A Multi-channel ASIC for the Readout of the HICAM Gamma Camera

被引:0
|
作者
Gola, A. [1 ]
Bombelli, L. [1 ]
Fiorini, C. [1 ]
Frizzi, T. [1 ]
Membretti, G. [1 ]
Nava, R. [1 ]
Peloso, R. [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron & Informaz, I-20133 Milan, Italy
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
SILICON DRIFT DETECTORS; X-RAY SPECTROSCOPY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the HICAM project is to build a compact, high-resolution gamma-ray imager for human patients, designed according to the Anger Camera principle. The imager is based on an array of 10 x 10 Silicon Drift Detectors, coupled to a single CsI:Tl scintillator. The array of photo detectors is read out by four 25-channel ASICs, which are the subject of this paper. Each channel of the ASIC features a low-noise preamplifier, compatible with the pulsed reset mode of the SDD, a gain stage, a high order semi-Gaussian shaping amplifier with selectable peaking times, a baseline holder and a peak stretcher. The ASIC also contains a 25:1 analog multiplexer, a digital section and a differential ADC driver. The pulsed reset mode of the preamplifier, which reduces the parallel noise of the system, is particularly well suited for the use with long shaping times, which are required by the CsI:Tl scintillator, due to its long primary decay time constant. The ASIC, however, features peaking times ranging from 1.1 mu s up to 11 mu s, optimized for both X-ray direct conversion measurements and for gamma-ray measurements with LaBr(3):Ce and CsI:Tl. In the paper we describe the design and the first experimental characterization of the ASIC, together with a test SDD. With an ultra-low noise test SDD we have measured an energy resolution of 130 eV FWHM at the Mn K alpha line, showing that the ASIC has a good potential for high resolution gamma-spectroscopy.
引用
收藏
页码:1085 / 1089
页数:5
相关论文
共 50 条
  • [1] Development of the analog ASIC for multi-channel readout X-ray CCD camera
    Nakajima, Hiroshi
    Matsuura, Daisuke
    Idehara, Toshihiro
    Anabuki, Naohisa
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Katayama, Haruyoshi
    Kitamura, Hisashi
    Uchihori, Yukio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 632 (01): : 128 - 132
  • [2] Multi-Channel Readout ASIC for ToF-PET
    Fischer, Peter
    Peric, Ivan
    Ritzert, Michael
    Solf, Torsten
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2523 - 2527
  • [3] The HICAM Gamma Camera
    Fiorini, C.
    Busca, P.
    Peloso, R.
    Abba, A.
    Geraci, A.
    Bianchi, C.
    Poli, G. L.
    Virotta, G.
    Erlandsson, K.
    Hutton, B. F.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    Pedretti, A.
    Van Mullekom, P.
    Ottobrini, L.
    Lucignani, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 537 - 544
  • [4] The HICAM Gamma Camera
    Peloso, R.
    Busca, P.
    Fiorini, C.
    Abba, A.
    Geraci, A.
    Manenti, A.
    Longoni, A.
    Padovini, G.
    Bianchi, C.
    Poli, G. L.
    Erlandsson, K.
    Hutton, B. F.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    Pedretti, A.
    Van Mullekom, P.
    Pallaro, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1957 - 1960
  • [5] Multi-channel charge readout ASIC for X-ray detection
    Liu H.
    Xu L.
    Tian T.
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2021, 48 (04): : 97 - 102and112
  • [6] Applications of the HICAM Gamma Camera
    Busca, P.
    Peloso, R.
    Fiorini, C.
    Gola, A.
    Abba, A.
    Erlandsson, K.
    Hutton, B. F.
    Bianchi, C.
    Poli, G. L.
    Guerra, U.
    Virotta, G.
    Ottobrini, L.
    Martelli, C.
    Lucignani, G.
    Pedretti, A.
    Van Mullekom, P.
    Incorvaia, S.
    Perotti, F.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2104 - 2107
  • [7] PETA4: a multi-channel TDC/ADC ASIC for SiPM readout
    Sacco, I.
    Fischer, P.
    Ritzert, M.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [8] Fast Readout of Multi-Channel Detectors by Using a CCD/CMOS Camera
    Shayduk, Maxim
    Mirzoyan, Razmik
    Polyakova, Alisja
    Schweizer, Thomas
    Lorenz, Eckart
    Teshima, Masahiro
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 49 - 51
  • [9] A new to readout multi-channel
    Chiarelli, Giorgio
    Cucinotta, Martina
    Leone, Sandra
    Morsani, Fabio
    Scuri, Fabrizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [10] VERITAS 2.0 a multi-channel readout ASIC suitable for the DEPFET arrays of the WFI for Athena
    Porro, Matteo
    Bianchi, Davide
    De Vita, Giulio
    Herrmann, Sven
    Wassatsch, Andreas
    Baehr, Alexander
    Bergbauer, Bettina
    Meidinger, Norbert
    Ott, Sabine
    Treis, Johannes
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144