CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality

被引:58
作者
Zhang, Wei-lan [1 ]
Li, Min [2 ]
Zhang, Bo [1 ]
Geng, Hai-yang [1 ]
Liang, Yin-qiang [1 ]
Xu, Ke [1 ,3 ]
Li, Song-bai [1 ]
机构
[1] China Med Univ, Affiliated Hosp 1, Dept Radiol, Shenyang, Peoples R China
[2] China Med Univ, Affiliated Hosp 1, Dept Clin Epidemiol, Shenyang, Peoples R China
[3] China Med Univ, Inst Radiol, Shenyang, Peoples R China
关键词
CONTRAST-INDUCED NEPHROPATHY; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; CHEST CT; CORONARY-ANGIOGRAPHY; CURRENT MODULATION; REDUCTION; ENHANCEMENT; ALGORITHM; EXPOSURE;
D O I
10.1371/journal.pone.0081486
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: We aimed to assess the effectiveness and feasibility of head-and-neck Computed Tomography Angiography (CTA) with low tube voltage and low concentration contrast media combined with iterative reconstruction algorithm. Methods: 92 patients were randomly divided into group A and B: patients in group A received a conventional scan with 120 kVp and contrast media of 320 mgI/ml. Patients in group B, 80 kVp and contrast media of 270 mgI/ml were used along with iterative reconstruction algorithm techniques. Image quality, radiation dose and the effectively consumed iodine amount between two groups were analyzed and compared. Results: Image quality of CTA of head-and-neck vessels obtained from patients in group B was significantly improved quantitatively and qualitatively. In addition, CT attenuation values in group B were also significantly higher than that in group A (p<0.001). Furthermore, compared with the protocol whereby 120 kVp and 320 mgI/dl were administrated, the mean radiation dose and consumed iodine amount in protocol B were also reduced by 50% and 15.6%, respectively (p<0.001). Conclusions: With the help of iterative reconstruction algorithm techniques, the head-and-neck CTA with diagnostic quality can be adequately acquired with low tube voltage and low concentration contrast media. This method could be potentially extended to include any part of the body to reduce the risks related to ionizing radiation.
引用
收藏
页数:7
相关论文
共 39 条
[1]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[2]   Contrast optimization and scan timing for single and multidetector-row computed tomography [J].
Brink, JA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 :S3-S8
[3]   Effects of Iopamidol-370 Versus Iodixanol-320 on Coronary Contrast, Branch Depiction, and Heart Rate Variability in Dual-Source Coronary MDCT Angiography [J].
Christensen, Jared D. ;
Meyer, Laura T. ;
Hurwitz, Lynne M. ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :W445-W451
[4]   Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[5]   80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL) [J].
Faggioni, Lorenzo ;
Neri, Emanuele ;
Sbragia, Paola ;
Pascale, Rachele ;
D'Errico, Luigia ;
Caramella, Davide ;
Bartolozzi, Carlo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) :1220-1225
[6]   Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas [J].
Fenchel, S ;
Fleiter, TR ;
Aschoff, AJ ;
van Gessel, R ;
Brambs, HJ ;
Merkle, EM .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922) :821-830
[7]   Mortality associated with nephropathy after radiographic contrast exposure [J].
From, Aaron M. ;
Bartholmai, Brian J. ;
Williams, Amy W. ;
Cha, Stephen S. ;
Mcdonald, Furman S. .
MAYO CLINIC PROCEEDINGS, 2008, 83 (10) :1095-1100
[8]   Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study [J].
Funama, Y ;
Awai, K ;
Nakayama, Y ;
Kakei, K ;
Nagasue, N ;
Shimamura, M ;
Sato, N ;
Sultana, S ;
Morishita, S ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :905-910
[9]   The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency [J].
Gruberg, L ;
Mintz, GS ;
Mehran, R ;
Dangas, G ;
Lansky, AJ ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (05) :1542-1548
[10]   Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation [J].
Herzog, Christopher ;
Mulvihill, Denise M. ;
Nguyen, Shaun A. ;
Savino, Giancarlo ;
Schmidt, Bernhard ;
Costello, Philip ;
Vogl, Thomas J. ;
Schoepf, U. Joseph .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) :1232-1240