Experimental study of a membrane-based liquid desiccant dehumidifier based on internal air temperature variation

被引:13
作者
Chu, Junze [1 ]
Zhu, Jie [1 ]
Bai, Hongyu [1 ]
Cui, Yuanlong [2 ]
机构
[1] Univ Nottingham, Dept Archirerture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Built Environm, Coll Engn & Technol, Derby DE22 3AW, England
关键词
Membrane based liquid desiccant dehumidifier; Temperature field; Performance evaluation; Experimental study; ENERGY EXCHANGER LAMEE; MASS-TRANSFER; PERFORMANCE ANALYSIS; FLUID-FLOW; MODEL; HEAT; SIMULATION; SYSTEMS; SINGLE;
D O I
10.1016/j.applthermaleng.2019.113936
中图分类号
O414.1 [热力学];
学科分类号
摘要
A membrane-based liquid desiccant dehumidifier with the separated air stream and liquid desiccant channels has the ability to solve its working fluid carryover problem in the traditional direct contact system. The sensible, latent, total effectiveness and air moisture removal rate are adopted for the dehumidifier performance evaluation in this paper, and the dehumidifier main operating parameters are investigated experimentally to identify their influences and internal air temperature variations, including inlet air relative humidity (RH), inlet solution concentration and temperature, heat capacity rate ratio (Cr*) and number of heat transfer units (NTU). It is found that both the inlet air RH and solution temperature have the negative influences on the dehumidifier effectiveness, while the desiccant solution concentration has little positive influence; the air moisture removal rate rises sharply with the inlet air RH and solution concentration. The highest sensible, latent and total effectiveness achieved in this study are 0.823, 0.802 and 0.810 respectively when both Cr* and NTU are equal to 12. However the operating condition with NTU = 8 and Cr* = 6 is recommended with the corresponding sensible, latent and total effectiveness of 0.758, 0.71 and 0.728 respectively.
引用
收藏
页数:10
相关论文
共 35 条
[1]   Performance analysis of a membrane liquid desiccant air-conditioning system [J].
Abdel-Salam, Ahmed H. ;
Ge, Gaoming ;
Simonson, Carey J. .
ENERGY AND BUILDINGS, 2013, 62 :559-569
[2]   Sensitivity of the performance of a flat-plate liquid-to-air membrane energy exchanger (LAMEE) to the air and solution channel widths and flow maldistribution [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 84 :1082-1100
[3]   Performance of a solar liquid desiccant air conditioner - An experimental and theoretical approach [J].
Alizadeh, Shahab .
SOLAR ENERGY, 2008, 82 (06) :563-572
[4]  
[Anonymous], 842008 ANSIASHRAE
[5]  
[Anonymous], 2005, ASHRAE Handbook-Fundamentals
[6]   Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Ma, Lina ;
Wang, Ruzhu ;
Li, Tingxian .
APPLIED THERMAL ENGINEERING, 2017, 119 :119-131
[7]   On the performances of a hybrid air-conditioning system in different climatic conditions [J].
Bergero, Stefano ;
Chiari, Anna .
ENERGY, 2011, 36 (08) :5261-5273
[8]   AN ANALYTIC CORRELATION FOR THE VAPOR-PRESSURE OF AQUEOUS AND NONAQUEOUS SOLUTIONS OF SINGLE AND MIXED ELECTROLYTES .2. APPLICATION AND EXTENSION [J].
CISTERNAS, LA ;
LAM, EJ .
FLUID PHASE EQUILIBRIA, 1991, 62 (1-2) :11-27
[9]   Simulation of potential standalone liquid desiccant cooling cycles [J].
Das, Rajat Subhra ;
Jain, Sanjeev .
ENERGY, 2015, 81 :652-661
[10]   Comparison of experimental data and a model for heat and mass transfer performance of a liquid-to-air membrane energy exchanger (LAMEE) when used for air dehumidification and salt solution regeneration [J].
Ge, Gaoming ;
Moghaddam, Davood Ghadiri ;
Abdel-Salam, Ahmed H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 68 :119-131