Development of a fluorescence polarization immunoassay for lorazepam quantification

被引:6
|
作者
Agbuya, PG
Li, L
Miles, MV
Zaritsky, AL
Morris, AD
机构
[1] EASTERN VIRGINIA MED SCH,CTR PEDIAT RES,NORFOLK,VA 23510
[2] CHILDRENS HOSP KINGS DAUGHTERS,DEPT PEDIAT,DIV CRIT CARE MED,NORFOLK,VA
[3] OLD DOMINION UNIV,DEPT CHEM & BIOCHEM,NORFOLK,VA
关键词
lorazepam; benzodiazepine; fluorescence polarization immunoassay; analysis;
D O I
10.1097/00007691-199604000-00014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Lorazepam concentrations have been quantified in biological fluids using gas chromatography and high-performance liquid chromatography (HPLC). However, these methods are too time consuming and labor intensive for most nonresearch laboratories to offer. A fluorescence polarization immunoassay (FPIA) method for quantification of lorazepam was developed and validated using a reverse-phase HPLC method as the reference method. The FPIA method involves a single liquid-liquid extraction of 100 mu l of either serum or plasma, then direct analysis using the TDxFLx (Abbott Diagnostics, North Chicago, IL). FPIA calibrations were linear between 50 and 800 ng/ml using five calibrators prepared in human serum. Within-run precision (n = 10) for three serum controls (75, 300, and 600 ng/ml) resulted in coefficients of variation (CVs) of 5.7%, 5.4%, and 4.2%, respectively. Between-day precision studies for the three serum controls were 7.0%, 8.9% and 4.9%, respectively (n = 5). The analytical recovery of the three serum controls was 104.9%, 97.3% and 98.3%, respectively. There was an excellent linear correlation between the FPIA and HPLC determinations of 43 patient specimens (r = 0.990, slope = 0.961, intercept = 16.3). No interferences were found from many commonly prescribed nonbenzodiazepine drugs; however, other benzodiazepines that were tested will cross-react with this procedure and give inaccurate results. Therefore, this method should not be used in patients who are receiving other benzodiazepines in addition to lorazepam. The FPIA method described herein can be adapted to reliably measure lorazepam concentrations in serum or plasma.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [1] Development of a fluorescence polarization immunoassay for lorazepam quantification.
    Agbuya, PG
    Li, L
    Miles, MV
    Zaritsky, AL
    Morris, AD
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (01) : A60 - A60
  • [2] Development of a Fluorescence Polarization Immunoassay for the Quantification of Tylosin in Honey
    Eremin, S. A.
    Mukhametova, L. I.
    Arutyunyan, D. A.
    Tereshchenkov, A. G.
    Sumbatyan, N. V.
    Priima, A. D.
    Nesterenko, I. S.
    Berlina, A. N.
    Sotnikov, D. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (02) : 154 - 161
  • [3] Development of fluorescence polarization immunoassay
    Zhu, GH
    Zheng, H
    Ju, HX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (01) : 102 - 106
  • [4] Development of a fluorescence polarization immunoassay for sulfamerazine
    College of Veterinary Medicine, China Agricultural University, Beijing 100094, China
    Guang Pu Xue Yu Guang Pu Fen Xi, 2008, 7 (1621-1625):
  • [5] Development of a fluorescence polarization immunoassay for sulfamerazine
    Wang Zhan-hui
    Zhang Su-xia
    Shen Jian-zhong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (07) : 1621 - 1625
  • [6] RAPID QUANTIFICATION OF PENTOBARBITAL IN SERUM BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    LI, PK
    LEE, JT
    SCHREIBER, RM
    CLINICAL CHEMISTRY, 1984, 30 (02) : 307 - 308
  • [7] PENTOBARBITAL QUANTIFICATION IN THE PRESENCE OF PHENOBARBITAL BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    EARL, R
    SOBESKI, L
    TIMKO, D
    MARKIN, R
    CLINICAL CHEMISTRY, 1991, 37 (10) : 1774 - 1777
  • [8] Quantification of Diethyl Phthalate by a Rapid and Homogenous Fluorescence Polarization Immunoassay
    Tian, Xi
    Dong, Yaqing
    Wang, Yufen
    Song, Zhaorui
    Meng, Meng
    Eremin, Sergei A.
    Deng, Chuan
    Yin, Yongmei
    Xi, Rimo
    ANALYTICAL LETTERS, 2015, 48 (18) : 2843 - 2855
  • [9] Development of a fluorescence polarization immunoassay for zonisamide.
    Kaminski, P
    Holt, DW
    Kainth, S
    Chusney, GD
    Asayama, K
    Ohkaru, Y
    Hwang, D
    CLINICAL CHEMISTRY, 2003, 49 (06) : A122 - A122
  • [10] Development of a fluorescence polarization immunoassay for topiramate.
    Cawley, D
    Stenglein, K
    Mueggler, P
    Steury, A
    Doose, DR
    Scott, VV
    Desai, DM
    Walker, SA
    Stubbs, RJ
    CLINICAL CHEMISTRY, 1996, 42 (06) : 486 - 486