Ni(II)-quercetin complex modified multiwall carbon nanotube ionic liquid paste electrode and its electrocatalytic activity toward the oxidation of glucose

被引:100
作者
Zheng, Li [1 ,2 ]
Zhang, Jiao-qiang [3 ]
Song, Jun-feng [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Xian 710069, PR, Peoples R China
[2] Xian Shiyou Univ, Coll Chem & Chem Engn, Xian 710065, Peoples R China
[3] NW Polytech Univ, Sch Sci, Dept Appl Chem, Xian 710072, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose; Nickel; Quercetin; Multi-wall carbon nanotubes; Ionic liquids; Chemically modified electrode; Electrocatalysis; ELECTROCHEMICAL DETECTION; AMPEROMETRIC SENSOR; BIOSENSOR; QUERCETIN; ELECTROOXIDATION; CATALYSIS; MICROPARTICLES; CHROMATOGRAPHY; HYBRID;
D O I
10.1016/j.electacta.2009.03.047
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A modified electrode Ni(II)-Qu-MWCNT-IL-PE has been fabricated by electrodepositing Ni(II)-quercetin [Ni(II)-Qu] complex on the surface of multi-wall carbon nanotube ionic liquid paste electrode (MWCNT-IL-PE) in alkaline solution. The Ni(II)-Qu-MWCNT-IL-PE exhibits the characteristic of improved reversibility and enhanced current responses of the Ni(III)/Ni(II) couple compared with Ni(II)-Qu-MWCNT-PE. It also shows good electrocatalytic activity toward the oxidation of glucose. Kinetic parameters such as the electron transfer coefficient alpha, rate constant k(s) of the electrode reaction and the catalytic rate constant k(cat) of the catalytic reaction are determined. Moreover, the catalytic current presents linear dependence on the concentration of glucose from 5.0 mu M to 2.8 mM, with a detection limit of 1.0 mu M by amperometry. The modified electrode for glucose determination is of the property of simple preparation, good stability, fast response and high sensitivity. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4559 / 4565
页数:7
相关论文
共 40 条
[1]  
[Anonymous], 2007, ELECTROCHIM ACTA, DOI DOI 10.1016/J.ELECTACTA.2007.03.065
[2]  
Aoun S.B., 2004, J ELECTROANAL CHEM, V567, P175, DOI DOI 10.1016/J.JELECHEM.2003.12.022
[3]   Selective electro-oxidation of D-glucose by RuCl2(azpy)2 complexes as electrochemical mediators [J].
Bamba, K ;
Léger, JM ;
Garnier, E ;
Bachmann, C ;
Servat, K ;
Kokoh, KB .
ELECTROCHIMICA ACTA, 2005, 50 (16-17) :3341-3346
[4]   Metal complexes of the flavonoid quercetin: antibacterial properties [J].
Bravo, A ;
Anacona, JR .
TRANSITION METAL CHEMISTRY, 2001, 26 (1-2) :20-23
[5]   Highly-dispersed copper microparticles on the active gold substrate as an amperometric sensor for glucose [J].
Casella, IG ;
Gatta, M ;
Guascito, MR ;
Cataldi, TRI .
ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) :63-71
[6]   Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites [J].
Cui, Hui-Fang ;
Ye, Jian-Shan ;
Zhang, Wei-De ;
Li, Chang-Ming ;
Luong, John H. T. ;
Sheu, Fwu-Shan .
ANALYTICA CHIMICA ACTA, 2007, 594 (02) :175-183
[7]   Electrocatalytic oxidation of glucose at a Ni-curcumin modified glassy carbon electrode [J].
Elahi, M. Yousef ;
Heli, H. ;
Bathaie, S. Z. ;
Mousavi, M. F. .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2007, 11 (02) :273-282
[8]   Polypyrrole/copper hexacyanoferrate hybrid as redox mediator for glucose biosensors [J].
Fiorito, PA ;
Brett, CMA ;
de Torresi, SIC .
TALANTA, 2006, 69 (02) :403-408
[9]   Multi-wall carbon nanotube paste electrode for adsorptive stripping determination of quercetin: A comparison with graphite paste electrode via voltammetry and chronopotentiometry [J].
He, JB ;
Lin, XQ ;
Pan, J .
ELECTROANALYSIS, 2005, 17 (18) :1681-1686
[10]   A novel nanobiocomposite based glucose biosensor using neutral red functionalized carbon nanotubes [J].
Jeykumari, D. R. Shobha ;
Narayanan, S. Sriman .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (09) :1404-1411