Stochastic Evaluation of Disinfection Performance in Large-Scale Open-Channel UV Photoreactors

被引:8
作者
Ahmed, Yousra M. [1 ]
Ortiz, Angela P. [2 ]
Blatchley, Ernest R., III [1 ,3 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[2] 2 CDM Smith,800 Brickell Ave, Miami, FL 33131 USA
[3] Purdue Univ, Div Environm & Ecol Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
关键词
UV disinfection; Open channel; Stochastic; Monte Carlo; Variability; Dose response; E; coli; Coliphage MS2; WATER DISINFECTION; REACTOR; FLOW; DISTRIBUTIONS; INACTIVATION; SIMULATION;
D O I
10.1061/(ASCE)EE.1943-7870.0001562
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Numerical models based on integrated applications of computational fluid dynamics and fluence rate field models (CFD-I models) are often used to simulate process performance in ultraviolet (UV) disinfection systems and other photoreactors. However, the predictions of these models are often presented as deterministic endpoints, whereas actual performance in these systems is variable. The central hypothesis of this research was that CFD-I models can be applied via a stochastic approach [Monte Carlo (MC) simulations] to simulate process performance of large-scale UV disinfection reactors including variability, by allowing appropriate variations in input variables, including UV dose-response behavior of target or challenge microbes, as well as the initial microbial count. The results of these stochastic simulations indicated that variability in E. coli dose-response model parameters and initial viable E. coli concentration play important roles in the variability among predictions of disinfection efficacy. MC simulation predictions indicated that the likelihood of violating the regulatory permits for viable E. coli concentration for a large-scale UV disinfection system was negligible for many operating conditions that span the range of common use, which suggests that it may be possible to reduce the amount of UV power applied in treatment, hence reducing input electrical power while retaining compliance with treatment objectives.
引用
收藏
页数:13
相关论文
共 45 条
[1]  
Ahmed Y. M. M., 2017, THESIS
[2]   Ray Tracing for Fluence Rate Simulations in Ultraviolet Photoreactors [J].
Ahmed, Yousra M. ;
Jongewaard, Mark ;
Li, Mengkai ;
Blatchley, Ernest R., III .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2018, 52 (08) :4738-4745
[3]  
[Anonymous], 2007, INTRO COPULAS, DOI DOI 10.1007/0-387-28678-0
[4]  
[Anonymous], 2010, CAMBRIDGE DICT STAT
[5]  
[Anonymous], ULTR DIS GUID MAN FI
[6]  
[Anonymous], 2014, Thesis
[7]   The comparison of discrete ordinate and Monte Carlo methods in solving of the radiation transfer equations in a heterogenous reactor [J].
Asadollahfardi, G. ;
Noori, M. ;
Asadi, M. ;
Taherioun, M. .
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2018, 67 (01) :109-118
[8]   Validation of large-scale, monochromatic UV disinfection systems for drinking water using dyed microspheres [J].
Blatchley, E. R., III ;
Shen, C. ;
Scheible, O. K. ;
Robinson, J. P. ;
Ragheb, K. ;
Bergstrom, D. E. ;
Rokjer, D. .
WATER RESEARCH, 2008, 42 (03) :677-688
[9]   Numerical modelling of UV intensity: Application to collimated-beam reactors and continuous-flow systems [J].
Blatchley, ER .
WATER RESEARCH, 1997, 31 (09) :2205-2218
[10]   Process modeling of ultraviolet disinfection [J].
Blatchley, ER ;
Do-Quang, Z ;
Janex, ML ;
Laîné, JM .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (06) :63-69