Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: Comparison with magnetic resonance imaging and radionuclide ventriculography

被引:95
作者
Nesser, H. Joachim
Tkalec, Wolfgang
Patel, Ayan R.
Masani, Navroz D.
Niel, J.
Markt, Bernhard
Pandian, Natesa G.
机构
[1] Publ Hosp Elisabethinen, Dept Cardiol, Linz, Austria
[2] Tufts Univ New England Med Ctr, Cardiovasc Imaging & Hemodynam Lab, Boston, MA USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2006年 / 23卷 / 08期
关键词
three-dimensional echocardiography; right ventricular volumes; magnetic resonance imaging; radionuclide ventriculography;
D O I
10.1111/j.1540-8175.2006.00286.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional echocardiography (3DE) provides volumetric measurements without geometric assumptions. Volume-rendered 3DE has been shown to be accurate for the measurement of right ventricular (RV) volumes in vitro and in animal studies; however, few data are available regarding its accuracy in patients. This study examined the accuracy of 3DE for quantitation of RV volumes and ejection fraction (EF) in patients, compared to magnetic resonance imaging (MRI) and radionuclide ventriculography (RNV). Twenty patients underwent MRI, gated equilibrium RNV, and 3DE using rotational acquisition from both the transesophageal and transthoracic approaches. RV volumes and EF were calculated from the 3DE data using multislice analysis (true Simpson's rule). RV volumes calculated by MRI (end-diastolic volume (EDV) 109.4 +/- 34.3 mls, end-systolic volume (ESV) 59.6 +/- 31.0 mls, and EF 47.7 +/- 17.1%) agreed closely with 3DE. For transesophageal echocardiography, EDV was 108.1 +/- 29.7 mls (r = 0.86, mean difference 1.3 +/- 17.8 mls); ESV was 62.5 +/- 23.8 mls (r = 0.85, mean difference 2.8 +/- 15.1 mls); and EF was 43.2 +/- 11.7% (r = 0.84, mean difference 4.5 +/- 9.7%). For transthoracic echocardiography, EDV was 107.7 +/- 27.5mls (r = 0.85, mean difference 1.6 +/- 18.2mls); ESV was 59.7 +/- 22.1 mls (r = 0.93, mean difference 3.2 +/- 19.6 mls); and EF was 45.2 +/- 11.5% (r = 0.86, mean difference 2.0 +/- 9.4%). There were close correlations, small mean differences and narrow limits of agreement between RNV-derived EF (43.4 +/- 12.1%) and both transesophageal (r = 0.95 mean difference 0.2 +/- 3.7%) and transthoracic 3DE (r = 0.95, mean difference 1.8 +/- 5.4%). Three-dimensional echocardiography is a promising new method of calculating RV volumes and EF, comparing well with MRI and RNV. The accuracy of transthoracic 3DE was comparable to that of the transesophageal approach. Three-dimensional echocardiography has the potential to be useful in the clinical assessment of RV disorders.
引用
收藏
页码:666 / 680
页数:15
相关论文
共 49 条
[1]  
Aebischer N M, 1989, J Am Soc Echocardiogr, V2, P110
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   DETERMINATION OF RIGHT ATRIAL AND RIGHT VENTRICULAR SIZE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
BOMMER, W ;
WEINERT, L ;
NEUMANN, A ;
NEEF, J ;
MASON, DT ;
DEMARIA, A .
CIRCULATION, 1979, 60 (01) :91-100
[4]   DIRECT QUANTITATION OF RIGHT AND LEFT-VENTRICULAR VOLUMES WITH NUCLEAR-MAGNETIC-RESONANCE IMAGING IN PATIENTS WITH PRIMARY PULMONARY-HYPERTENSION [J].
BOXT, LM ;
KATZ, J ;
KOLB, T ;
CZEGLEDY, FP ;
BARST, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1508-1515
[5]   RIGHT VENTRICULAR INFARCTION - CLINICAL AND HEMODYNAMIC FEATURES [J].
COHN, JN ;
GUIHA, NH ;
BRODER, MI ;
LIMAS, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (02) :209-214
[6]  
CULHAM JAG, 1988, J CAN ASSOC RADIOL, V39, P247
[7]   Intraoperative assessment of right ventricular volume and function [J].
De Simone, R ;
Wolf, I ;
Mottl-Link, S ;
Böttiger, BW ;
Rauch, H ;
Meinzer, HP ;
Hagl, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (06) :988-993
[8]   NON-GEOMETRIC DETERMINATION OF RIGHT VENTRICULAR VOLUMES FROM EQUILIBRIUM BLOOD POOL SCANS [J].
DEHMER, GJ ;
FIRTH, BG ;
HILLIS, LD ;
NICOD, P ;
WILLERSON, JT ;
LEWIS, SE .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (01) :78-84
[9]   VALIDATION OF ATTENUATION-CORRECTED EQUILIBRIUM RADIONUCLIDE ANGIOGRAPHIC DETERMINATIONS OF RIGHT VENTRICULAR VOLUME - COMPARISON WITH CAST-VALIDATED BIPLANE CINEVENTRICULOGRAPHY [J].
DELLITALIA, LJ ;
STARLING, MR ;
WALSH, RA ;
BADKE, FR ;
LASHER, JC ;
BLUMHARDT, R .
CIRCULATION, 1985, 72 (02) :317-326
[10]   Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography - A validation study using magnetic resonance imaging [J].
Fujimoto, S ;
Mizuno, R ;
Nakagawa, Y ;
Dohi, K ;
Nakano, H .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (06) :385-390