TE-Shave: Reducing Data Center Capital and Operating Expenses with Thermal Energy Storage

被引:11
作者
Zheng, Wenli [1 ]
Ma, Kai [1 ]
Wang, Xiaorui [1 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Data center; power shaving; power capping; thermal energy storage; capital expense; operating expense; POWER MANAGEMENT;
D O I
10.1109/TC.2015.2394381
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Power shaving has recently been proposed to dynamically shave the power peaks of a data center with energy storage devices (ESD), such that more servers can be safely hosted. In addition to the reduction of capital investment (cap-ex), power shaving also helps cut the electricity bills (op-ex) of a data center by reducing the high utility tariffs related to peak power. However, existing work on power shaving focuses exclusively on electrical ESDs (e.g., UPS batteries) to shave the server-side power demand. In this paper, we propose TE-Shave, a generalized power shaving framework that exploits both UPS batteries and a new knob, thermal energy storage (TES) tanks equipped in many data centers. Specifically, TE-Shave utilizes stored cold water or ice to manipulate the cooling power, which accounts for 30-40 percent of the total power cost of a data center. Our extensive evaluation with real-world workload traces shows that TE-Shave saves cap-ex and op-ex up to $2,668/day and $825/day, respectively, for a data center with 17,920 servers. Even for future data centers that are projected to have more efficient cooling and thus a smaller portion of cooling power, e.g., a quarter of today's level, TE-Shave still leads to 28 percent more savings than existing work that focuses only on the server-side power. TE-Shave is also coordinated with traditional TES solutions for further reduced op-ex, and integrated with processor throttling to cap the power draw (i.e., power capping). Our hardware testbed results show that TE-Shave can improve the system performance up to 23 percent.
引用
收藏
页码:3278 / 3292
页数:15
相关论文
共 43 条
[1]   Joint Optimization of Idle and Cooling Power in Data Centers While Maintaining Response Time [J].
Ahmad, Faraz ;
Vijaykumar, T. N. .
ACM SIGPLAN NOTICES, 2010, 45 (03) :243-256
[2]  
Ali AHH, 2013, PROCEEDINGS OF 2013 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), P153, DOI 10.1109/IRSEC.2013.6529735
[3]  
[Anonymous], 2012, Campos Survey Results
[4]  
[Anonymous], P IEEE GREEN COMP C
[5]  
[Anonymous], 2014, ICEBANK EN STOR MOD
[6]  
[Anonymous], IGCC 11
[7]  
[Anonymous], 2012, SUSTAINX SMART ENERG
[8]  
[Anonymous], 2005, P ANN C USENIX ANN T
[9]  
[Anonymous], 2010, 12 IEEE INT C THERM
[10]  
[Anonymous], 2005, BATTERY LIFE DEATH