 ]
Seah, K. H. W. [1 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, Singapore 119260, Singapore
关键词
normal activities; fall activities; fainting; sideways and backward falls; elderly;
D O I
10.1016/j.medengphy.2005.11.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Distinguishing sideways and backward falls from normal activities of daily living using angular rate sensors (gyroscopes) was explored in this paper. Gyroscopes were secured on a shirt at the positions of sternum (S), front of the waist (FW) and right underarm (RU) to measure angular rate in lateral and sagittal planes of the body during falls and normal activities. Moreover, the motions of the fall incidents were captured by a high-speed camera at a frame rate of 250 frames per second (fps) to study the body configuration during fall. The high-speed camera and the sensor data capture system were activated simultaneously to synchronize the picture frame of high-speed camera and the sensor data. The threshold level for each sensor was set to distinguish fall activities from normal activities. Lead time of fall activities (time after threshold value is surpassed to the time when the hip hits the ground) and relative angle of body configuration (angle beta between the vertical line and the line from the center point of the foot or the center point between the two legs to that of the waist) at the threshold level were studied. For sideways falls, lead times of sensors at positions FW and S were about 200-220 ms and 135-182 ms, respectively. The lead time of the slippery backward fall (about 98 ms) from the sensor at position RU was shorter than that of the sideways falls from the sensors at positions FW and S. The relative angle of body configuration at threshold level for sideways and backward falls were about 40-43 degrees for the sensor at position FW, about 43-52 degrees for the sensor at position S and about 54 degrees for the sensor at position RU, respectively. This is the first study that investigates fall dynamics in detection of fall before the person hits the ground using angular rate sensors (gyroscopes). (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:842 / 849
页数:8
相关论文
共 20 条
[1]  
Cassel CK, 1990, GERIATR MED, V2nd, P528
[2]   FALL SEVERITY AND BONE-MINERAL DENSITY AS RISK-FACTORS FOR HIP FRACTURE IN AMBULATORY ELDERLY [J].
GREENSPAN, SL ;
MYERS, ER ;
MAITLAND, LA ;
RESNICK, NM ;
HAYES, WC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (02) :128-133
[3]   Fall direction, bone mineral density, and function: Risk factors for hip fracture in frail nursing home elderly [J].
Greenspan, SL ;
Myers, ER ;
Kiel, DP ;
Parker, RA ;
Hayes, WC ;
Resnick, NM .
AMERICAN JOURNAL OF MEDICINE, 1998, 104 (06) :539-545
[4]  
Gross Y T, 1990, J Gerontol Nurs, V16, P20
[5]   IMPACT NEAR THE HIP DOMINATES FRACTURE RISK IN ELDERLY NURSING-HOME RESIDENTS WHO FALL [J].
HAYES, WC ;
MYERS, ER ;
MORRIS, JN ;
GERHART, TN ;
YETT, HS ;
LIPSITZ, LA .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (03) :192-198
[6]   Classification of basic daily movements using a triaxial accelerometer [J].
Mathie, MJ ;
Celler, BG ;
Lovell, NH ;
Coster, ACF .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (05) :679-687
[7]   Impact forces following the unexpected removal of a chair while sitting [J].
McGill, SM ;
Callaghan, JP .
ACCIDENT ANALYSIS AND PREVENTION, 1999, 31 (1-2) :85-89
[8]  
MELINDA M, 2002, PREV MED, V34, P546
[9]   TYPE OF FALL AND RISK OF HIP AND WRIST FRACTURES - THE STUDY OF OSTEOPOROTIC FRACTURES [J].
NEVITT, MC ;
CUMMINGS, SR ;
BLACK, D ;
GENANT, HK ;
ARNAUD, C ;
BROWNER, W ;
FAULKER, K ;
FOX, C ;
GLUER, C ;
HARVEY, S ;
HULLEY, SB ;
PALERMO, L ;
SEELEY, D ;
STEIGER, P ;
JERGAS, M ;
SHERWIN, R ;
SCOTT, J ;
FOX, K ;
LEWIS, J ;
BAHR, M ;
TRUSTY, S ;
HOHMAN, B ;
EMERSON, L ;
REBAR, D ;
OLINER, E ;
ENSRUD, K ;
GRIMM, R ;
BELL, C ;
THOMAS, D ;
JACOBSON, K ;
JACKSON, S ;
MITSON, E ;
STOCKE, L ;
FRANK, P ;
CAULEY, JA ;
KULLER, LH ;
HARPER, L ;
NASIM, M ;
BASHADA, C ;
BUCK, L ;
GITHENS, A ;
MEDVE, D ;
RUDOVSKY, S ;
VOGT, TM ;
VOLLMER, VM ;
GLAUBER, H ;
ORWOLL, E ;
BLANK, J ;
MASTELSMITH, B ;
BRIGHT, R .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1993, 41 (11) :1226-1234
[10]   Monitoring behavior in home using a smart fall sensor and position sensors [J].
Noury, N ;
Hervé, T ;
Rialle, V ;
Virone, G ;
Mercier, E ;
Morey, G ;
Moro, A ;
Porcheron, T .
1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, :607-610