Precision lead tungstate crystal calorimeter for CMS at LHC

被引:14
|
作者
Zhu, RY [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
关键词
calorimeter; crystal; lead tungstate; monitoring; radiation damage; scintillator;
D O I
10.1109/TNS.2004.832804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A precision lead tungstate crystal calorimeter is being constructed by the CMS collaboration as a powerful tool to probe electroweak symmetry breaking and new physics in the LHC era. The status of calorimeter construction is reported. A crucial issue of maintaining crystal calorimetry precision in the expected radiation environment is elaborated.
引用
收藏
页码:1560 / 1567
页数:8
相关论文
共 50 条
  • [31] Quality of mass produced lead tungstate crystals
    Mao, RH
    Zhang, LY
    Zhu, RY
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 110 - 112
  • [32] Upgrade plans for hadron calorimeter in the CMS detector
    Dugad, Shashikant R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 264 - 266
  • [33] Design options for the upgrade of the CMS electromagnetic calorimeter
    Paramatti, R.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 : 995 - 1001
  • [34] A radiation damage and recovery study for lead tungstate crystals from BTCP and SIC
    Chen, Jianming
    Mao, Rihua
    Zhang, Liyuan
    Zhu, Ren-Yuan
    CALORIMETRY IN HIGH ENERGY PHYSICS, 2006, 867 : 252 - +
  • [35] Understanding the performance of CMS calorimeter
    Seema Sharma
    Pramana, 2007, 69 : 1069 - 1074
  • [36] Understanding the performance of CMS calorimeter
    Sharma, Seema
    PRAMANA-JOURNAL OF PHYSICS, 2007, 69 (06): : 1069 - 1074
  • [37] Stimulated Recovery of the Radiation Damage in Lead Tungstate Crystals
    Orsich, P.
    Dormenev, V.
    Brinkmann, K. -T.
    Korjik, M.
    Moritz, M.
    Novotny, R. -W.
    Zaunick, H. -G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (06) : 952 - 955
  • [38] Evaluation of mass-produced lead tungstate crystals
    Mao, RH
    Zhang, LY
    Zhu, RY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 406 - 410
  • [39] The ATLAS and CMS detectors at the LHC
    Fournier, Daniel
    Virdee, Tejinder
    COMPTES RENDUS PHYSIQUE, 2015, 16 (04) : 356 - 367
  • [40] Calibration strategy of CMS electromagnetic calorimeter
    Paramatti, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 22 - 23