Mouse aversion to isoflurane versus carbon dioxide gas

被引:29
作者
Moody, Carly M. [1 ]
Weary, Daniel M. [1 ]
机构
[1] Univ British Columbia, Fac Land & Food Syst, Anim Welf Program, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Euthanasia; Vaporizer; Drop method; Recumbency; Light-dark paradigm; VOLATILE ANESTHETICS; RATS; MICE; EUTHANASIA; BEHAVIOR; INHALATION; EXPOSURE; MODEL;
D O I
10.1016/j.applanim.2014.04.011
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Isoflurane and carbon dioxide (CO2) gas are used for rodent euthanasia. This study compared mouse aversion to isoflurane versus gradual-fill CO2 gas, and compared two methods of isoflurane delivery: vaporizer and drop. Mouse acclimation to a light dark apparatus was used to create a light aversion test based on an unconditioned preference for dark versus light areas. Mice chose between remaining in a dark compartment with rising concentration of one of three treatments (20% gradual-fill chamber vol/min of CO2, n = 8; 5% isoflurane administered using a vaporizer set at 4 L/min oxygen flow, n = 9; or 5% liquid isoflurane dropped on gauze, n = 9), or escaping to a brightly lit compartment. On average (+/- S.E.) mice left the dark compartment after 29.2 +/- 6.1 s in the isoflurane vaporizer treatment. Initial withdrawal time was lower for the CO2 treatment (P = 0.04), averaging 16.6 +/- 2.8 s, and lower still for the isoflurane drop treatment (P < 0.001), averaging 2.9 +/- 0.79 s. Five of nine mice became recumbent in the dark compartment when exposed to the isoflurane vaporizer treatment compared to only two of nine mice during the drop treatment (P = 0.3) and zero of eight mice during the CO2 treatment (P = 0.03). The isoflurane concentrations rose more quickly using the drop versus the vaporizer method, likely explaining the increased willingness of mice to be exposed to isoflurane administered via a vaporizer machine. Re-exposure to isoflurane with the vaporizer was more aversive than initial exposure; only two of nine mice stayed in the dark compartment until recumbency. These results support the recommendation that mice with no previous exposure to isoflurane should be euthanised using isoflurane administered by a vaporizer rather than CO2 gas, and suggest that the drop method (as applied in the current study) is not a suitable alternative. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 24 条
[1]  
American Veterinary Medical Association, 2013, GUID EUTH AN 2013
[2]  
Canadian Council on Animal Care, 2010, ADD INF EFF EUTH MET
[3]   Changes in mucociliary activity may be used to investigate the airway-irritating potency of volatile anaesthetics [J].
Cervin, A ;
Lindberg, S .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (04) :475-480
[4]   CARBON-DIOXIDE INHALATION, STRESS AND ANXIOGENIC DRUGS REDUCE THE FUNCTION OF GABA(A) RECEPTOR COMPLEX IN THE RAT-BRAIN [J].
CONCAS, A ;
SANNA, E ;
CUCCHEDDU, T ;
MASCIA, MP ;
SANTORO, G ;
MACIOCCO, E ;
BIGGIO, G .
PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 1993, 17 (04) :651-661
[5]   EXPLORATION OF MICE IN A BLACK AND WHITE TEST BOX - VALIDATION AS A MODEL OF ANXIETY [J].
COSTALL, B ;
JONES, BJ ;
KELLY, ME ;
NAYLOR, RJ ;
TOMKINS, DM .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1989, 32 (03) :777-785
[6]   PRELIMINARY-REPORT OF A SIMPLE ANIMAL BEHAVIOR MODEL FOR THE ANXIOLYTIC EFFECTS OF BENZODIAZEPINES [J].
CRAWLEY, J ;
GOODWIN, FK .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1980, 13 (02) :167-170
[7]  
DOI M, 1993, CAN J ANAESTH, V40, P122, DOI 10.1007/BF03011308
[8]  
Flecknell P., 2009, LAB ANIMAL ANAESTHES, P54
[9]   A new approach to the light/dark test procedure in mice [J].
Hascoët, M ;
Bourin, M .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1998, 60 (03) :645-653
[10]   The validity of using an approach-avoidance test to measure the strength of aversion to carbon dioxide in rats [J].
Kirkden, Richard D. ;
Niel, Lee ;
Lee, Gary ;
Makowska, I. Joanna ;
Pfaffinger, Marianne J. ;
Weary, Daniel M. .
APPLIED ANIMAL BEHAVIOUR SCIENCE, 2008, 114 (1-2) :216-234