Steady-state simulation of screw liquid chillers

被引:62
作者
Fu, L
Ding, GL
Su, ZJ
Zhao, GQ
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
[2] Tongji Univ, United Technol Res Ctr China Ltd, German Ctr, Shanghai 200092, Peoples R China
关键词
chiller; screw compressor; economizer; performance; model; simulation;
D O I
10.1016/S1359-4311(02)00084-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to predict the performance of screw liquid chillers in a wide range of configuration parameters and operating conditions, a steady-state simulation model is presented, which is suitable for non-economized and economized chillers. The model includes sub-models for key components, such as non-economized compressor, economized compressor, shell-and-tube condenser, expansion valve, and flooded evaporator. Sequential modular method and successive substitution methods are combined together to carry out the simulation of the chillers. The convergence properties of this simulation technique are also analyzed. The present model can predict the performance within +/-10% for large scale of cooling capacity including four specifications of non-economized chillers and three specifications of economized chillers. With the validated model, a sensitivity analysis on the economizer system is made. It is found that the cooling capacity of screw liquid chiller can be increased apparently by adding the economizer, but only when the volumetric ratio of the first stage internal compression is greater than a certain value, the economized screw liquid chiller can gain a higher COP than that of the non-economized one at the same time. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1731 / 1748
页数:18
相关论文
共 17 条
[1]  
[Anonymous], 1994, ASHRAE T
[2]  
*ASHRAE, 1996, ASHRAE HDB SYST EQ
[3]  
BAILEY MB, 1998, ASHRAE T, V104, P274
[4]   New approach to dynamic modelling of vapour-compression liquid chillers: artificial neural networks [J].
Bechtler, H ;
Browne, MW ;
Bansal, PK ;
Kecman, V .
APPLIED THERMAL ENGINEERING, 2001, 21 (09) :941-953
[5]   CONVENTIONAL CHILLER PERFORMANCES SIMULATION AND FIELD DATA [J].
BEYENE, A ;
GUVEN, H ;
JAWDAT, Z ;
LOWREY, P .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1994, 18 (03) :391-399
[6]   Heat transfer characteristics of boiling phenomenon in flooded refrigerant evaporators [J].
Browne, MW ;
Bansal, PK .
APPLIED THERMAL ENGINEERING, 1999, 19 (06) :595-624
[7]   An elemental NTU-ε model for vapour-compression liquid chillers [J].
Browne, MW ;
Bansal, PK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07) :612-627
[8]   Steady-state model of centrifugal liquid chillers [J].
Browne, MW ;
Bansal, PK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (05) :343-358
[9]  
BROWNE MW, 1998, ASHRAE T, V104, P474
[10]   CENTRIFUGAL CHILLERS - THERMODYNAMIC MODELING AND A DIAGNOSTIC CASE-STUDY [J].
GORDON, JM ;
NG, KC ;
CHUA, HT .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (04) :253-257