Label free, electric field mediated ultrasensitive electrochemical point-of-care device for CEA detection

被引:20
作者
Chakraborty, B. [1 ]
Das, A. [1 ]
Mandal, N. [2 ]
Samanta, N. [3 ]
Das, N. [4 ]
Chaudhuri, C. Roy [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Elect & Telecommun Engn, Sibpur 711103, W Bengal, India
[2] Indian Inst Technol Goa, Sch Elect Sci, Ponda 403401, Goa, India
[3] Techno India Univ, Dept Elect & Commun Engn, Sect 5, Kolkata 700091, W Bengal, India
[4] KL Univ, Dept Elect & Commun Engn, Vaddeswaram 522502, Andhra Pradesh, India
关键词
REDUCED GRAPHENE OXIDE; CARCINOEMBRYONIC ANTIGEN; SENSOR; NANOCOMPOSITES; AMPLIFICATION; COMPOSITES; APTASENSOR; BIOSENSOR; GLUCOSE; CANCER;
D O I
10.1038/s41598-021-82580-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Developing point-of-care (PoC) diagnostic platforms for carcinoembryonic antigen detection is essential. However, thefew implementations of transferring the signal amplification strategies in electrochemical sensing on paper-based platforms are not satisfactory in terms of detection limit (LOD). In the quest for pushing down LOD, majority of the research has been targeted towards development of improved nanostructured substrates for entrapping more analyte molecules and augmenting the electron transfer rate to the working electrode. But, such approaches have reached saturation. This paper focuses on enhancing the mass transport of the analyte towards the sensor surface through the application of an electric field, in graphene-ZnO nanorods heterostructure. These hybrid nanostructures have been deposited on flexible polyethylene terephthalate substrates with screen printed electrodes for PoC application. The ZnO nanorods have been functionalized with aptamers and the working sensor has been integrated with smartphone interfaced indigenously developed low cost potentiostat. The performance of the system, requiring only 50 mu l analyte has been evaluated using electrochemical impedance spectroscopy and validated against commercially available ELISA kit. Limit of detection of 1 fg/ml in human serum with 6.5% coefficient of variation has been demonstrated, which is more than three orders of magnitude lower than the existing attempts on PoC device.
引用
收藏
页数:12
相关论文
共 38 条
  • [1] Trimetallic Pd@Au@Pt nanocomposites platform on -COOH terminated reduced graphene oxide for highly sensitive CEA and PSA biomarkers detection
    Barman, S. C.
    Hossain, M. F.
    Yoon, Hyosang
    Park, Jae Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 100 : 16 - 22
  • [2] Towards reliability enhancement of graphene FET biosensor in complex analyte: Artificial neural network approach
    Basu, Joyeeta
    Samanta, Nirmalya
    Jana, Sukhendu
    RoyChaudhuri, Chirasree
    [J]. MICROELECTRONICS RELIABILITY, 2018, 91 : 154 - 159
  • [3] Liquid gated ZnO nanorod FET sensor for ultrasensitive detection of Hepatitis B surface antigen with vertical electrode configuration
    Chakraborty, B.
    Ghosh, S.
    Das, N.
    RoyChaudhuri, C.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 122 : 58 - 67
  • [4] Chakraborty B., 2020, IEEE SENS J, V1748, P85
  • [5] An electrochemical DNA biosensor based on nitrogen-doped graphene/Au nanoparticles for human multidrug resistance gene detection
    Chen, Mei
    Hou, Changjun
    Huo, Danqun
    Bao, Jing
    Fa, Huanbao
    Shen, Caihong
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 85 : 684 - 691
  • [6] Paper-based chemiluminescence immunodevice for the carcinoembryonic antigen by employing multi-enzyme carbon nanosphere signal enhancement
    Chen, Ying
    Chu, Weiru
    Liu, Wei
    Guo, Xiaoyan
    Jin, Yan
    Li, Baoxin
    [J]. MICROCHIMICA ACTA, 2018, 185 (03)
  • [7] Highly sensitive electrochemical biosensor for glucose, DNA and protein using gold-polyaniline nanocomposites as a common matrix
    Chowdhury, Ankan Dutta
    Gangopadhyay, Rupali
    De, Amitabha
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 348 - 356
  • [8] Aptamer-based biosensors and nanosensors for the detection of vascular endothelial growth factor (VEGF): A review
    Dehghani, Sadegh
    Nosrati, Rahim
    Yousefi, Meysam
    Nezami, Alireza
    Soltani, Fatemeh
    Taghdisi, Seyed Mohammad
    Abnous, Khalil
    Alibolandi, Mona
    Ramezani, Mohammad
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 110 : 23 - 37
  • [9] Demuru S, 2019, 2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), P2464, DOI [10.1109/TRANSDUCERS.2019.8808497, 10.1109/transducers.2019.8808497]
  • [10] Hybrid structure of zinc oxide nanorods and three dimensional graphene foam for supercapacitor and electrochemical sensor applications
    Dong, Xiaochen
    Cao, Yunfa
    Wang, Jing
    Chan-Park, Mary B.
    Wang, Lianhui
    Huang, Wei
    Chen, Peng
    [J]. RSC ADVANCES, 2012, 2 (10) : 4364 - 4369