Intensity-modulated radiation therapy dose verification using fluence and portal imaging device

被引:9
|
作者
Sumida, Iori [1 ]
Yamaguchi, Hajime [2 ]
Das, Indra J. [3 ]
Kizaki, Hisao [2 ]
Aboshi, Keiko [2 ]
Tsujii, Mari [2 ]
Yamada, Yuji [2 ]
Suzuki, Osamu [1 ]
Seo, Yuji [1 ]
Isohashi, Fumiaki [1 ]
Ogawa, Kazuhiko [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, Suita, Osaka 5650871, Japan
[2] NTT West Osaka Hosp, Dept Radiat Oncol, Tennoji Ku, Osaka, Japan
[3] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 01期
关键词
IMRT; EPID; dose reconstruction; fluence-based dose calculation; QA; EPID DOSIMETRY; IMRT VERIFICATION; QUALITY-ASSURANCE; PASSING RATES; RECONSTRUCTION; PATIENT; QA; RESOLUTION; FIELDS; IMAGES;
D O I
10.1120/jacmp.v17i1.5899
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient-specific quality assurance for intensity-modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated for 10 head and neck IMRT cases. The fluence map of each beam was exported from the TPS and EPID images of the treatment beams were acquired. Measured EPID images were deconvolved to the incident fluence with proper corrections. The relative error distribution between the TPS fluence map and the incident fluence from the EPID was created. This was also created for a 2D diode array detector. The absolute point dose was measured with an ionization chamber, and the dose distribution was measured by a radiochromic film. In three cases, MLC leaf positions were intentionally changed to create the dose error as much as 5% against the planned dose and our fluence-based method was tested using gamma index. Absolute errors between the predicted dose of 2D diode detector and of our method and measurements were 1.26% +/- 0.65% and 0.78% +/- 0.81% respectively. The gamma passing rate (3% global / 3 mm) of the TPS was higher than that of the 2D diode detector (p< 0.02), and lower than that of the EPID (p < 0.04). The gamma passing rate (2% global / 2 mm) of the TPS was higher than that of the 2D diode detector, while the gamma passing rate of the TPS was lower than that of EPID (p < 0.02). For three modified plans, the predicted dose errors against the measured dose were 1.10%, 2.14%, and -0.87%. The predicted dose distributions from the EPID were well matched to the measurements. Our fluence-based method provides very accurate dosimetry for IMRT patients. The method is simple and can be adapted to any clinic for complex cases.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 50 条
  • [1] A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions
    Renner, WD
    Sarfaraz, M
    Earl, MA
    Yu, CX
    MEDICAL PHYSICS, 2003, 30 (11) : 2996 - 3005
  • [2] Relative profile and dose verification of intensity-modulated radiation therapy
    Chang, JW
    Mageras, GS
    Chui, CS
    Ling, CC
    Lutz, W
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01): : 231 - 240
  • [3] Gel-layer dosimetry for dose verification in intensity-modulated radiation therapy
    Tomatis, S.
    Carrara, M.
    Gambarini, G.
    Marchesini, R.
    Valente, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 506 - 509
  • [4] Dose reconstruction for intensity-modulated radiation therapy using a non-iterative method and portal dose image
    Yeo, Inhwan Jason
    Jung, Jae Won
    Chew, Meng
    Kim, Jong Oh
    Wang, Brian
    DiBiase, Steven
    Zhu, Yunping
    Lee, Dohyung
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17): : 5223 - 5236
  • [5] Computer verification of fluence map for intensity modulated radiation therapy
    Xing, L
    Li, JG
    MEDICAL PHYSICS, 2000, 27 (09) : 2084 - 2092
  • [6] Verification system for intensity-modulated radiation therapy with scintillator
    Ando, Yasuharu
    Miki, Kentaro
    Araki, Jun
    Tsuneda, Masato
    Kiriu, Hiroshi
    Nishio, Teiji
    Nagata, Yasushi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 9 - 21
  • [7] In vivo dosimetric verification of intensity-modulated radiation therapy
    Chytyk-Praznik, K.
    Van Uytven, E.
    Van Beek, T.
    McCurdy, B. M. C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4629 - 4629
  • [8] Verification system for intensity-modulated radiation therapy with scintillator
    Yasuharu Ando
    Kentaro Miki
    Jun Araki
    Masato Tsuneda
    Hiroshi Kiriu
    Teiji Nishio
    Yasushi Nagata
    Physical and Engineering Sciences in Medicine, 2021, 44 : 9 - 21
  • [9] Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
    Greer, PB
    Popescu, CC
    MEDICAL PHYSICS, 2003, 30 (07) : 1618 - 1627
  • [10] Accuracy of intensity-modulated radiation therapy dose calculations: verification based on-board conebeam CT imaging
    Tuntipumiamorn, Lalida
    Iampongpaiboon, Porntip
    Damrongkijudom, Nuanpen
    Krongyuth, Khummook
    Polwatsatian, Vinai
    Jaikreng, Satja
    ASIAN BIOMEDICINE, 2011, 5 (04) : 537 - 541