Measurement of Gas Species, Temperatures, Coal Burnout, and Wall Heat Fluxes in a 200 MWe Lignite-Fired Boiler with Different Overfire Air Damper Openings

被引:18
作者
Jing, Jianping [1 ]
Li, Zhengqi [1 ]
Liu, Guangkui [1 ]
Chen, Zhichao [1 ]
Liu, Chunlong [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
UTILITY BOILER; COMBUSTION CHARACTERISTICS; INDUSTRIAL-SCALE; LOW-NOX; FURNACE;
D O I
10.1021/ef900249k
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Measurements were performed on a 200 MW,, wall-fired, lignite utility boiler. For different overfire air (OFA) damper openings, the gas temperature. g-as species concentration, coal burnout, release rates of components W, K and N). furnace temperature, and heat flux and boiler efficiency were measured. Cold air experiments for a single burner were conducted in the laboratory. The double-swirl flow pulverized-coal burner has two ring recirculation zones starting in the secondary air region in the burner. As the secondary air flow increases, the axial velocity of air flow increases, the maxima of radial velocity, tangential velocity and turbulence intensity all increase. and the swirl intensity of air flow and the size of recirculation zones increase slightly. In the central region of the burner, as the OFA damper opening widens, the gas temperature and CO concentration increase, while the O-2 concentration, NOx concentration, coal burnout, and release rates of components (C, H, and N) decrease, and coal particles ignite earlier. In the secondary air region of the burner, the O-2 concentration, NOx concentration, coal burnout, and release rates of components (C, H, and N) decrease, and the gas temperature and CO concentration vary slightly. In the sidewall region, the gas temperature, O-2 concentration, and NOx concentration decrease, while the CO concentration increases and the gas temperature varies slightly. The furnace temperature and heat flux in the main burning region decrease appreciably, but increase slightly in the burnout region. The NOx emission decreases from 1203.6 mg/m(3) (6% O-2) for a damper opening of 0% to 511.7 mg/m(3) (6% O-2) for a damper opening of 80% and the boiler efficiency decreases from 92.59 to 91.9%.
引用
收藏
页码:3573 / 3585
页数:13
相关论文
共 16 条
[1]  
ACRIVLELLIS M, 1978, DISA INFORM, V23, P11
[2]  
BLACK DL, 1996, COMBUST FIRE, V328, P19
[3]   LOCAL PARTICLE-VELOCITY, SIZE, AND CONCENTRATION MEASUREMENTS IN AN INDUSTRIAL-SCALE PULVERIZED COAL-FIRED BOILER [J].
BONIN, MP ;
QUEIROZ, M .
COMBUSTION AND FLAME, 1991, 85 (1-2) :121-133
[4]   LOCAL TEMPERATURE AND WALL RADIANT-HEAT FLUX MEASUREMENTS IN AN INDUSTRIAL-SCALE COAL FIRED BOILER [J].
BUTLER, BW ;
WEBB, BW .
FUEL, 1991, 70 (12) :1457-1464
[5]  
BUTLER BW, 1992, P COMBUST INST, V24, P1333
[6]   Experimental characterization of an industrial pulverized coal-fired furnace under deep staging conditions [J].
Costa, M. ;
Azevedo, J. L. T. .
COMBUSTION SCIENCE AND TECHNOLOGY, 2007, 179 (09) :1923-1935
[7]   Measurements of gas species, temperature, and char burnout in a low-NOx pulverized-coal-fired utility boiler [J].
Costa, M ;
Silva, P ;
Azevedo, JLT .
COMBUSTION SCIENCE AND TECHNOLOGY, 2003, 175 (02) :271-289
[8]   Combustion characteristics of a front-wall-fired pulverized-coal 300 MWe utility boiler [J].
Costa, M ;
Azevedo, JLT ;
Carvalho, MG .
COMBUSTION SCIENCE AND TECHNOLOGY, 1997, 129 (1-6) :277-293
[9]   Numerical and experimental investigation on the reduction of NOx emission in a 600 MW utility furnace by using OFA [J].
Fan, JR ;
Sun, P ;
Zheng, YQ ;
Ma, YL ;
Cen, KF .
FUEL, 1999, 78 (12) :1387-1394
[10]   New low NOx, low grade coal fired swirl stabilised technology [J].
Li, Z. Q. ;
Chen, Z. C. ;
Sun, R. ;
Wu, S. H. .
JOURNAL OF THE ENERGY INSTITUTE, 2007, 80 (03) :123-130