Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring

被引:9
作者
Zhu, Yusi [1 ,2 ]
Xia, Pan [1 ,2 ]
Liu, Jihang [1 ,2 ]
Fang, Zhen [1 ,2 ,3 ]
Du, Lidong [1 ,2 ]
Zhao, Zhan [1 ,2 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] Chinese Acad Med Sci, Personalized Management Chron Resp Dis, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
film bulk acoustic resonator (FBAR); humidity sensor; dual-parameter detecting; polyimide (PI); respiration monitoring; HIGH-SENSITIVITY; GRAPHENE OXIDE; WIDE-RANGE; WAVE;
D O I
10.3390/mi13050758
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Respiration monitoring is vital for human health assessment. Humidity sensing is a promising way to establish a relationship between human respiration and electrical signal. This paper presents a polyimide-based film bulk acoustic resonator (PI-FBAR) humidity sensor operating in resonant frequency and reflection coefficient S-11 dual-parameter with high sensitivity and stability, and it is applied in real-time human respiration monitoring for the first time. Both these two parameters can be used to sense different breathing conditions, such as normal breathing and deep breathing, and breathing with different rates such as normal breathing, slow breathing, apnea, and fast breathing. Experimental results also indicate that the proposed humidity sensor has potential applications in predicting the fitness of individual and in the medical field for detecting body fluids loss and daily water intake warning. The respiratory rates measured by our proposed PI-FBAR humidity sensor operating in frequency mode and S-11 mode have Pearson correlation of up to 0.975 and 0.982 with that measured by the clinical monitor, respectively. Bland-Altman method analysis results further revealed that both S-11 and frequency response are in good agreement with clinical monitor. The proposed sensor combines the advantages of non-invasiveness, high sensitivity and high stability, and it has great potential in human health monitoring.
引用
收藏
页数:16
相关论文
共 37 条
[1]   Chemically Sensitized Thin-Film Bulk Acoustic Wave Resonators as Humidity Sensors [J].
Ashley, G. M. ;
Kirby, P. B. ;
Butler, T. P. ;
Whatmore, R. ;
Luo, J. K. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2010, 157 (12) :J419-J424
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Polyimide-Based Capacitive Humidity Sensor [J].
Boudaden, Jamila ;
Steinmassl, Matthias ;
Endres, Hanns-Erik ;
Drost, Andreas ;
Eisele, Ignaz ;
Kutter, Christoph ;
Mueller-Buschbaum, Peter .
SENSORS, 2018, 18 (05)
[4]   Dual-mode resonant infrared detector based on film bulk acoustic resonator toward ultra-high sensitivity and anti-interference capability [J].
Chen, Cong ;
Shang, Zhengguo ;
Zhang, Feng ;
Zhou, Hong ;
Yang, Jing ;
Wang, Dengpan ;
Chen, Yu ;
Mu, Xiaojing .
APPLIED PHYSICS LETTERS, 2018, 112 (24)
[5]   Noncontact Heartbeat and Respiration Monitoring Based on a Hollow Microstructured Self-Powered Pressure Sensor [J].
Chen, Shuwen ;
Wu, Nan ;
Ma, Long ;
Lin, Shizhe ;
Yuan, Fang ;
Xu, Zisheng ;
Li, Wenbo ;
Wang, Bo ;
Zhou, Jun .
ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (04) :3660-3667
[6]   Wide range high speed relative humidity sensor based on PEDOT:PSS-PVA composite on an IDT printed on piezoelectric substrate [J].
Choi, Kyung Hyun ;
Sajid, Memoon ;
Aziz, Shahid ;
Yang, Bong-Su .
SENSORS AND ACTUATORS A-PHYSICAL, 2015, 228 :40-49
[7]   Cu(OH)2 nanowires/graphene oxide composites based QCM humidity sensor with fast-response for real-time respiration monitoring [J].
Fang, Han ;
Lin, Jianbin ;
Hu, Zhixiang ;
Liu, Huan ;
Tang, Zirong ;
Shi, Tielin ;
Liao, Guanglan .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304
[8]   Paper-Based Electrical Respiration Sensor [J].
Gueder, Firat ;
Ainla, Alar ;
Redston, Julia ;
Mosadegh, Bobak ;
Glavan, Ana ;
Martin, T. J. ;
Whitesides, George M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (19) :5727-5732
[9]   Simple high-sensitivity optical fiber humidity sensor [J].
Guo, Jiachen ;
Chang, Min ;
Xiao, Yinfeng ;
Song, Qiuheng ;
Zhao, Dong ;
Jia, Bo .
APPLIED OPTICS, 2021, 60 (21) :5990-5994
[10]  
Harper B.D., 1994, J ELECT PACKAG, V116, P317, DOI [10.1115/1.2905704, DOI 10.1115/1.2905704]