Relevant Aspects of Titanium and Zirconia Dental Implants for Their Fatigue and Osseointegration Behaviors

被引:7
|
作者
Aragoneses, Javier [1 ]
Lopez Valverde, Nansi [1 ]
Fernandez-Dominguez, Manuel [2 ]
Mena-Alvarez, Jesus [3 ]
Rodriguez, Cinthia [4 ]
Gil, Javier [5 ]
Manuel Aragoneses, Juan [3 ]
机构
[1] Univ Alcala, Dept Med & Med Specialties, Fac Med & Hlth Sci, Madrid 28871, Spain
[2] CEU San Pablo Univ, Dept Translat Med, Madrid 28660, Spain
[3] Univ Alfonso X El Sabio, Fac Dent, C Emilio Munoz 13, Madrid 28691, Spain
[4] Univ Federico Henriquez & Carvajal, Dept Dent, Santo Domingo 10106, Dominican Rep
[5] Univ Int Catalunya, Fac Med & Ciencias Salud, Bioengn Inst Technol, Sant Cugat Del Valles 08195, Spain
关键词
osseointegration; titanium; zircona; dental implants; bone index contact; histology; CORROSION BEHAVIOR; PRIMARY STABILITY; SURFACE MODIFICATIONS; SECONDARY STABILITY; THREAD GEOMETRY; IN-VITRO; BONE; ALLOYS; ROUGHNESS; CONTACT;
D O I
10.3390/ma15114036
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Osseointegration capacity and good mechanical behavior are key to the success of the dental implant. In many investigations, comparisons of properties are made using different dental implant designs and therefore the results can be influenced by the macrodesign of the dental implant. In this work, studies were carried out with the same dental implant model using different roughness and different materials-commercially pure titanium (grade 4) and zirconia. For this purpose, 80 smooth passivated titanium (Ti), 80 smooth zirconia (ZrO2), and 80 rough passivated titanium (Ti-R) dental implants were used. The samples were characterized by their roughness, wettability, surface energy, residual stresses, and fatigue behavior. The implants were implanted in minipigs for 4 and 12 weeks. The animals were sacrificed, and histological studies were carried out to determine the osseointegration parameters for each of the implantation times. Ti and ZrO2 dental implants have very similar wettability and surface energy properties. However, the roughness causes a decrease in the hydrophilic character and a decrease of the total surface energy and especially the dispersive component, while the polar component is higher. Due to the compressive residual stresses of alumina sandblasting, the rough dental implant has the best fatigue behavior, followed by Ti and due to the lack of toughness and rapid crack propagation the ZrO2 implants have the worst fatigue behavior. The bone index contact (BIC) values for 4 weeks were around 25% for Ti, 32% for ZrO2, and 45% for Ti-R. After 12 weeks the Ti dental implants increased to 42%, for Ti, 43% for ZrO2, and an important increase to 76% was observed for Ti-R implants. In vivo results showed that the key factor that improves osseointegration is roughness. There was no significant difference between ZrO2 and Ti implants without sandblasting.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] OSSEOINTEGRATION OF TITANIUM IMPLANTS
    CARLSSON, L
    ROSTLUND, T
    ALBREKTSSON, B
    ALBREKTSSON, T
    BRANEMARK, PI
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (04): : 285 - 289
  • [22] Fatigue behaviour of titanium dental endosseous implants
    Felli, Ferdinando
    Pilone, Daniela
    Scicutelli, Alessandro
    FRATTURA ED INTEGRITA STRUTTURALE, 2011, (18): : 14 - 22
  • [23] Significant improvement of the osseointegration of zirconia dental implants by HS-LEIS analysis
    Beekmans, H.
    Breitenstein, D.
    Brongersma, H. H.
    de Ridder, M.
    Tromp, Th J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (11-12): : 2172 - 2176
  • [24] Atomic Layer Deposition of Zirconia on Titanium Implants Improves Osseointegration in Rabbit Bones
    Kim, Hong-Joo
    Lee, Seon-Ki
    Kim, Hyun-Seung
    Kim, Won-Jae
    Ryu, Je-Hwang
    Ji, Min-Kyung
    Lim, Hyun-Pil
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2024, 19 : 5011 - 5020
  • [25] Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review
    Lopez-Valverde, Nansi
    Macedo-de-Sousa, Bruno
    Lopez-Valverde, Antonio
    Ramirez, Juan Manuel
    ANTIBIOTICS-BASEL, 2021, 10 (04):
  • [26] Improving osseointegration of dental implants
    Elias, Carlos Nelson
    Meirelles, Luiz
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (02) : 241 - 256
  • [27] CLINICAL ASPECTS OF OSSEOINTEGRATION IN JOINT REPLACEMENT - A HISTOLOGICAL STUDY OF TITANIUM IMPLANTS
    LINDER, L
    CARLSSON, A
    MARSAL, L
    BJURSTEN, LM
    BRANEMARK, PI
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04): : 550 - 555
  • [28] Zirconia dental implants as a different alternative to titanium: A literature review
    Chile, Jose
    Dolores, Antonio
    Espinoza-Carhuancho, Fran
    Alvitez-Temoche, Daniel
    Munive-Degregori, Arnaldo
    Barja-Ore, John
    Mayta-Tovalino, Frank
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2023, 13 (05): : 357 - 364
  • [29] Graphene for Zirconia and Titanium Composites in Dental Implants: Significance and Predictions
    Özcan M.
    Volpato C.A.M.
    Hian L.
    Karahan B.D.
    Cesar P.F.
    Current Oral Health Reports, 2022, 9 (3) : 66 - 74
  • [30] Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants
    Hanes, Brenda
    Feitosa, Sabrina
    Phasuk, Kamolphob
    Levon, John A.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 441 - 446