Development and Characterization of a Round Hand-Held Silicon Photomultiplier Based Gamma Camera for Intraoperative Imaging

被引:12
作者
Popovic, Kosta [1 ]
McKisson, Jack E. [2 ]
Kross, Brian [2 ]
Lee, Seungjoon [2 ]
McKisson, John [2 ]
Weisenberger, Andrew G. [2 ]
Proffitt, James [3 ]
Stolin, Alexander [4 ]
Majewski, Stan [4 ]
Williams, Mark B. [5 ,6 ]
机构
[1] Univ Virginia, Dept Phys, Charlottesville, VA 22908 USA
[2] Thomas Jefferson Natl Accelerator Facil, Radiat Detector & Imaging Grp, Newport News, VA 23606 USA
[3] AiT Instruments, Newport News, VA 23606 USA
[4] W Virginia Univ, Ctr Adv Res, Morgantown, WV 23506 USA
[5] Univ Virginia, Dept Phys, Dept Radiol & Med Imaging, Charlottesville, VA 22908 USA
[6] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
关键词
Biomedical imaging; gamma-ray detectors; instrumentation and measurement; SENTINEL LYMPH-NODES; RADIO-GUIDED SURGERY; HIGH-RESOLUTION; LOCALIZATION; PERFORMANCE; BIOPSY;
D O I
10.1109/TNS.2014.2308284
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the development of a hand-held gamma camera for intraoperative surgical guidance that is based on silicon photomultiplier (SiPM) technology. The camera incorporates a cerium doped lanthanum bromide (LaBr3 : Ce) plate scintillator, an array of 80 SiPM photodetectors and a two-layer parallel-hole collimator. The field of view is circular with a 60 mm diameter. The disk-shaped camera housing is 75 mm in diameter, approximately 40.5 mm thick and has a mass of only 1.4 kg, permitting either hand-held or arm-mounted use. All camera components are integrated on a mobile cart that allows easy transport. The camera was developed for use in surgical procedures, including determination of the location and extent of primary carcinomas, detection of secondary lesions, and sentinel lymph node biopsy (SLNB). Here, we describe the camera design and its principal operating characteristics, including spatial resolution, energy resolution, sensitivity uniformity, and geometric linearity. The gamma camera has an intrinsic spatial resolution of 4.2 mm FWHM, an energy resolution of 21.1% FWHM at 140 keV, and a sensitivity of 481 and 73 cps/MBq when using the single-and double-layer collimators, respectively.
引用
收藏
页码:1084 / 1091
页数:8
相关论文
共 27 条
[1]   Intraoperative gamma imaging of axillary sentinel lymph nodes in breast cancer patients [J].
Aarsvod, John N. ;
Greene, Carmen M. ;
Mintzer, Robert A. ;
Grant, Sandra F. ;
Styblo, Toncred M. ;
Alazraki, Naomi P. ;
Patt, Bradley E. ;
Caravaglia, Gina M. ;
Li, Joshua ;
Iwanczyk, Jan S. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2006, 21 :76-79
[2]  
American Association of Physicists in Medicine, 1982, 9 AAPM
[3]  
Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
[4]  
[Anonymous], 12007 NEMA NU
[5]   Intraoperative Imaging Guidance for Sentinel Node Biopsy in Melanoma Using a Mobile Gamma Camera [J].
Dengel, Lynn T. ;
More, Mitali J. ;
Judy, Patricia G. ;
Petroni, Gina R. ;
Smolkin, Mark E. ;
Rehm, Patrice K. ;
Majewski, Stan ;
Williams, Mark B. ;
Slingluff, Craig L., Jr. .
ANNALS OF SURGERY, 2011, 253 (04) :774-778
[6]  
Digirad Corporation, 2007, 2020TC IM FLEX SINGL
[7]  
Garbay J., 2009, CANC RES S, V69, P1021
[8]   Assessment of the solid-state gamma camera to depict axillary sentinel lymph nodes in breast cancer patients [J].
Goto, M ;
Okuyama, C ;
Kubota, T ;
Ushijima, Y ;
Nishimura, T .
ANNALS OF NUCLEAR MEDICINE, 2005, 19 (07) :627-631
[9]  
Judge J, 2012, J NUCL MED, V53
[10]   The Usefulness of a Preoperative Compact Imager, a Hand-Held γ-Camera for Breast Cancer Sentinel Node Biopsy: Final Results of a Prospective Double-Blind, Clinical Study [J].
Kerrou, Khaldoun ;
Pitre, Stephanie ;
Coutant, Charles ;
Rouzier, Roman ;
Ancel, Pierre-Yves ;
Lebeaux, Cecile ;
Huchet, Virginie ;
Montravers, Francoise ;
Pascal, Odile ;
Marie-Alix-Duval ;
Lefebvre, FrancOise ;
Menard, Laurent ;
Uzan, Serge ;
Charon, Yves ;
Barranger, Emmanuel .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (09) :1346-1353