Optimized Three-Dimensional Fast-Spin-Echo MRI

被引:296
作者
Mugler, John P., III [1 ]
机构
[1] Univ Virginia, Sch Med, Dept Radiol & Med Imaging, Charlottesville, VA 22908 USA
关键词
RARE; fast spin echo; turbo spin echo; 3D FSE; 3D TSE; variable flip angles; FAST-FIELD ECHO; MAGNETIZATION-PREPARED; 3D-FLAIR; PERIPHERAL ARTERIAL-DISEASE; REFOCUSING FLIP ANGLES; T-INITIAL-EXPERIENCE; SINGLE-SLAB; MULTIPLE-SCLEROSIS; HIGH-RESOLUTION; ISOTROPIC RESOLUTION; CONVENTIONAL MRI;
D O I
10.1002/jmri.24542
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin-echo-based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin-echo imaging have become available from several MR-equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non-spatially selective radio-frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio-frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin-echo train, these techniques permit single-slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin-echo pulse sequences provide a robust and flexible approach for 3D spin-echo-based imaging with a broad range of clinical applications. J. Magn. Reson. Imaging 2014;39:745-767. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:745 / 767
页数:23
相关论文
共 127 条
[1]   Evaluation of Uterine Anomalies: 3D FRFSE Cube Versus Standard 2D FRFSE [J].
Agrawal, Garima ;
Riherd, Jody M. ;
Busse, Reed F. ;
Hinshaw, J. Louis ;
Sadowski, Elizabeth A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) :W558-W562
[2]   Diagnostic performance of CUBE MRI sequences of the knee compared with conventional MRI [J].
Ai, T. ;
Zhang, W. ;
Priddy, N. K. ;
Li, X. .
CLINICAL RADIOLOGY, 2012, 67 (12) :E58-E63
[3]   MR Imaging of Optic Neuropathy with Extended Echo-Train Acquisition Fluid-Attenuated Inversion Recovery [J].
Aiken, A. H. ;
Mukherjee, P. ;
Green, A. J. ;
Glastonbury, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) :301-305
[4]   The sensitivity of low flip angle RARE imaging [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :176-184
[5]   High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3 T vs. 1.5 T [J].
Arizono, Shigeki ;
Isoda, Hiroyoshi ;
Maetani, Yoji S. ;
Hirokawa, Yuusuke ;
Shimada, Kotaro ;
Nakamoto, Yuji ;
Shibata, Toshiya ;
Togashi, Kaori .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (01) :114-118
[6]   Assessment of the internal craniocervical ligaments with a new magnetic resonance imaging sequence: three-dimensional turbo spin echo with variable flip-angle distribution (SPACE) [J].
Baumert, Bernhard ;
Woertler, Klaus ;
Steffinger, Denise ;
Schmidt, Gerwin P. ;
Reiser, Maximilian F. ;
Baur-Melnyk, Andrea .
MAGNETIC RESONANCE IMAGING, 2009, 27 (07) :954-960
[7]   Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results [J].
Bink, A ;
Schmitt, M ;
Gaa, J ;
Mugler, JP ;
Lanfermann, H ;
Zanella, FE .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1104-1110
[8]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[9]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[10]   Trigeminal neuralgia: Assessment with T2 VISTA and FLAIR VISTA fusion imaging [J].
Cha, Jihoon ;
Kim, Sung Tae ;
Kim, Hyung-Jin ;
Choi, Jin Wook ;
Kim, Hye Jeong ;
Jeon, Pyoung ;
Kim, Keon Ha ;
Byun, Hong Sik ;
Park, Kwan .
EUROPEAN RADIOLOGY, 2011, 21 (12) :2633-2639