Cooperative Control of SFCL and SMES for Enhancing Fault Ride Through Capability and Smoothing Power Fluctuation of DFIG Wind Farm

被引:80
作者
Ngamroo, Issarachai [1 ]
Karaipoom, Tanapon [1 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Sch Elect Engn, Bangkok 10520, Thailand
关键词
Doubly fed induction generator (DFIG) wind turbine; optimization; superconducting fault current limiter (SFCL); superconducting magnetic energy storage (SMES);
D O I
10.1109/TASC.2014.2340445
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with a cooperative control of a resistive type superconducting fault current limiter (SFCL) and a superconducting magnetic energy storage (SMES) for enhancing fault ride through (FRT) capability and smoothing power fluctuation of the doubly fed induction generator (DFIG)-based wind farm. When the system faults occur, the SFCL is used to limit the fault current, alleviate the terminal voltage drop, and transient power fluctuation so that the DFIG can ride through the fault. Subsequently, the remaining power fluctuation is suppressed by the SMES. The resistive value of the SFCL as well as the superconducting coil inductance of the SMES are simultaneously optimized so that a sudden increase in the kinetic energy in the DFIG rotor during faults, an initial stored energy in the SMES coil, an energy loss of the SFCL, and an output power fluctuation of the DFIG are minimum. The superior control effect of the cooperative SFCL and SMES over the individual device is confirmed by simulation study.
引用
收藏
页数:4
相关论文
共 12 条
[1]  
Abad G., 2011, DOUBLY FED INDUCTION, V85
[2]  
[Anonymous], POWER SYSTEM STABILI
[3]  
[Anonymous], MATLAB SIMPOWERSYSTE
[4]  
[Anonymous], 1995, 1995 IEEE INT C
[5]   Improving Fault Ride-Through Capability of DFIG-Based Wind Turbine Using Superconducting Fault Current Limiter [J].
Elshiekh, Mariam E. ;
Mansour, Diaa-Eldin A. ;
Azmy, Ahmed M. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
[6]   Enhancing Low-Voltage Ride-Through Capability and Smoothing Output Power of DFIG With a Superconducting Fault-Current Limiter-Magnetic Energy Storage System [J].
Guo, Wenyong ;
Xiao, Liye ;
Dai, Shaotao .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) :277-295
[7]   Optimal location assignment and design of superconducting fault current limiters applied to loop power systems [J].
Hongesombut, K ;
Mitani, Y ;
Tsuji, K .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :1828-1831
[8]   Application of SMES and Grid Code Compliance to Wind/Photovoltaic Generation System [J].
Kim, Seung-Tak ;
Kang, Byung-Kwan ;
Bae, Sun-Ho ;
Park, Jung-Wook .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
[9]   The Effect of SFCL on Electric Power Grid With Wind-Turbine Generation System [J].
Park, Woo-Jae ;
Sung, Byung Chul ;
Park, Jung-Wook .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) :1177-1181
[10]  
Schlabbach J., 2008, PROC 5 INT C EUR ELE, P1