Neuronavigation using susceptibility-weighted venography: application to deep brain stimulation and comparison with gadolinium contrast

被引:17
作者
Beriault, Silvain [1 ]
Sadikot, Abbas F. [1 ,2 ]
Alsubaie, Fahd [1 ,2 ]
Drouin, Simon [1 ,2 ]
Collins, D. Louis [1 ]
Pike, G. Bruce [3 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Montreal Neurol Inst, Dept Neurol & Neurosurg, Montreal, PQ H3A 2B4, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Dept Radiol, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
susceptibility-weighted imaging; deep brain stimulation; presurgical planning; computer-assisted intervention; functional neurosurgery; SUBTHALAMIC NUCLEUS; PARKINSONS-DISEASE; HEMORRHAGIC COMPLICATIONS; NEUROSURGERY; MRI; ANGIOGRAPHY; SURGERY; ECHOES; SWI;
D O I
10.3171/2014.3.JNS131860
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Careful trajectory planning on preoperative vascular imaging is an essential step in deep brain stimulation (DBS) to minimize risks of hemorrhagic complications and postoperative neurological deficits. This paper compares 2 MRI methods for visualizing cerebral vasculature and planning DBS probe trajectories: a single data set Ti-weighted scan with double-dose gadolinium contrast (Tlw-Gd) and a multi data set protocol consisting of a Ti-weighted structural, susceptibility-weighted venography, and time-of-flight angiography (T1w-SWI-TOF). Two neurosurgeons who specialize in neuromodulation surgery planned bilateral STN DBS in 18 patients with Parkinson's disease (36 hemispheres) using each protocol separately. Planned trajectories were then evaluated across all vascular data sets (Tlw-Gd, SWI, and TOF) to detect possible intersection with blood vessels along the entire path via an objective vesselness measure. The authors' results show that trajectories planned on Tlw-SWI-TOF successfully avoided the cerebral vasculature imaged by conventional T1w-Gd and did not suffer from missing vascular information or imprecise data set registration. Furthermore, with appropriate planning and visualization software, trajectory corridors planned on Tlw-SWI-TOF intersected significantly less fine vasculature that was not detected on the Tlw-Gd (p < 0.01 within 2 mm and p < 0.001 within 4 mm of the track centerline). The proposed Tlw-SWI-TOF protocol comes with minimal effects on the imaging and surgical workflow, improves vessel avoidance, and provides a safe costeffective alternative to injection of gadolinium contrast.
引用
收藏
页码:131 / 141
页数:11
相关论文
共 50 条
[21]   Accuracy of head ultrasound for the detection of intracranial hemorrhage in preterm neonates: Comparison with brain MRI and susceptibility-weighted imaging [J].
Intrapiromkul, Jarunee ;
Northington, Frances ;
Huisman, Thierry A. G. M. ;
Izbudak, Izlem ;
Meoded, Avner ;
Tekes, Aylin .
JOURNAL OF NEURORADIOLOGY, 2013, 40 (02) :81-88
[22]   Diagnostic Value of Fractal Analysis for the Differentiation of Brain Tumors Using 3-Tesla Magnetic Resonance Susceptibility-Weighted Imaging [J].
Di Ieva, Antonio ;
Le Reste, Pierre-Jean ;
Carsin-Nicol, Beatrice ;
Ferre, Jean-Christophe ;
Cusimano, Michael D. .
NEUROSURGERY, 2016, 79 (06) :839-845
[23]   Evaluating traumatic brain injury using conventional magnetic resonance imaging and susceptibility-weighted imaging in dogs [J].
Noh, Daji ;
Choi, Sooyoung ;
Choi, Hojung ;
Lee, Youngwon ;
Lee, Kija .
JOURNAL OF VETERINARY SCIENCE, 2019, 20 (02)
[24]   Ex vivo susceptibility-weighted imaging anatomy of canine brain-comparison of imaging and histological sections [J].
Arribarat, Germain ;
Cartiaux, Benjamin ;
Boucher, Samuel ;
Montel, Charles ;
Gros-Dagnac, Helene ;
Fave, Yoann ;
Peran, Patrice ;
Mogicato, Giovanni ;
Deviers, Alexandra .
FRONTIERS IN NEUROANATOMY, 2022, 16
[25]   SUSCEPTIBILITY-ENHANCED 3-TESLA T1-WEIGHTED SPOILED GRADIENT ECHO OF THE MIDBRAIN NUCLEI FOR GUIDANCE OF DEEP BRAIN STIMULATION IMPLANTATION [J].
Young, Geoffrey S. ;
Feng, Feng ;
Shen, Hao ;
Chen, Nan-kuei .
NEUROSURGERY, 2009, 65 (04) :809-815
[26]   Segmented 3D Echo Planar Acquisition for Rapid Susceptibility-Weighted Imaging: Application to Microhemorrhage Detection in Traumatic Brain Injury [J].
Wang, Wen-Tung ;
Li, Ningzhi ;
Papageorgiou, Ioannis ;
Chan, Leighton ;
Pham, Dzung L. ;
Butman, John A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (05) :1529-1535
[27]   Automated segmentation of deep brain nuclei using convolutional neural networks and susceptibility weighted imaging [J].
Beliveau, Vincent ;
Norgaard, Martin ;
Birkl, Christoph ;
Seppi, Klaus ;
Scherfler, Christoph .
HUMAN BRAIN MAPPING, 2021, 42 (15) :4809-4822
[28]   MR Venography of the Brain With Enhanced Vessel Contrast Using Image-Domain High-Pass Filtering of the Susceptibility Phase Shift [J].
Jin, Zhaoyang ;
Xia, Ling ;
Lou, Min ;
Zhang, Minming ;
Du, Yiping P. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (05) :1218-1225
[29]   Post-embolisation susceptibility changes in giant meningiomas: multiparametric histogram analysis using non-contrast-enhanced susceptibility-weighted PRESTO, diffusion-weighted and perfusion-weighted imaging [J].
Nishiguchi, Tomokazu ;
Iwakiri, Takeshi ;
Hayasaki, Kohji ;
Ohsawa, Masahiko ;
Yoneda, Tetuya ;
Mitsuhashi, Yutaka ;
Nishio, Akimasa ;
Dousset, Vincent ;
Miki, Yukio .
EUROPEAN RADIOLOGY, 2013, 23 (02) :551-561
[30]   Post-embolisation susceptibility changes in giant meningiomas: multiparametric histogram analysis using non-contrast-enhanced susceptibility-weighted PRESTO, diffusion-weighted and perfusion-weighted imaging [J].
Tomokazu Nishiguchi ;
Takeshi Iwakiri ;
Kohji Hayasaki ;
Masahiko Ohsawa ;
Tetuya Yoneda ;
Yutaka Mitsuhashi ;
Akimasa Nishio ;
Vincent Dousset ;
Yukio Miki .
European Radiology, 2013, 23 :551-561