Measurement of pulmonary blood flow by fractal analysis of flow heterogeneity in isolated canine lungs

被引:22
作者
Barman, SA [1 ]
McCloud, LL [1 ]
Catravas, JD [1 ]
Ehrhart, IC [1 ]
机构
[1] MED COLL GEORGIA,DEPT PHYSIOL & ENDOCRINOL,VASC BIOL CTR,AUGUSTA,GA 30912
关键词
pulmonary blood flow distribution; microspheres; relative dispersion; vascular recruitment; pulmonary vascular resistance; fractal analysis;
D O I
10.1152/jappl.1996.81.5.2039
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Regional heterogeneity of lung blood flow can be measured by analyzing the relative dispersion (RD) of mass (weight)-flow data. Numerous studies have shown that pulmonary blood flow is fractal in nature, a phenomenon that can be characterized by the fractal dimension and the RD for the smallest realizable volume element (piece size). Although information exists for the applicability of fractal analysis to pulmonary blood flow in whole animal models, little is known in isolated organs. Therefore, the present study was done to determine the effect of blood flow rate on the distribution of pulmonary blood flow in the isolated blood-perfused canine lung lobe by using fractal analysis. Four different radiolabeled microspheres (Ce-141, Nb-95, Sr-85, and Cr-51), each 15 mu m in diameter, were injected into the pulmonary lobar artery of isolated canine lung lobes (n = 5) perfused at four different flow rates (flow 1 = 0.42 +/- 0.02 l/min; flow 2 = 1.12 +/- 0.07 l/min; flow 3 = 2.25 +/- 0.17 l/min; flow 4 = 2.59 +/- 0.17 l/min), and the pulmonary blood flow distribution was measured. The results of the present study indicate that under isogravimetric blood flow conditions, all regions of horizontally perfused isolated lung lobes received blood flow that was preferentially distributed to the most distal caudal regions of the lobe. Regional pulmonary blood flow in the isolated perfused canine lobe was heterogeneous and fractal in nature, as measured by the RD. As flow rates increased, fractal dimension values (averaging 1.22 +/- 0.08) remained constant, whereas RD decreased, reflecting more homogeneous blood flow distribution. At any given blood flow rate, high-flow areas of the lobe received a proportionally larger amount of regional flow, suggesting that the degree of pulmonary vascular recruitment may also be spatially related.
引用
收藏
页码:2039 / 2045
页数:7
相关论文
共 34 条
[1]   MEASUREMENT OF REGIONAL BRONCHIAL ARTERIAL BLOOD-FLOW AND BRONCHOVASCULAR RESISTANCE IN DOGS [J].
BAILE, EM ;
NELEMS, JMB ;
SCHULZER, M ;
PARE, PD .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (04) :1044-1049
[2]   PULMONARY AND SYSTEMIC BLOOD-FLOW CONTRIBUTIONS TO UPPER AIRWAYS IN CANINE LUNG [J].
BARMAN, SA ;
ARDELL, JL ;
PARKER, JC ;
PERRY, ML ;
TAYLOR, AE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (05) :H1130-H1135
[3]   FRACTAL MODELING OF BIOLOGICAL STRUCTURES [J].
BARNSLEY, MF ;
MASSOPUST, P ;
STRICKLAND, H ;
SLOAN, AD .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 504 :179-194
[4]  
BASSINGTHWAIGHTE JB, 1988, NEWS PHYSIOL SCI, V3, P5
[5]   FRACTAL NATURE OF REGIONAL MYOCARDIAL BLOOD-FLOW HETEROGENEITY [J].
BASSINGTHWAIGHTE, JB ;
KING, RB ;
ROGER, SA .
CIRCULATION RESEARCH, 1989, 65 (03) :578-590
[6]   DIFFERENCES IN REGIONAL VASCULAR CONDUCTANCES IN ISOLATED DOG LUNGS [J].
BECK, KC ;
REHDER, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) :530-538
[7]   REGIONAL TRAPPING OF MICROSPHERES IN THE LUNG COMPARES WELL WITH REGIONAL BLOOD-FLOW [J].
BECK, KC .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (02) :883-889
[8]   INFLUENCE OF VASCULAR DISTENDING PRESSURE ON REGIONAL FLOWS IN ISOLATED PERFUSED DOG LUNGS [J].
BECK, KC .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (05) :1869-1874
[9]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[10]   EFFECTS OF PULMONARY BLOOD-FLOW ON THE FRACTAL NATURE OF FLOW HETEROGENEITY IN SHEEP LUNGS [J].
CARUTHERS, SD ;
HARRIS, TR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (03) :1474-1479