Improved magnetization preparation for navigator steady-state free precession 3D coronary MR angiography

被引:9
|
作者
Nguyen, TD [1 ]
Spincemaille, P [1 ]
Wang, Y [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, MR Res Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
关键词
magnetic resonance angiography; coronary arteries; steady state free precession; trueFISP; navigator echo;
D O I
10.1002/mrm.20095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to investigate a new magnetization preparation scheme for navigator steady-state free precession (SSFP) 3D coronary MR angiography (MRA) that executes the navigator and fat saturation pulses in steady state after the dummy RFs in order to minimize the delay between the magnetization preparation and the image echoes. Compared to the previous preparation scheme that executes the navigator and fat saturation pulses before the dummy RFs, the new scheme was found to provide more effective motion suppression, significantly improved blood-to-myocardium contrast-to-noise ratio (46%, P < 0.001) at slightly but insignificantly decreased blood signal-to-noise ratio (SNR) (2%, P = 0.73), significantly reduced fat SNR (32%, P < 0.001), and better overall image quality (P = 0.05; Wilcoxon paired sample signed rank test). (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1297 / 1300
页数:4
相关论文
共 50 条
  • [1] Cardiac fat navigator-gated steady-state free precession 3D magnetic resonance angiography of coronary arteries
    Nguyen, Thanh D.
    Spincemaille, Pascal
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 210 - 215
  • [2] MR angiography using steady-state free precession
    Foo, TKF
    Ho, VB
    Marcos, HB
    Hood, MN
    Choyke, PL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 699 - 706
  • [3] Evaluation of balanced steady-state free precession (TrueFISP) and K-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla
    Kaul, MG
    Stork, A
    Bansmann, PM
    Nolte-Ernsting, C
    Lund, GK
    Weber, C
    Adam, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (11): : 1560 - 1565
  • [4] Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries
    Barkhausen, J
    Hunold, P
    Jochims, M
    Eggebrecht, H
    Sabin, GV
    Erbel, R
    Debatin, JF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 725 - 730
  • [5] Flow Targeted 3D Steady-State Free-Precession Coronary MR Angiography Comparison of Three Different Imaging Approaches
    Katoh, Marcus
    Spuentrup, Elmar
    Stuber, Matthias
    Buecker, Arno
    Manning, Warren J.
    Guenther, Rolf W.
    Botnar, Rene M.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (12) : 757 - 762
  • [6] 3D non-contrast-enhanced MR angiography with balanced steady-state free precession Dixon method
    Stafford, Randall B.
    Sabati, Mohammad
    Mahallati, Houman
    Frayne, Richard
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 430 - 433
  • [7] Renal Transplant: Nonenhanced Renal MR Angiography with Magnetization-prepared Steady-State Free Precession
    Liu, Xin
    Berg, Natasha
    Sheehan, John
    Bi, Xiaoming
    Weale, Peter
    Jerecic, Renate
    Carr, James
    RADIOLOGY, 2009, 251 (02) : 535 - 542
  • [8] Phase preparation in steady-state free precession MR elastography
    Rump, Jens
    Warmuth, Carsten
    Braun, Jurgen
    Sack, Ingolf
    MAGNETIC RESONANCE IMAGING, 2008, 26 (02) : 228 - 235
  • [9] 2128 Free-breathing steady-state free precession 3D coronary MRA: comparison of diaphragm and cardiac fat navigator techniques
    Thanh D Nguyen
    Pascal Spincemaille
    Martin R Prince
    Yi Wang
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [10] Navigator-gated three-dimensional MR angiography of the pulmonary arteries using steady-state free precession
    Hui, BK
    Noga, ML
    Gan, KD
    Wilman, AH
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) : 831 - 835