Effects of Implant Morphology on Rotational Stability During Immediate Implant Placement in the Esthetic Zone

被引:20
作者
Kan, Joseph Y. K. [1 ]
Roe, Phillip [1 ]
Rungcharassaeng, Kitichai [2 ]
机构
[1] Loma Linda Univ, Sch Dent, Dept Restorat Dent, Loma Linda, CA 92350 USA
[2] Loma Linda Univ, Sch Dent, Dept Orthodont & Dentofacial Orthoped, Loma Linda, CA 92350 USA
关键词
dental implants; immediate implants; immediate provisionalization; implant morphology; implant shape; implant stability; RESONANCE FREQUENCY-ANALYSIS; IN-VITRO; TITANIUM IMPLANTS; BONE; SURFACE;
D O I
10.11607/jomi.3885
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Primary implant stability is critical to achieving implant success, especially in a situation with immediate implant placement and provisionalization (IIPP) when bone quality and quantity are compromised. The purpose of this study was to examine the effects of implant morphology (tapered vs cylindric) and the final drill-implant diameter discrepancy (FD-IDD) of six implant systems on the incidence of rotational instability during IIPP in the esthetic zone. Materials and Methods: One hundred seventy-one implants in 112 patients were evaluated. Implants that exhibited inadequate resistance to the torque generated by the surgeon's hand during implant placement were classified as rotationally unstable. Results: The overall incidence of rotational instability for the tapered implants (1.1%) was significantly lower than that exhibited by the cylindric (nontapered) implants (20.5%). Among the cylindric implants, those with < 0.5 mm FD-IDD experienced a significantly higher incidence of rotational instability (36.6%) than groups with >= 0.5 mm FD-IDD. The incidence of rotational instability of cylindric implants with >= 0.5 mm FD-IDD was significantly greater than that of the tapered implants with a comparable FD-IDD. Conclusion: Within the confines of this study, the use of a tapered implant with an FD-IDD of >= 0.5 mm minimized the incidence of rotational implant instability for the IIPP procedure.
引用
收藏
页码:667 / 670
页数:4
相关论文
共 27 条
  • [1] Adell R., 1985, TISSUE INTEGRATED PR, P211
  • [2] DIFFERENCES IN IMPLANT STABILITY ASSOCIATED WITH VARIOUS METHODS OF PREPARATION OF THE IMPLANT BED: AN IN VITRO STUDY
    Ahn, Su-Jin
    Leesungbok, Richard
    Lee, Suk-Won
    Heo, Young-Ku
    Kang, Kyung Lhi
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06) : 366 - 372
  • [3] Algbamdi H, 2011, J ORAL MAXILLOFAC SU, V69, pe506
  • [4] Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
  • [5] EFFECT OF IMPLANT DESIGN ON INITIAL STABILITY OF TAPERED IMPLANTS
    Chong, Linus
    Khocht, Ahmed
    Suzuki, Jon B.
    Gaughan, John
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (03) : 130 - 135
  • [6] Dellinges M A, 1993, J Prosthodont, V2, P212, DOI 10.1111/j.1532-849X.1993.tb00411.x
  • [7] Effect of surgical techniques on primary implant stability and peri-implant bone
    Fanuscu, Mete I.
    Chang, Ting-Ling
    Akca, Kivanc
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (12) : 2487 - 2491
  • [8] Garber D A, 2001, Compend Contin Educ Dent, V22, P210
  • [9] Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading -: Successful vs. failing implants
    Glauser, R
    Sennerby, L
    Meredith, N
    Rée, A
    Lundgren, A
    Gottlow, J
    Hämmerle, CHF
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 428 - 434
  • [10] Glauser R, 2001, APPL OSSEOINTEGRATIO, V2, P6