Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source

被引:23
作者
Bouzid, Dounia [1 ,2 ]
Bert, Julien [1 ]
Dupre, Pierre-Francois [3 ]
Benhalouche, Saadia [1 ]
Pradier, Olivier [1 ,2 ]
Boussion, Nicolas [1 ,2 ]
Visvikis, Dimitris [1 ]
机构
[1] INSERM, UMR1101, LaTIM, Brest, France
[2] CHRU Brest, Dept Radiotherapy, Brest, France
[3] CHRU Brest, Dept Gynecol & Surg, Brest, France
关键词
DOSE CALCULATION; BRACHYTHERAPY; TARGIT; GPU; RADIOSURGERY; SIMULATIONS; PARAMETERS; MINIATURE; MODEL; CT;
D O I
10.3109/0284186X.2015.1016623
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intraoperative radiotherapy (IORT) is continuously gaining ground in cancer treatment. However, there is currently no planning system associated with these devices, which precludes patient-specific dose delivery optimization. The objective of this study was the development and validation of a Monte Carlo simulation (MCS)-based dosimetry platform using the Intrabeam system.Methods. After surgical resection of the tumor this system delivers a single dose fraction at the surface of an applicator irradiating the tumor bed through a 50 kV x-ray beam. The GATE MCS platform was used in this study combining the phase space obtained by modeling the x-ray source and the detailed modeling of the additional parts of the Intrabeam system. The model was validated by comparing simulated versus experimental measurements of depth dose curves (DDC) and isotropy. A clinical validation study was also carried out using patient computed tomography images.Results. The mean deviation between measured and simulated DDC was 2.9% 4.4% and 5.9% +/- 5.7% for the bare needle and the use of applicators, respectively. A good agreement with experimental measurements was also found in terms of dose isotropy with a maximum difference of 2.04% for the 40 mm diameter applicator. A patient study revealed a mean absolute deviation of 0.06 Gy between simulated and thermoluminescent dosimeters (TLD) measured skin doses.Conclusion. This study shows the potential of using the GATE MCS platform to model three-dimensional dose distributions of the Intrabeam system for use in IORT.
引用
收藏
页码:1788 / 1795
页数:8
相关论文
共 24 条
[1]   A new miniature x-ray device for interstitial radiosurgery: Dosimetry [J].
Beatty, J ;
Biggs, PJ ;
Gall, K ;
Okunieff, P ;
Pardo, FS ;
Harte, KJ ;
Dalterio, MJ ;
Sliski, AP .
MEDICAL PHYSICS, 1996, 23 (01) :53-62
[2]   Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation [J].
Beaulieu, Luc ;
Tedgren, Asa Carlsson ;
Carrier, Jean-Francois ;
Davis, Stephen D. ;
Mourtada, Firas ;
Rivard, Mark J. ;
Thomson, Rowan M. ;
Verhaegen, Frank ;
Wareing, Todd A. ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2012, 39 (10) :6208-6236
[3]   Geant4-based Monte Carlo simulations on GPU for medical applications [J].
Bert, Julien ;
Perez-Ponce, Hector ;
El Bitar, Ziad ;
Jan, Sebastien ;
Boursier, Yannick ;
Vintache, Damien ;
Bonissent, Alain ;
Morel, Christian ;
Brasse, David ;
Visvikis, Dimitris .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16) :5593-5611
[4]  
Chetty I, 2007, MED PHYS, V34, P36
[5]  
Chetty IJ, 2006, INT J RADIAT ONCOL, V65, P11
[6]   A Monte Carlo based source model for dose calculation of endovaginal TARGIT brachytherapy with INTRABEAM and a cylindrical applicator [J].
Clausen, Sven ;
Schneider, Frank ;
Jahnke, Lennart ;
Fleckenstein, Jens ;
Hesser, Juergen ;
Glatting, Gerhard ;
Wenz, Frederik .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (03) :197-204
[7]   A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO [J].
DeWerd, Larry A. ;
Ibbott, Geoffrey S. ;
Meigooni, Ali S. ;
Mitch, Michael G. ;
Rivard, Mark J. ;
Stump, Kurt E. ;
Thomadsen, Bruce R. ;
Venselaar, Jack L. M. .
MEDICAL PHYSICS, 2011, 38 (02) :782-801
[8]  
Dinsmore M, 1996, NEW MINIATURE XRAY S
[9]   Monte Carlo and experimental dosimetry of an 125I brachytherapy seed [J].
Dolan, James ;
Li, Zuofeng ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2006, 33 (12) :4675-4684
[10]   In Vivo Dosimetry for Single-Fraction Targeted Intraoperative Radiotherapy (TARGIT) for Breast Cancer [J].
Eaton, David J. ;
Best, Bronagh ;
Brew-Graves, Chris ;
Duck, Stephen ;
Ghaus, Tabasom ;
Gonzalez, Regina ;
Pigott, Katharine ;
Reynolds, Claire ;
Williams, Norman R. ;
Keshtgar, Mohammed R. S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05) :E819-E824